Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"Spinal implants."”.

  1. Spinal implants - the problems of debris

    … (UHMWPE), inherited from hip and knee implants, is a common choice in lumbar disc replacements. The wear debris from a Charité implant, tested in vitro, was characterised using computer vision techniques and machine learning. It was found that wear debris from this UHMWPE and metal …

    birmingham Download PDF for Spinal implants - the problems of debris (opens in a new tab)

  2. Development of osteoinductive coatings for spinal implants (fusion cages)

    … thesis aimed to improve the osteointegration of spinal fusion cages by developing an osteoinductive coating based on sol-gel chemistry and composed of TiO2 and Mg and Sr-substituted hydroxyapatite (sHAP). To reduce variability during the project, the in vitro culture of mesenchymal stem cells …

    whiterose Download PDF for Development of osteoinductive coatings for spinal implants (fusion cages) (opens in a new tab)

  3. Design and characterization of additively manufactured compliant features for spinal implants

    Spinal fusion is the most common surgical reconstruction method to treat spinal disorders. In this procedure, the degenerated disc is removed, with an interbody device inserted between two adjacent vertebral bodies to restore disc height. Eventually, bone will grow over the implant providing …

    waterloo Repository record for Design and characterization of additively manufactured compliant features for spinal implants (opens in a new tab)

  4. Compliant Structures Facilitate Less Invasive and Biomechanically Improved Lumbar Spinal Implants

    Implants used in lumbar spinal fusion and lumbar total disc replacement procedures have improved substantially over the years, however, the opportunity remains to improve either the adjustability, durability, motion, or minimally invasive characteristics which could aid in achieving optimal …

    byu Repository record for Compliant Structures Facilitate Less Invasive and Biomechanically Improved Lumbar Spinal Implants (opens in a new tab) Download PDF for Compliant Structures Facilitate Less Invasive and Biomechanically Improved Lumbar Spinal Implants (opens in a new tab)

  5. Investigating biomaterial fabrication in the domains of 3D food printing and spinal implants

    … in two different domains, 3D food printing and Spinal Implants. Two different approaches have been used for the two different investigations. For the purpose of 3D food printing, the effect of tuning the rheological properties of the ‘food ink’ was investigated. The approach was to change the …

    ttu Repository record for Investigating biomaterial fabrication in the domains of 3D food printing and spinal implants (opens in a new tab)

  6. Spinal Implant with Customized and Non-Linear Stiffness

    There is a need for spinal implants that have nonlinear stiffness to provide stabilization if the spine loses stiffness through injury, degeneration, or surgery. There is also a need for spinal implants to be customizable for individual needs, and to be small enough to be unobtrusive once …

    byu Repository record for Spinal Implant with Customized and Non-Linear Stiffness (opens in a new tab) Download PDF for Spinal Implant with Customized and Non-Linear Stiffness (opens in a new tab)

  7. Integrated Investigations of Lumbar Spine Biomechanics, Implant Fixation, and Design for Additive Manufacturing under Physiologic Loading

    Spinal implant loosening and migration are significant concerns following the surgical treatment of musculoskeletal spinal disorders because of the complex and highly variable loading experienced in the spine. During post-operative rehabilitation, the mechanical interface between the vertebral bone …

    waterloo Repository record for Integrated Investigations of Lumbar Spine Biomechanics, Implant Fixation, and Design for Additive Manufacturing under Physiologic Loading (opens in a new tab)

  8. Shape and function of the lumbar spine and the pelvis in the laboratory, in daily life and in the workplace

    … understanding the development of degenerative spinal diseases, for clinical planning of spinal surgeries, for the design of age- and gender specific LBP-therapies, for biomechanical testing of spinal implants as well as for optimizing prevention methods in the workplace. Method Using a …

    fu-berlin Repository record for Shape and function of the lumbar spine and the pelvis in the laboratory, in daily life and in the workplace (opens in a new tab)

  9. 흉요추부 골절의 수술적 치료 후 척추경 기기제거술의 효용성

    INTRODUCTION: Removal of posterior spinal implants after a successful spinal fusion is a common procedure in thoracolumbar fractures. However, there are still ongoing controversies regarding the advantages and drawbacks of the implant removal. We aimed to investigate the clinical and radiologic …

    ajou Repository record for 흉요추부 골절의 수술적 치료 후 척추경 기기제거술의 효용성 (opens in a new tab) Embargoed until 9999-12-31

  10. Water Absorption, Surface Roughness And Flexural Strength Assessment Of Peek With And Without Aging.

    … thermoplastic originally used in orthopedic and spinal implants, has recently been introduced into dentistry as an alternative denture base material. Its favorable properties include superior flexural strength, enhanced microhardness, low water absorption, chemical inertness, and reduced …

    uab Repository record for Water Absorption, Surface Roughness And Flexural Strength Assessment Of Peek With And Without Aging. (opens in a new tab)

  11. MORPHOMETRIC ANALYSIS OF THE SHEEP THORACOLUMBAR SPINE USING COMPUTED TOMOGRAPHY AND A COMPARISON WITH THE HUMAN CORRELATE

    … used as animal model for in vivo testing of new spinal implants as well as surgical procedures. Therefore, extensive knowledge of the precise morphometry and biomechanics features of sheep spine is crucial for experimental design and interpretation of results obtained in these trials. Little is …

    qucosa-diss

  12. Degeneration and mechanics of the segment adjacent to a lumbar spine fusion : a biomechanical analysis

    … degeneration (ASD) as a common complication of spinal fusion is believed by some clinicians and researchers to have roots in kinematic changes and altered loading at the intervertebral levels beside the fusion (i.e. adjacent). Dynamic spinal implants and minimally invasive surgeries were …

    ubc Repository record for Degeneration and mechanics of the segment adjacent to a lumbar spine fusion : a biomechanical analysis (opens in a new tab) Download PDF for Degeneration and mechanics of the segment adjacent to a lumbar spine fusion : a biomechanical analysis (opens in a new tab)

  13. Mapping the structural properties of the lumbosacral vertebral endplates

    … or damaged tissue. One failure mode of these implants is subsidence, in which the implant sinks into the adjacent vertebrae. This can lead to pain, deformity and nerve damage and can only be corrected through secondary surgery. Surgeons would like to know if there is some way to reduce the …

    ubc Repository record for Mapping the structural properties of the lumbosacral vertebral endplates (opens in a new tab) Download PDF for Mapping the structural properties of the lumbosacral vertebral endplates (opens in a new tab)

  14. Wear of PEEK All-Polymer Articulations for Cervical Spinal Disc Arthroplasty

    … disc disease (DDD) and disc herniation is spinal fusion, a process consisting of fusing two segments of the spine together. Arthroplasty treatments that preserve the natural motion of the spine are still in the early stages of development. Cervical disc arthroplasty (CDA) involves removal …

    waterloo Repository record for Wear of PEEK All-Polymer Articulations for Cervical Spinal Disc Arthroplasty (opens in a new tab)

  15. Investigation of a Robotic-Assisted Monocular Optical Tracking System for Navigated Spine Surgery using Modular Patient Reference Trackers

    On average, 15–18% of spinal implants are malpositioned or breach the cortical bone, leading to complications, revision surgeries, and increased healthcare costs. To improve surgical accuracy and patient outcomes, image-guided navigation systems have been developed to localize surgical instruments …

    waterloo Repository record for Investigation of a Robotic-Assisted Monocular Optical Tracking System for Navigated Spine Surgery using Modular Patient Reference Trackers (opens in a new tab)

  16. Simulation-based assessment for biomechanical behavior of scoliotic human thoracolumbar spine

    … spine FE models can be utilized to study the spinal biomechanics and the interaction between the spinal implant and spinal tissues in the following aspects: 1) Comparisons of pre- and post-operative scoliotic spines were made by investigating different biomechanical characteristics of ten …

    ttu Repository record for Simulation-based assessment for biomechanical behavior of scoliotic human thoracolumbar spine (opens in a new tab)

  17. Mechanical evaluation of pedicle screw fixation of the lumbar spine

    Pedicle screw fixation of the lumbar spine has been reported to increase fusion rates A biomechanical evaluation of four different pedicle screw implant systems, (AO. Rogozinski, TSRH and Wiltse). was performed to compare intrinsic device stiffness under conditions of flexion-compression and …

    njit Repository record for Mechanical evaluation of pedicle screw fixation of the lumbar spine (opens in a new tab)

  18. Poly(N-Isopropylacrylamide)-based scaffolds for tissue engineering applications

    … in tissue engineering applications, specifically spinal injury and nucleus pulposus replacement. Poly(N-isopropylacrylamide), denoted PNIPAAm, is a synthetic polymer with hydrophilic properties at room temperature, but above 32C the chains become hydrophobic and entangle to form physical …

    rowan Repository record for Poly(N-Isopropylacrylamide)-based scaffolds for tissue engineering applications (opens in a new tab)

  19. Delivery Optimization and Evaluation of Biomechanics of an Injectable Nucleus Pulposus Replacement Device

    … limited, jumping from physical therapy to major spinal fusion and total disc replacement surgery with little to no approaches in between. Furthermore, surgical treatments have not shown to be more effective than conservative treatments and reducing pain and disability over the long term. …

    rowan Repository record for Delivery Optimization and Evaluation of Biomechanics of an Injectable Nucleus Pulposus Replacement Device (opens in a new tab)

Page 1 of 2