Results 1 to 20 of 24 for “"Splice region"”

  1. Behavior of the cast-in-place splice regions of spliced I-girder bridges

    Spliced girder technology continues to attract attention due to its versatility over traditional prestressed concrete highway bridge construction. Relatively limited data is available in the literature, however, for large-scale tests of post-tensioned I-girders, and few studies have examined the …

    texas Repository record for Behavior of the cast-in-place splice regions of spliced I-girder bridges (opens in a new tab)

  2. Performance of Reinforced Concrete Column Lap Splices

    … reinforced concrete columns with a lap splice of the longitudinal reinforcement near the base can induce high moment demands on the splice region when lateral loads are present on the structure. Code design specifications typically require a conservative splice length to account for …

    tamu Repository record for Performance of Reinforced Concrete Column Lap Splices (opens in a new tab)

  3. Structure-function studies of the sodium-calcium exchanger isoforms, NCX1 and NCX2

    … particularly in the eXchanger Inhibitory Peptide region (XIP) and the Ca2+ binding domains (CBD1/2), which have a direct impact on ionic regulation of the outward exchange currents. Recent structural studies of the Ca2+ binding domains of NCX1 suggest a mechanism by which Ca2+ binding would not …

    manitoba Repository record for Structure-function studies of the sodium-calcium exchanger isoforms, NCX1 and NCX2 (opens in a new tab)

  4. Studies on PDE4 cyclic AMP-specific phosphodiesterases

    … of four genes, each of which is alternatively spliced. Understanding the functional significance of the multiple species is crucial so as to enable the development of novel drugs to modulate their activities for the treatment of many disorders, including depression, asthma and arthritis. In …

    glasgow Repository record for Studies on PDE4 cyclic AMP-specific phosphodiesterases (opens in a new tab)

  5. Fiber-Based Modeling Strategy for Lap-Spliced Reinforced Concrete Columns Incorporating Bond-Slip Interaction

    … by bond interaction and confinement within the splice region. Particularly under cyclic loading, bond deterioration activates steel-concrete slip, leading to pinching behavior, strength degradation, and reduced energy dissipation capacity. These effects are particularly critical in older RC …

    alberta Repository record for Fiber-Based Modeling Strategy for Lap-Spliced Reinforced Concrete Columns Incorporating Bond-Slip Interaction (opens in a new tab)

  6. Θεραπεία ανεπάρκειας μήκους παράθεσης του διαμήκους οπλισμού υποστηλωμάτων παλαιών κατασκευών οπλισμένου σκυροδέματος

    … structures is the premature failure of the lap-spliced column longitudinal reinforcement. This brittle failure significantly affects the hysteretic response of the columns, which are structural members of the vertical bearing system, resulting in rapid degradation of lateral strength, ductility, …

    greece Repository record for Θεραπεία ανεπάρκειας μήκους παράθεσης του διαμήκους οπλισμού υποστηλωμάτων παλαιών κατασκευών οπλισμένου σκυροδέματος (opens in a new tab)

  7. Non-Contact Lap Splices in Dissimilar Concretes

    Non-contact lap splices placed within a single concrete placement are often used and have been studied in previous research projects. However, non-contact lap splices used with each bar in a different concrete placement such that there is a cold joint between the bars, have not been investigated. …

    vt Repository record for Non-Contact Lap Splices in Dissimilar Concretes (opens in a new tab)

  8. Seismic retrofit of bridge columns using fibre-reinforced concrete

    … used at that time and showed how poorly lap-spliced dowels perform under reversed cyclic loading. A retrofitting technique (Griezic, 1996) that employs an added footing block, which moves the location of expected plastic hinging to the top of the lap splice and adds confinement to the lower …

    mcgill Repository record for Seismic retrofit of bridge columns using fibre-reinforced concrete (opens in a new tab)

  9. Retrofit of deficient lap splice with post-installed anchors

    … efficient retrofit solutions, with deficient lap splices being one of many research areas. A possible method to increase the capacity of deficient lap splices is to use post-installed undercut anchors. These anchors function as active confinement in the splice region, potentially allowing members …

    texas Repository record for Retrofit of deficient lap splice with post-installed anchors (opens in a new tab)

  10. Bond of LAP-spliced bars in self-compacting concrete

    … In this study, 6 full-scale concrete beams spliced at the mid-span were tested under two-point symmetrical loading. Test variables were bottom cover, side cover, free spacing between longitudinal reinforcement, lap-splice length and presence of transverse reinforcements within the lap-splice …

    metu Repository record for Bond of LAP-spliced bars in self-compacting concrete (opens in a new tab)

  11. Use of CFRP to provide continuity in existing reinforced concrete members subjected to extreme loads

    … discontinuity) and poorly detailed lap splices in columns (vertical discontinuity). The objective of this study was to develop rehabilitation methods using CFRP to provide continuity of reinforcement in existing structures. To develop the rehabilitation methods, two separate experimental …

    texas Repository record for Use of CFRP to provide continuity in existing reinforced concrete members subjected to extreme loads (opens in a new tab)

  12. Analysis of the shear behavior of prestressed concrete spliced girders

    Implementation of the spliced girder technology in bridges has been growing in recent years. Increased girder lengths can now be realized by splicing shorter precast segments to produce a long span. The research conducted in this dissertation is focused on an evaluation of spliced girders using a …

    texas Repository record for Analysis of the shear behavior of prestressed concrete spliced girders (opens in a new tab)

  13. IL1RL2 in immunity and intestinal homeostasis-Insights from patients with VEO-IBD

    … missense mutations (c.[952A>G];[965A>C]) and splice region mutation (c.1298-4C>T) in IL1RL2 (Interleukin 1 receptor-like 2) as a novel risk factor for VEO-IBD. This assessment purposed to enlighten the molecular mechanisms of IL1RL2 deficiency in macrophages and epithelial cells. The study …

    lmu-germany Repository record for IL1RL2 in immunity and intestinal homeostasis-Insights from patients with VEO-IBD (opens in a new tab)

  14. Molecular analysis of the prothrombin gene in two patients

    … Primers were designed to include the intron/exon splice junctions and approximately 100 bp 5’ to exon 1 in the amplification reactions. To facilitate directional cloning, restriction sites were incorporated into the primers. In this way, each region could then be analyzed by DNA sequencing. The …

    ubc Repository record for Molecular analysis of the prothrombin gene in two patients (opens in a new tab)

  15. Splice tests of plain steel bars in concrete

    Fifteen splice specimens reinforced with plain steel bars, including three specimens instrumented with both steel and concrete strain gauges, were tested under monotonically applied four-point loading to develop a database of reliable bond test results and contribute to the development of a …

    sask Repository record for Splice tests of plain steel bars in concrete (opens in a new tab)

  16. CFRP strengthening of RC beams with corroded lap spliced steel bars

    … on the bond strength of corroded tension lap splices under static loading. The beams were 200mm wide by 300mm high by 2000mm. Each beam was reinforced on the tension side with two steel bars (2 M 15 or 2 M20 steel bars) spliced at mid span in the constant moment region. The nominal concrete …

    waterloo Repository record for CFRP strengthening of RC beams with corroded lap spliced steel bars (opens in a new tab)

  17. The effects of casting position and bar shape on the lap length of plain bars in concrete

    Eighteen splice specimens were tested under four-point loading as part of a larger experimental investigation to study the behaviour of lap spliced plain steel bars in reinforced concrete specimens. Three of the specimens were instrumented with strain gauges adhered to the reinforcement and the …

    sask Repository record for The effects of casting position and bar shape on the lap length of plain bars in concrete (opens in a new tab)

  18. Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction

    … average, the reinforcing bars in non-contact lap splices, where the lapped bars are located in adjacent cells, only develop 71% of the tensile resistance of spliced bars which are in contact. An experimental program was therefore initiated to design and evaluate remedial measures which can …

    sask Repository record for Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction (opens in a new tab)

  19. Performance of large size reinforced concrete beams containing a lap splice subjected to fatigue loads

    … of reinforced concrete beams containing lap splices. The knowledge acquired from this research has led to recommendations for changes in how seismic and static loading of lap splices are handled. For splices subjected to high cycle low stress load patterns (fatigue loading) current design of …

    sask Repository record for Performance of large size reinforced concrete beams containing a lap splice subjected to fatigue loads (opens in a new tab)

  20. Alternative Placement of Vertical Reinforcement in Slender Masonry Walls

    … had just yielded, with visible damage in a lap-splice region, indicated a bond-loss mechanism at ultimate. While results showed performance improvements, they also indicate that further research and refinement of design guidelines is needed. The potential loss of bonding when reinforcing bars …

    alberta Repository record for Alternative Placement of Vertical Reinforcement in Slender Masonry Walls (opens in a new tab)