Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"Spinal unit"”.

  1. Dynamic, multiscale assessment of lumbar functional spinal unit biomechanics during physiologic motion

    … facet joints, the FCL is not only pivotal for spinal mechanics but is also a known contributor to LBP. An enhanced digital image correlation (DIC) protocol was developed to enable in situ strain data collection while preserving the mechanical integrity of specimens. This protocol was applied to …

    umn Repository record for Dynamic, multiscale assessment of lumbar functional spinal unit biomechanics during physiologic motion (opens in a new tab)

  2. The biology of the ovine functional spinal unit: facet cartilage and intervertebral disc

    … of the facet joints which increase with age. Spinal fusion is a common treatment that has been used for decades. The procedure involves the fusion of two vertebrae restricting motion in the functional spinal unit (FSU). Currently, tissue engineering methods are being researched to develop …

    whiterose Download PDF for The biology of the ovine functional spinal unit: facet cartilage and intervertebral disc (opens in a new tab)

  3. Development of a functional spinal unit for evaluation of sports and automotive protective equipment

    Globally, millions of spinal cord injuries (SCIs) and traumatic brain injuries (TBIs) occur annually [WHO, 2013], [Dewan, 2019], most commonly in vehicular crashes, falls and sports [Cripps, 2011], [Singh, 2014]. These injuries lead to paralysis, a decrease in mental health [DeVivo, 1991], [Losoi, …

    ubc Repository record for Development of a functional spinal unit for evaluation of sports and automotive protective equipment (opens in a new tab) Download PDF for Development of a functional spinal unit for evaluation of sports and automotive protective equipment (opens in a new tab)

  4. Proof‑of‑Concept Benchtop Testing of a Piezoelectric Spinal Implant Under Simulated Fusion Stiffness

    Spinal fusion is an ever more common approach to treat back pain and other spinal afflictions, especially in the lumbar region. Despite increased occurrence of the procedure, there is a lack of non-invasive, real-time, and accurate methods to monitor fusion progression. Piezoelectric implants are a …

    ku Repository record for Proof‑of‑Concept Benchtop Testing of a Piezoelectric Spinal Implant Under Simulated Fusion Stiffness (opens in a new tab)

  5. Development of ultrasound to measure deformation of functional spinal units in cervical spine

    … to measure the vertebral motion and functional spinal unit deformation. It is hypothesized that the time sequences of ultrasound imaging signals can be used to characterize the deformation of cervical spine functional spinal units in response to applied displacements and loading. Specifically, a …

    bu Repository record for Development of ultrasound to measure deformation of functional spinal units in cervical spine (opens in a new tab)

  6. Finite element analysis of vertebral end-plate failure under high dynamic axial load and its relation to age

    … to develop the analytical model of functional spinal unit with the intent of understanding the contribution of Intervertebral disc condition on the failure mechanism of End-plates under high rate dynamic loading, The condition of the disc for young people is healthy as compared to old person. …

    wichita-thes Repository record for Finite element analysis of vertebral end-plate failure under high dynamic axial load and its relation to age (opens in a new tab)

  7. Radio-Translucent 3-axis Mechanical Testing Rig for Spine in Micro-CT

    … a radio-translucent mechanical testing rig for spinal mechanical testing used in conjunction with a Shimadzu micro-CT scanner. Several tests were conducted to verify the feasibility of the rig design. Firstly, the rig was able to exert pure moment loading in the compression, flexion\extension …

    nus Repository record for Radio-Translucent 3-axis Mechanical Testing Rig for Spine in Micro-CT (opens in a new tab) Download file for Radio-Translucent 3-axis Mechanical Testing Rig for Spine in Micro-CT (opens in a new tab)

  8. Development of translational models for intervertebral disc degeneration using a comparative approach for canine and human patients

    … unique musculoskeletal tissues within functional spinal unit organs comprising the spinal column that distribute loads and allow complex movements for vertebrates. IVD degeneration has been closely associated with manifestations of symptomatic IVD disease (IVDD). IVDD spontaneously occurs in …

    missouri Repository record for Development of translational models for intervertebral disc degeneration using a comparative approach for canine and human patients (opens in a new tab)

  9. SAFETY AND EFFICACY OF INFLATABLE PENILE PROSTHESES IN PEOPLE WITH SPINAL CORD INJURY/DYSFUNCTION: A HOLISTIC TERTIARY REFERRAL CENTER WORKFLOW

    … where outcomes are influenced by all steps in a Spinal Unit: pre-operative optimization, surgical technique and post-operative management. 2. Aim of the study The primary objective of the study was to assess the safety of contemporary IPP implantation in selected men with SCI/D managed within a …

    milano Repository record for SAFETY AND EFFICACY OF INFLATABLE PENILE PROSTHESES IN PEOPLE WITH SPINAL CORD INJURY/DYSFUNCTION: A HOLISTIC TERTIARY REFERRAL CENTER WORKFLOW (opens in a new tab)

  10. Spinal Implant with Customized and Non-Linear Stiffness

    There is a need for spinal implants that have nonlinear stiffness to provide stabilization if the spine loses stiffness through injury, degeneration, or surgery. There is also a need for spinal implants to be customizable for individual needs, and to be small enough to be unobtrusive once …

    byu Repository record for Spinal Implant with Customized and Non-Linear Stiffness (opens in a new tab) Download PDF for Spinal Implant with Customized and Non-Linear Stiffness (opens in a new tab)

  11. Nurses' experience in caring for patients with traumatic spinal cord injury

    … when caring for patients with traumatic spinal cord injury that had neurological deficit at a spinal unit in Australia. The study used a hermeneutic phenomenological approach. Three registered nurses and three enrolled nurses with a broad range of experience were recruited and …

    adelaide Repository record for Nurses' experience in caring for patients with traumatic spinal cord injury (opens in a new tab)

  12. Development of an ultrasound system to measure in vivo dynamic cervical spine intervertebral disc mechanics

    … cervical collar at the C4-C5 functional spinal unit. A significant difference in response was detected when subjects wore an Army issued helmet with an attached weight to mimic night vision goggles. The results from these experiments will help develop ultrasound into an inexpensive, …

    bu Repository record for Development of an ultrasound system to measure in vivo dynamic cervical spine intervertebral disc mechanics (opens in a new tab)

  13. Establishing the Effect of Vibration and Postural Constraint Loading on the Progression of Intervertebral Disc Herniation

    … were created in in-vitro porcine functional spinal units using a herniation protocol of repetitive flexion/extension motions under modest compressive forces. After herniation initiation, functional spinal units were exposed to 8 different vibration and postural constraint loading protocols …

    waterloo Repository record for Establishing the Effect of Vibration and Postural Constraint Loading on the Progression of Intervertebral Disc Herniation (opens in a new tab)

  14. Biomechanical Testing on Cadaveric Spines for Different Treatments that Affect Lumbar Stability

    Stenosis is one of the most common causes for spinal surgery. Laminectomy decompression and fusion are surgical procedures prescribed for this condition. The intention of this work was to investigate the effects of a laminectomy decompression, followed by fusion, on a lumbar functional spinal unit …

    usf Repository record for Biomechanical Testing on Cadaveric Spines for Different Treatments that Affect Lumbar Stability (opens in a new tab)

  15. Utilization of Finite Element Analysis Techniques for Adolescent Idiopathic Scoliosis Surgical Planning

    … 10-18. Surgical correction and treatment of the spinal column is a costly and high-risk task that is consistently complicated by factors such as patient-specific spinal deformities, curve flexibility, and surgeon experience. The following dissertation utilizes finite element analysis to develop a …

    odu Repository record for Utilization of Finite Element Analysis Techniques for Adolescent Idiopathic Scoliosis Surgical Planning (opens in a new tab)

  16. The effect of cage positioning on lumbrosacral vertebral endplate failure in compression

    … the performance and patient outcome of any spinal arthrodesis surgery. To assess the best position to place an interbody fusion cage, a posterior interbody fusion construct was simulated. Specifically, the hypothesis to be tested was that two smaller, posterolaterally positioned interbody …

    ubc Repository record for The effect of cage positioning on lumbrosacral vertebral endplate failure in compression (opens in a new tab) Download PDF for The effect of cage positioning on lumbrosacral vertebral endplate failure in compression (opens in a new tab)

  17. Mechanical response of the porcine cervical spine to acute and repetitive anterior-posterior shear

    … element model of the porcine C3-C4 functional spinal unit was used to investigate the plausibility of hypotheses, developed from previous research and the findings of the first investigation for this thesis, surrounding alterations in measured ultimate shear failure tolerances as a function of …

    waterloo Repository record for Mechanical response of the porcine cervical spine to acute and repetitive anterior-posterior shear (opens in a new tab)

  18. Improvement of Ex Vivo Testing Methods for Spine Biomechanical Characterization

    … and biomechanical characterization of human spinal segments. The first was a literature review of existing testing methodology, the second examined common spine fixation procedures, and the third developed an improved fixation method. Spine biomechanical characterization is the primary …

    byu Repository record for Improvement of Ex Vivo Testing Methods for Spine Biomechanical Characterization (opens in a new tab) Download PDF for Improvement of Ex Vivo Testing Methods for Spine Biomechanical Characterization (opens in a new tab)

  19. Computational Modeling of Hard Tissue Response and Fracture in the Lower Cervical Spine under Compression Including Age Effects

    … accident (MVAs) victims experience traumatic spinal cord injuries (SCI), which are often associated with rollover accidents. Specifically, rollovers have the highest incidence rate of AIS2+ cervical spine injuries and more than half of the patients with SCIs demonstrated spine fractures with …

    waterloo Repository record for Computational Modeling of Hard Tissue Response and Fracture in the Lower Cervical Spine under Compression Including Age Effects (opens in a new tab)

  20. Finite Element and Probabilistic Analysis of Soft Tissue Structures of the Human Lumbar Spine

    … a representation of the intervertebral disc and spinal ligaments. Validation of these models are typically based on torque rotation data from a single subject or the models use average properties reported in literature. However, experimental testing reports variation up to 40% in ligament …

    denver Repository record for Finite Element and Probabilistic Analysis of Soft Tissue Structures of the Human Lumbar Spine (opens in a new tab)

Page 1 of 2