Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"Spray Column"”.
-
Liquid-liquid extraction in a spray column
… or circulation in the continuous phase of a spray type liquid-liquid extraction tower. Concentration profiles of both continuous and dispersed phases were obtained by internal sampling. Mass transfer data are presented for the transfer of acetic acid between water and methyl isobutyl ketone …
-
Characterization of axial mixing in a spray column
Electronic Thesis or Dissertation
-
Sampling of the phases within a liquid-liquid extraction spray column
… techniques in a liquid-liquid extraction spray column using first a bell-shaped and a hook-shaped probe for the dispersed phase and for the continuous phase respectively. Later a piston method was attempted for the dispersed phase. The main interest in this research was the point …
-
Improvement of Spray Column Performance for Post-Combustion Carbon Dioxide Capture using different Column Configurations
… Based on the findings from literature, a spray column is seen to be a promising alternative, however, needs further design improvements to achieve a comparable gas-liquid contact efficiency. Recent work in this field indicates that for a spray column, the mass transfer coefficient is …
-
Design, construction, and operation of a piston type sampler for a liquid-liquid extraction spray column
… constructed to sample the dispersed phase of a spray liquid-liquid extraction tower. The aim was to check a previous method of sampling the dispersed phase. This method depended on the use of a long probe which descended into the column from above and through which samples were removed by …
-
Axial dispersion of the continuous phase in liquid-liquid extraction spray columns and internal sampling techniques
… isobutyl ketone) in a liquid-liquid extraction spray column. The dispersed phase sample can be withdrawn from the column by the plastic cup probe without being contaminated with the continuous phase water. For runs in which the mass transfer is from the continuous phase to the dispersed phase, …
-
An exploratory study of the mechanism of coalescence of drop pairs
… drop coalescence in a liquid-liquid extraction column has been used to study the mechanism of coalescence taking place between drop pairs undergoing mass transfer0 The direction of diffusion studied was mainly from the dispersed to the continuous phase. The density of the dispersed phase was …
-
Drop size distribution in a liquid-spray extraction column
… of drop size distribution was carried out in a spray column by photographing the drops either through a round column or through a short square column inserted into the round column. A close-up photography technique was used and optical distortion of the round column taken into account. The drops …
-
Individual mass transfer resistances in liquid-liquid extraction
… isobutyl ketone-water system in a 4-inch I.D. spray column. Column height was varied from one to four feet. Individual film resistances (as H.T.U.) and individual capacity coefficients (ka) were measured by passing the two partially miscible liquids counter - currently through the column. The …
-
A numerical investigation of performance and optimization trends of direct contact heat exchangers
… to describe some very specific and limited DCHX spray-column configurations. Changes to the initial model are proposed to reflect more accurately the physics of the flows found in both two- and three-phase DCHXs. In addition, generalizations are incorporated into the model to be able to analyze a …
-
Thermal management of the copper-chlorine cycle for hydrogen production: analytical and experimental investigation of heat recovery from molten salt
… a direct contact heat recovery process (i.e. a spray column) and an indirect contact heat recovery process (i.e. a double-pipe heat exchanger). Characteristics of a spray column, in which recovered heat from molten CuCl is used to produce superheated steam, are presented. Decreasing the droplet …
-
The analysis of a three-phase direct contact heat transfer experiment
… phase holdup and gas void fraction in the column. The analysis appears to indicate that increases in dispersed phase holdup and gas void fraction have an adverse effect on the boiling efficiency of the direct contact heat exchanger.</p> <p>Volumetric and surface area heat transfer …
-
Back-mixing in liquid-liquid extraction spray columns
… continuous phase was studied in liquid-liquid spray columns of various geometries, for various flowrates of the two phases, and for various drop size distributions. The dispersion or eddy diffusion model was used to characterize the axial mixing of the continuous phase. Axial concentration …
-
An experimental investigation of direct contact three phase boiling heat transfer
… and vapor were contacted in a counterflow spray column with only differential increases in vapor quality. Experiments yielded vertical temperature profiles, flow rates of the phases, liquid holdups, pressure drops, and a characterization of flow patterns. A micro—computer was utilized for …
-
Mass Transfer Characteristics of Large Oscillating Drops
… reviewed. A thermostatically-controlled spray column, provided with mirrors, was used to study the hydrodynamics and mass transfer characteristics of single large oscillating drops and drop pairs ascending through water. Up to 25%w/w of acetone was dissolved in toluene, which facilitated …
-
Planejamento experimental aplicada a um novo separador líquido-líquido utilizado no tratamento de águas residuais contaminadas com petróleo
… features of conventional mixer-settler and spray column type. The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the …
-
Solvent extraction of lubricating oils
… in a one-inch in nominal diameter pyrex glass spray column using various ratios of furfural to oil. The oil was passed in tiny drops through the 9.75 feet high column countercurrent to the furfural flow which was down through the column. The average number of drops formed and the time of …
-
Návrh sprejové kolony pro zachycení CO2
Tato práce se zabývá způsoby, jakými lze zachytit CO2 vznikající v energetice a průmyslových závodech a omezit tím jeho koncentraci v atmosféře. Práce se věnuje především technologii čištění spalin po spalování pomocí sprejových kolon. Po rešerši separačních procesů a již provedených experimentech …
-
Zachycení CO2 ve sprejové koloně za použití různých atomizačních technik
Zachytávání oxidu uhličitého (CO2) může být klíčovým krokem v boji proti globálním změnám klimatu. Jednou z perspektivních technologií pro záchyt CO2 je sprejová kolona. Tato diplomová práce zkoumala její potenciál prostřednictvím rešerše dostupné literatury a experimentů na laboratorním modelu …
Page 1 of 2