  1. Experimental Study of the Heat Transfer on a Squealer Tip Transonic Turbine Blade with Purge Flow

    … structure and heat transfer distribution of a squealer tip rotor blade with purge flow cooling and provide a comparison with a basic flat tip rotor blade without purge flow cooling, under transonic conditions and high inlet free stream turbulence intensity. The blade design was provided by …

    vt Repository record for Experimental Study of the Heat Transfer on a Squealer Tip Transonic Turbine Blade with Purge Flow (opens in a new tab)

  2. Aero-thermal performance and enhanced internal cooling of unshrouded turbine blade tips

    … investigation is undertaken with the use of a squealer or cavity tip design, known for o↵ering the best overall compromise between the tip aerodynamics, heat transfer and mechanical stress. Since there is a lack of understanding of these tips at engine-realistic conditions, the present study …

    oxford Repository record for Aero-thermal performance and enhanced internal cooling of unshrouded turbine blade tips (opens in a new tab)

  3. Turbine blade tip cooling and heat transfer

    … flow can be reduced by using a recessed or squealer tip blade or by cooling the blade tip to incorporate film cooling. The performance of different recessed tip geometries were investigated and compared with plane tip performance. A transient liquid crystal technique was employed to measure …

    lsu-thes Repository record for Turbine blade tip cooling and heat transfer (opens in a new tab)

  4. Turbine Tip Clearance Control Using Fluidic Oscillators

    … on a flat tip, circle jets on a flat tip, squealer tip, 4 fluidic oscillators on a squealer tip, and circle jets on a squealer tip. This study was performed using the commercial CFD package STAR-CCM+. A polyhedral mesh was used for enhanced accuracy and reduced compute times. The …

    ku Repository record for Turbine Tip Clearance Control Using Fluidic Oscillators (opens in a new tab)

  5. Aero-thermal characteristics and film cooling of transonic turbine blade tips

    … performance and a suction side cut-back squealer tip for improved thermal performance at the tip trailing edge. The effects of casing motion were also investigated computationally. The casing motion induces a cavity vortex which increased the local heat transfer coefficient, however there …

    oxford Repository record for Aero-thermal characteristics and film cooling of transonic turbine blade tips (opens in a new tab)

  6. Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement

    … the blade tip region was analyzed for different squealer designs and various cooling conditions. The experimental results reveal that the suction-side squealer tip not only reduces the tip leakage flow from the pressure side but also achieves film cooling effectiveness comparable to that of the …

    tamu Repository record for Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement (opens in a new tab) Embargoed until 2027-08-01

  7. Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement

    … the blade tip region was analyzed for different squealer designs and various cooling conditions. The experimental results reveal that the suction-side squealer tip not only reduces the tip leakage flow from the pressure side but also achieves film cooling effectiveness comparable to that of the …

    tamu Repository record for Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement (opens in a new tab) Embargoed until 2027-08-01

  8. Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement

    … the blade tip region was analyzed for different squealer designs and various cooling conditions. The experimental results reveal that the suction-side squealer tip not only reduces the tip leakage flow from the pressure side but also achieves film cooling effectiveness comparable to that of the …

    tamu Repository record for Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement (opens in a new tab) Embargoed until 2027-08-01

  9. Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement

    … the blade tip region was analyzed for different squealer designs and various cooling conditions. The experimental results reveal that the suction-side squealer tip not only reduces the tip leakage flow from the pressure side but also achieves film cooling effectiveness comparable to that of the …

    tamu Repository record for Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement (opens in a new tab) Embargoed until 2027-08-01

  10. Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement

    … the blade tip region was analyzed for different squealer designs and various cooling conditions. The experimental results reveal that the suction-side squealer tip not only reduces the tip leakage flow from the pressure side but also achieves film cooling effectiveness comparable to that of the …

    tamu Repository record for Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement (opens in a new tab) Embargoed until 2027-08-01

  11. Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement

    … the blade tip region was analyzed for different squealer designs and various cooling conditions. The experimental results reveal that the suction-side squealer tip not only reduces the tip leakage flow from the pressure side but also achieves film cooling effectiveness comparable to that of the …

    tamu Repository record for Experimental Study of Gas Turbine Blade Tip Film Cooling Effectiveness and Internal Heat Transfer Enhancement (opens in a new tab) Embargoed until 2027-08-01

  12. Experimental study of gas turbine blade film cooling and internal turbulated heat transfer at large Reynolds numbers

    … tip on the near tip pressure side and on the squealer cavity floor is investigated. Optimal arrangement of film cooling holes, effect of a full squealer and a cutback squealer, varying blowing ratios and squealer cavity depth are also examined on film cooling effectiveness. The film-cooling …

    tamu Repository record for Experimental study of gas turbine blade film cooling and internal turbulated heat transfer at large Reynolds numbers (opens in a new tab)

  13. Turbine design combining shaping and flow injection by using multiscale methodology

    … flow field indicate that the influence of the squealer height towards the aerodynamic efficiency is caused by two competing effects: the blockage effect to reduce the tip leakage mass flow rate and the sudden expansion loss effect to generate additional losses.</p> <p>By identifying the …

    oxford Repository record for Turbine design combining shaping and flow injection by using multiscale methodology (opens in a new tab)

  14. Heat Transfer and Flow Characteristics on the Rotor Tip and Endwall Platform Regions in a Transonic Turbine Cascade

    … additional secondary flow vortices, such as the squealer cavity vortices and endwall auxiliary vortex system, which significantly increase the stage aerodynamic losses. Furthermore, these vortices result in a low film-cooling effectiveness as was observed on a squealer tip cavity with purge flow. …

    vt Repository record for Heat Transfer and Flow Characteristics on the Rotor Tip and Endwall Platform Regions in a Transonic Turbine Cascade (opens in a new tab)

  15. Thermal and aerodynamic investigation of innovative cooling designs of blade tips

    … is often a limiting factor of engine life. For squealer designs, the pressure side rim near the trailing edge is particularly vulnerable due to its high surface area and highly complex local flow patterns, whilst also being a difficult region to cool. This thesis investigated the aerothermal …

    oxford Restricted access

  16. Film cooling effectiveness measurements on rotating and non-rotating turbine components

    … case of the stationary blade tip, plane tip and squealer tip blades were used while the film cooling holes were located (a) along the camber line on the tip or (b) along the span of the pressure side. The average blowing ratio of the cooling gas was controlled to be 0.5, 1.0, and 2.0. Tests were …

    tamu Repository record for Film cooling effectiveness measurements on rotating and non-rotating turbine components (opens in a new tab)

  17. Numerical Investigations of Flow and Film Cooling with Endwall Contouring and Blade Tip Ejection under Rotating Turbine Conditions

    … are designed and studied at TPFL: the plane and squealer tips with tip hole cooling and the plane and squealer tips with pressure-side-edge compound angle hole cooling. Seven perpendicular holes that are evenly distributed along the camber line are used for the tip hole cooling, whilst eight …

    tamu Repository record for Numerical Investigations of Flow and Film Cooling with Endwall Contouring and Blade Tip Ejection under Rotating Turbine Conditions (opens in a new tab)

  18. Unshrouded turbine blade tip heat transfer and film cooling

    … combine the known benefits of winglet and double squealer tips. The development of the external geometry was performed primarily through engine-representative CFD simulations at a range of tip gaps from 0.45% to 1.34% blade chord. The squealet tip was found to have a similar aerodynamic …

    oxford Repository record for Unshrouded turbine blade tip heat transfer and film cooling (opens in a new tab)

  19. Investigations of flow and film cooling on turbine blade edge regions

    … configurations, such as plane tip, double side squealer tip, and single suction side squealer tip, have been studied to find which one is the best configuration to reduce the tip leakage flow and the heat load. In addition to the flow and heat transfer on the blade tip, film cooling with various …

    tamu Repository record for Investigations of flow and film cooling on turbine blade edge regions (opens in a new tab)

  20. Experimental Investigations of Flow and Film Cooling with Endwall Contouring and Blade Tip Ejection under Rotating Turbine Conditions

    … effectiveness: plane tip with tip hole cooling, squealer tip with tip hole cooling, plane tip with pressure-side-edge compound angle hole cooling and squealer tip with pressure-side-edge compound angle hole cooling. To avoid rotor imbalance, every pair is installed radially. Film cooling …

    tamu Repository record for Experimental Investigations of Flow and Film Cooling with Endwall Contouring and Blade Tip Ejection under Rotating Turbine Conditions (opens in a new tab)