Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 170 for “"Splices"”.

  1. Performance of Reinforced Concrete Column Lap Splices

    Cantilevered reinforced concrete columns with a lap splice of the longitudinal reinforcement near the base can induce high moment demands on the splice region when lateral loads are present on the structure. Code design specifications typically require a conservative splice length to account for …

    tamu Repository record for Performance of Reinforced Concrete Column Lap Splices (opens in a new tab)

  2. Non-Contact Lap Splices in Dissimilar Concretes

    Non-contact lap splices placed within a single concrete placement are often used and have been studied in previous research projects. However, non-contact lap splices used with each bar in a different concrete placement such that there is a cold joint between the bars, have not been investigated. …

    vt Repository record for Non-Contact Lap Splices in Dissimilar Concretes (opens in a new tab)

  3. Seismic behavior of bridge pier column lap splices

    Inadequate flexural strength and ductility, or shear strength, of concrete bridge columns have resulted in collapse or severe damage of a number of California bridges in recent moderate earth-quakes. In general, these bridges were designed prior to the new seismic design methods which were …

    uiuc Repository record for Seismic behavior of bridge pier column lap splices (opens in a new tab)

  4. Confinement Limits For Tensile Lap Splices Under Static Loading

    ABSTRACT In tension lap splices, the benefit provided to the lap by stirrups placed to intercept cracking due to bond splitting action is recognized by the American Concrete Institute (ACI 318-89) and the design recommendations of the ACI Committee 408, on which the American code provisions are …

    sask Repository record for Confinement Limits For Tensile Lap Splices Under Static Loading (opens in a new tab)

  5. Mechanical Bar Splices for Accelerated Construction of Bridge Columns

    … congestion in joints. Recently, mechanical bar splices, which are also referred to as bar couplers, have been used to connect precast members to accelerate construction of concrete bridges and buildings. Current codes prohibit the use of couplers in the plastic hinge regions of bridge columns in …

    sdstate Repository record for Mechanical Bar Splices for Accelerated Construction of Bridge Columns (opens in a new tab)

  6. Hooked Bar Anchorages and their Use in Noncontact Lap Splices

    Lap splices are used in reinforced concrete structures to transfer tension forces across discontinuous reinforcing bars to allow for continuity of load path in structural elements. Lap splices of straight reinforcing bars present a number of disadvantages when used in connections of large precast …

    vt Repository record for Hooked Bar Anchorages and their Use in Noncontact Lap Splices (opens in a new tab)

  7. Performance of tension lap splices with MMFX high strength reinforcing bars

    … of 80 ksi and 75 ksi. Limited data exists for splices failing at bar stresses greater than 75-80 ksi, and no data exists for splices failing at bar stresses greater than 120 ksi — a stress attainable by MMFX reinforcement. To determine the adequacy of the development length equations in the ACI …

    texas Repository record for Performance of tension lap splices with MMFX high strength reinforcing bars (opens in a new tab) Restricted access

  8. High cycle (fatigue) resistance of reinforced concrete beams with lap splices

    … for reinforced concrete beams containing lap splices has been mainly aimed at preventing failures due to static (monotonic) loading, or low cycle, high intensity (seismic) loading. However, little consideration has been given in these standards or in previous research to the performance of lap …

    sask Repository record for High cycle (fatigue) resistance of reinforced concrete beams with lap splices (opens in a new tab)

  9. Non-linear modeling parameters for reinforced concrete columns with inadequate lap splices

    The Structural Engineering Institute of the American Society of Civil Engineers (ASCE/SEI) publishes a Standard used across the United States and in many countries for Seismic Evaluation and Retrofit of Existing Buildings (ASCE/SEI 41-13). The Standard defines strength capacities of structural …

    texas Repository record for Non-linear modeling parameters for reinforced concrete columns with inadequate lap splices (opens in a new tab)

  10. The anchorage behavior of headed reinforcement in CCT nodes and lap splices

    … using full scale tests of CCT nodes and lap splices. The mechanics of the anchorage behavior were observed and recorded to evaluate the manner in which the capacity of a headed bar is developed. The measured data were used to evaluate existing models of headed reinforcement anchorage as well …

    texas Repository record for The anchorage behavior of headed reinforcement in CCT nodes and lap splices (opens in a new tab)

  11. Effects of Mechanical Bar Splices on Seismic Performance of Reinforced Concrete Buildings

    Mechanical bar splices, which are commonly referred to as couplers, are currently used in reinforced concrete structures to directly connect steel bars in lieu of conventional lap splicing. With proper detailing, couplers can be utilized to connect precast beams and columns to accelerate the …

    sdstate Repository record for Effects of Mechanical Bar Splices on Seismic Performance of Reinforced Concrete Buildings (opens in a new tab)

  12. Effectiveness of Alternative Reinforcing Strategies for Non-Contact Hooked Bar Lap Splices

    … and develop design guidance for hooked bar lap splices. This project did not investigate three parameters: the number of lap splices, the placement of transverse reinforcement, and the addition of steel fibers in the closure joint. For this thesis, 15 beam-splice specimens were tested in 4 …

    vt Repository record for Effectiveness of Alternative Reinforcing Strategies for Non-Contact Hooked Bar Lap Splices (opens in a new tab)

  13. Non-Contact Lap Splices in Geometrically Dissimilar Bridge Column to Drilled Shaft Connections

    Contact lap splices are widely used for the construction of reinforced concrete structures. But, it is often required to provide a reinforcing steel splicing arrangement with non-contact lap splices due to the limitation of internal space or geometric irregularity for the connection of non-circular …

    houston Repository record for Non-Contact Lap Splices in Geometrically Dissimilar Bridge Column to Drilled Shaft Connections (opens in a new tab)

  14. The SnapLocX Connection: A Novel Approach to Interlocking Steel W-Shape Column Splices

    Column splices are critical components in steel structures above three stories that ensure the stability and integrity of the building framework. Splices are required when standard column lengths are insufficient for the design height of the structure. Standard erection practice for W-shape column …

    washington Repository record for The SnapLocX Connection: A Novel Approach to Interlocking Steel W-Shape Column Splices (opens in a new tab)

  15. Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction

    … average, the reinforcing bars in non-contact lap splices, where the lapped bars are located in adjacent cells, only develop 71% of the tensile resistance of spliced bars which are in contact. An experimental program was therefore initiated to design and evaluate remedial measures which can …

    sask Repository record for Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction (opens in a new tab)