Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 95 for “"Square Wave Voltammetry"”.

  1. Fast Fourier transform square wave voltammetry

    … as a.unique digital data handling tool for square wave voltammetry. Theoretical square wave voltammogra.ms were examined to study the effect of experimental parameters in the spatial frequency domain. A new method was developed to determine truncation frequencies. A₀, the first spatial …

    vt Repository record for Fast Fourier transform square wave voltammetry (opens in a new tab)

  2. Square-wave voltammetry detection for capillary electrophoresis

    … this instrumentation, an ECD system based on square-wave voltammetry was developed (CE-SWV). Detection limits obtained with CE-SWV for neurotransmitters (150 nM, S/N = 3) were comparable to those obtained using more fragile and complex amperometric CE detection systems. While CE-SWV worked …

    sask Repository record for Square-wave voltammetry detection for capillary electrophoresis (opens in a new tab)

  3. Electrochemical TiO2 Semiconductor Analysis by Square Wave Voltammetry

    … an electrochemical characterization technique, square wave voltammetry (SWV) can provide significantly less background current and greater sensitivity than its linear counterpart as a result of sampling the current at the end of each pulse. This is beneficial for the accurate measurement and …

    toronto-retro Repository record for Electrochemical TiO2 Semiconductor Analysis by Square Wave Voltammetry (opens in a new tab)

  4. Diagnostic criteria of electrochemical reaction mechanisms using cyclic square wave voltammetry

    … determine its diagnostic criteria using cyclic square wave voltammetry. The reactions for each mechanism are written containing both the electroactive and electroinactive species. From these reactions and appropriate diffusion equations and boundary conditions, the expressions of concentrations …

    gatech Repository record for Diagnostic criteria of electrochemical reaction mechanisms using cyclic square wave voltammetry (opens in a new tab)

  5. Square Wave Voltammetry Detection and CD Spectroscopy Structural Characterization of 5- Methyl Cytosine-Containing Oligomeric DNA Sequences

    … Detection of the DNA took place using square wave voltammetry via reduction of C12Viologen, which has been previously shown to bind to DNA in a structure specific manner. MgCl2 induced structural changes in the DNA, which were related to the amount of cytosine methylation featured in …

    ecu Repository record for Square Wave Voltammetry Detection and CD Spectroscopy Structural Characterization of 5- Methyl Cytosine-Containing Oligomeric DNA Sequences (opens in a new tab)

  6. Complementary Analysis of Colorectal Cancer-Associated DNA Using Square Wave Voltammetry and LC-MS/MS in a Murine Model

    … under conditions of mitochondrial dysfunction. Square wave voltammetry (SWV) at layer-by-layer modified electrodes with immobilized DNA allowed detection of guanine oxidation changes catalyzed by the electrochemical mediator, Ru(byp)32+. Peak current differences of tumor samples compared to …

    ecu Repository record for Complementary Analysis of Colorectal Cancer-Associated DNA Using Square Wave Voltammetry and LC-MS/MS in a Murine Model (opens in a new tab) Embargoed until 2027-07-01

  7. Complementary Square Wave Voltammetry and LC-MS/MS Analysis to Elucidate Induced Damaged and Mutated Mitochondrial and Nuclear DNA from Biological Organisms

    … variations, and damage in biological systems. Square wave voltammetry (SWV) at pyrolytic graphite electrodes with immobilized DNA allowed detection of guanine oxidation peaks catalyzed by Ru(bpy)32+. Peak current differences compared to wild-type (WT) or unaltered samples indicated DNA …

    ecu Repository record for Complementary Square Wave Voltammetry and LC-MS/MS Analysis to Elucidate Induced Damaged and Mutated Mitochondrial and Nuclear DNA from Biological Organisms (opens in a new tab)

  8. Elektrocheminė paracetamolio analizė /

    … by electrochemical analysis methods – cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (ChA) methods were used for this purpose. With the help of CV, it was observed that the reactions take place due to diffusion, therefore, using the Randles - Ševčik equation, the …

    vilnius Repository record for Elektrocheminė paracetamolio analizė / (opens in a new tab)

  9. Ferrocene conjugated DNA for biosensing and antisense applications

    … assessed. DNA target detection was possible with square wave voltammetry due to the unusual reliance of this technique on the ‘critical frequency’ of the redox active molecule. 2. DNA probes containing thymine-modified FcNA reporter groups were investigated further due the ability of mercuric ions …

    birmingham Download PDF for Ferrocene conjugated DNA for biosensing and antisense applications (opens in a new tab)

  10. Theoretical Modeling of Cortisol Sensor

    … to convert cortisone to cortisol and the Square Wave Voltammetry (SWV) as a preferred method to measure the forward and reverse current of the system. The parameters and equations necessary to estimate the Square Wave Voltammetry (SWV) theoretical response are determined and outlined. The …

    usf Repository record for Theoretical Modeling of Cortisol Sensor (opens in a new tab)

  11. New Electron-Deficient Polycyclic Aromatic Dicarboximides by Palladium-Catalyzed C–C Coupling and Core Halogenation–Cyanation

    … and fluorescence spectroscopy and cyclic or square wave voltammetry. Insights into the molecular structures in the solid state were obtained by single-crystal X-ray analysis. In subsequent studies, highly electron-deficient perylene bisimides and their reduced species have been investigated …

    wurz-thes Repository record for New Electron-Deficient Polycyclic Aromatic Dicarboximides by Palladium-Catalyzed C–C Coupling and Core Halogenation–Cyanation (opens in a new tab)

  12. Mangano ir chromo nustatymo inversiniais elektroanaliziniais metodais tyrimai /

    … of manganese in drinking water by inverse voltammetry using a mercury film electrode. The determination of manganese in drinking water does not need chemical treatment of a sample. Optimal detection conditions: accumulation potential of -1.75 V, accumulation time 5-30 s, anodic dissolution …

    vilnius Repository record for Mangano ir chromo nustatymo inversiniais elektroanaliziniais metodais tyrimai / (opens in a new tab)

  13. Determination of manganese and chromium by electroanalytical stripping methods research /

    … of manganese in drinking water by inverse voltammetry using a mercury film electrode. The determination of manganese in drinking water does not need chemical treatment of a sample. Optimal detection conditions: accumulation potential of -1.75 V, accumulation time 5-30 s, anodic dissolution …

    vilnius Repository record for Determination of manganese and chromium by electroanalytical stripping methods research / (opens in a new tab)

  14. Electrochemical properties of nanoporous based materials doped with metal oxide nanoparticles for potential application as sensors

    … modified electrodes was explored using cyclic voltammetry (CV) and electrochemical impedance spectroscopic techniques (EIS) with ferricyanide/ferrocyanide ([Fe(CN)6]³⁻/⁴⁻) as the redox probe. The mechanism of electron transport between the MO nanomaterial, their nanocomposites`and the …

    nwu-za Repository record for Electrochemical properties of nanoporous based materials doped with metal oxide nanoparticles for potential application as sensors (opens in a new tab)

  15. Design and Fabrication of Microfluidic Electrochemical Sensor for Lead Detection in Drinking Water

    … enhancing analyte-electrode interaction. Square wave voltammetry demonstrated superior lead detection in curved-channel sensors over straight channels, confirmed by calibration curves using deionized and real water samples. For lead detection, the curved-channel sensor achieved a detection …

    york Repository record for Design and Fabrication of Microfluidic Electrochemical Sensor for Lead Detection in Drinking Water (opens in a new tab)

  16. Detection and Melting of Surface-Bound DNA using a Purely Electrochemical Approach

    … chronoamperometry pulses to melt the duplex and square wave voltammetry to monitor the extent of melting. We utilize a scanning potential and constant potential technique to generate melting curves and access the stability and kinetics of the DNA duplexes. Our method uses a mixed monolayer of …

    usfca Repository record for Detection and Melting of Surface-Bound DNA using a Purely Electrochemical Approach (opens in a new tab)

  17. ELECTROCHEMICAL DETECTION AND CATALYTIC OXIDATION OF AROMATIC POLLUTANTS IN WASTEWATER

    … also developed electrochemical sensors based on square wave voltammetry and amperometry for phenol and aniline detection in real time. Such information is important for process optimization and minimization of chemical usage. With a pre-concentration step with an 0.8-V applied voltage on a …

    nus Repository record for ELECTROCHEMICAL DETECTION AND CATALYTIC OXIDATION OF AROMATIC POLLUTANTS IN WASTEWATER (opens in a new tab) Download file for ELECTROCHEMICAL DETECTION AND CATALYTIC OXIDATION OF AROMATIC POLLUTANTS IN WASTEWATER (opens in a new tab)

  18. Nanomaterial-based Electrochemical Immunosensors for the Detection of Cardiovascular Biomarkers

    … electrochemical techniques, such as cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS), were employed to evaluate the electrochemical detection of the CRP antigen. This ultrasensitive method for CRP antigen detection exhibited a very good …

    guelph Repository record for Nanomaterial-based Electrochemical Immunosensors for the Detection of Cardiovascular Biomarkers (opens in a new tab)

Page 1 of 5