Showing 1 to 9 of 9 for “"Spinal instrumentation"”.
-
Automated Manufacture of Spinal Instrumentation
… surgeries may include the use of multiple instrumentation devices including screws, wires, nuts, and rods. The instrumentation in most cases is implemented in its native form. However, the instrumentation rods must be contoured to a desired shape prior to fixation to the spine. The …
-
Evaluating toggle-out testing for pedicle screw failure prediction
… screw loosening is a common failure mode in spinal instrumentation, particularly in osteoporotic bone, where cancellous strength averages 0.944 MPa compared to 1.5-7.8 MPa in healthy bone. This study evaluated toggle-out testing for predicting pedicle screw failure and examined how material …
-
A Hybrid Modeling Workflow for Performing Finite Element Analyses Under In-Vivo Conditions
… models are commonly used to evaluate spinal loads due to difficulties associated with acquiring in-vivo measurements. Musculoskeletal (MSK) models can be used for performing simulations of movement by considering active structures such as muscles and simplified representations of joint …
-
A Novel Rat Model of Chronic Spinal Implant-Associated Infection
Spinal implant-associated infection is a rare but devastating complication. The prevalence of antibiotic-resistant pathogens like methicillin-resistant Staphylococcus aureus bacteria (MRSA) contribute to poorer outcomes for post-surgical spine infections due to their enhanced virulence and …
-
Design and development of a MEMS-based capacitive bending strain sensor and a biocompatible housing for a telemetric strain monitoring system.
Lumbar arthrodesis or spinal fusion is usually performed to relieve back pain and regain functionality from ruptured discs, disc degenerative disease, trauma and scoliosis. Metal rods are often fixed to the spine with screws or hooks, while fusion develops on the affected vertebrae. Fusion is …
-
Degeneration and mechanics of the segment adjacent to a lumbar spine fusion : a biomechanical analysis
… degeneration (ASD) as a common complication of spinal fusion is believed by some clinicians and researchers to have roots in kinematic changes and altered loading at the intervertebral levels beside the fusion (i.e. adjacent). Dynamic spinal implants and minimally invasive surgeries were …
-
Osteoporotic spine fixation : a biomechanical investigation
… including trauma, deformity and degeneration. Spinal instrumentation is often used to stabilize the spinal column and help facilitate the fusion. The main problems of using spinal instrumentation in elderly patients (many with osteoporosis) are loss of fixation due to loosening and adjacent …
-
Εμβιομηχανική της σπονδυλόμενης σπονδυλικής στήλης: μελέτη των εμφυτευμάτων της οσφυϊκής μοίρας της σπονδυλικής στήλης, με στόχο την αξιολόγηση - τεκμηρίωση της εμβιομηχανικής τους επάρκειας και αποτελεσματικότητας
… Thesis is the study and deeper understanding of spinal instrumentation mechanical behavior, as well as the investigation of a broad spectrum of parameters that influence their biomechanical efficiency. In particular the study was focused on pedicle screw internal fixation of the lumbar spine. For …