Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Spot scanning"”.
-
Low-dose radiography by flying x-ray spot scanning (Lisar).
… radiography can be achieved with flying x-ray spot scanning. An apparatus named 'LISAR', for Low-Intensity Scanning Apparatus for Radiography, was designed and built for the purpose of producing low-dose radiographs. The x-ray photon detection system uses a sodium iodide (thallium activated) …
-
Commissioning And Validation Of Analytical And Monte Carlo Based Dose Calculation Algorithms For Proton Spot Scanning
Purpose: Accurate dose calculation is one of the most necessary components of radiation therapy. While the commercially available photon dose calculation algorithm offerings have improved considerably in last decade, proton dose calculations are still performed using the analytical dose calculation …
-
Sensor Embedding And Thermal Monitoring Strategies For Laser-Foil-Printing Additive Manufacturing
… To stabilize the molten melt pool, a discrete spot scanning strategy was implemented. The fabricated parts were subjected to detailed analysis, including melt pool dimension evaluation using scanning electron microscopy (SEM) and residual stress assessment using X-ray diffraction (XRD). …
-
ラジオアクティブ(11C)ビームを用いたスポットスキャン医療照射法の開発研究
要旨のタイトル「Spot Scanning Using Radioactive 11C Beams for Heavy-ion Radiotherapy」とあり
-
Evaluation von dosisoptimierten Protokollen für die Computertomographie-gestützte zervikale und lumbale periradikuläre Infiltrationstherapie
… eine Planung mit vier Einzelschichtaufnahmen (Spot Scanning) und anschließend die fluoroskopische Na-delpositionierung durchgeführt. Die Fluoroskopie sah bei aktiviertem iterativen Re-konstruktionsalgorithmus eine Basiseinstellung mit einer Röhrenspannung von 80 kV (zervikale Wirbelsäule) oder …
-
The Development and Implementation of An Anthropomorphic Head Phantom For The Assessment of Proton Therapy Treatment Procedures
… plans, proton passive scattering and proton spot scanning, were created. Thermoluminescent dosimeters (TLDs) and film were loaded into the phantom dosimetry insert. Each treatment plan was delivered three separate times. Each treatment plan passed our 5%/3mm criteria, with a reproducibility …
-
Rapid Two-Photon Holographic Scan Microscopy with Individual Quantum Dots and Its Applications in Biological Samples
… are shown: 1) widefield, 2) diffraction-limited spot scanning with a single rastered spot, or 3) a multi-point excitation scheme employing a 9 × 9 matrix hologram that increases the scan rate by 80 fold. An array detector (EMCCD camera) was also used as a detector for 2-photon scanning …
-
Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy
… and used to create passive scattering and spot scanning treatment plans. Each plan was delivered three times at a dose of 6 Gy. The following attributes were evaluated: absolute dose agreement, distal range, field width, junction match and right/left dose profile alignment. The hypothesis …
-
Image-Guided Proton Therapy For Online Dose-Evaluation and Adaptive Planning
… Finally, we assessed a potential method to adapt spot scanning proton treatment plan beam parameters to account for anatomical changes. This range-adaptive method adjusts the proton beam directly to match the new range to anatomy in the treatment-time image. Using this technique, we were able to …
-
CHROMATOGRAPHIC-PHOTODENSITOMETRIC QUANTITATION OF THE SOLANACEOUS ALKALOIDS
… the absorbance varies considerably throughout a spot and that the geometry of "'inhume spots may vary considerably from that of standard spots be- cause of the greater complexity of unknown samples. It was felt that the only way to reduce errors of non-linearity due to non-uniform distribution of …
-
3D Scintillator Detector Quenching Characterization For Scanning Proton Beams
<p>Proton pencil beam scanning is becoming the standard treatment delivery technique for proton therapy centers. Scanned proton pencil beams provide a highly conformal dose distribution. The complex dose distribution poses challenges for quality assurance measurements leading to sophisticated …
-
Verification of The Clinical Implementation of The Respiratory Gated Beam Delivery Technique With Synchrotron-Based Proton Irradiation
… gating technique in both passive scattering and scanning delivery mode. Our hypothesis for the study was that optimization of the parameters of synchrotron operation and respiratory gating can lead to greater efficiency and accuracy of respiratory gating for all modes of synchrotron-based proton …
-
Ultra-fast treatment delivery to enhance the potential of proton therapy
… the most used method to deliver the dose is spot scanning or pencil beam scanning (PBS). PBS typically provides improved dose conformity and healthy tissue sparing when compared to equivalent photon plans. However, PBS is especially prone to uncertainties caused by anatomical changes and …