Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"Squirrel cage induction generator"”

  1. Comparison of control strategies for squirrel-cage induction generator-based wind energy conversion systems

    The squirrel cage induction generator will be a robust and low cost alternative to variable speed wind energy conversion systems. For this type of generator, direct torque control, direct stator-field-oriented control, direct rotor-field-oriented control, stator-flux slip control and rotor-flux …

    brazil-ufrn Repository record for Comparison of control strategies for squirrel-cage induction generator-based wind energy conversion systems (opens in a new tab)

  2. Diagnóstico de fallos en generadores tipo jaula de ardilla de turbinas eólicas mediante la señal de corriente

    … and its application to the maintenance of the squirrel-cage induction generator used in WTs. The research includes from the historical aspects of the use of the current signal, theoretical foundations on how the components associated with faults are manifested in the signal spectrum and the …

    valladolid Repository record for Diagnóstico de fallos en generadores tipo jaula de ardilla de turbinas eólicas mediante la señal de corriente (opens in a new tab)

  3. Advances in wind power generation, transmission, and simulation technology

    … show how a Vienna rectifier could drive either a squirrel-cage induction generator or a permanent-magnet synchronous generator-based wind turbine. Computer simulations and experimental results demonstrate the feasibility of the proposed topology and potential improvements in energy conversion …

    iastate Repository record for Advances in wind power generation, transmission, and simulation technology (opens in a new tab)

  4. Modelagem e análise de impacto harmônico de um gerador de indução do tipo gaiola de esquilo interconectado à rede elétrica e acionado por um regulador eletromagnético de frequência

    … an interconnected wind turbine system based on a Squirrel Cage Induction Generator (SCIG) driven by an Electromagnetic Frequency Regulator (EFR). The steady state of the EFR harmonic model is developed in the stationary frame based on the conventional induction generator modeling, which allows the …

    brazil-ufrn Repository record for Modelagem e análise de impacto harmônico de um gerador de indução do tipo gaiola de esquilo interconectado à rede elétrica e acionado por um regulador eletromagnético de frequência (opens in a new tab)

  5. Análise em regime permanente de parques eólicos com máquinas SCIG e DFIG

    … de indução duplamente alimentado (Doubly-Fed Induction Generator-DFIG) e o de velocidade fixa com gerador de indução de rotor de gaiola de esquilo (Squirrel Cage Induction Generator-SCIG). O caso de estudo está baseado no parque eólico Jepirachi na Colômbia, o qual na atualidade tem …

    brazil-ufrgs Repository record for Análise em regime permanente de parques eólicos com máquinas SCIG e DFIG (opens in a new tab)

  6. IMPEDANCE-BASED FAULT LOCATION METHODS FOR TRANSMISSION LINE CONNECTING WIND FARM PLANTS

    … has been studied. Wind plants equipped with induction generator results in a different fault behavior in transmission networks. In this paper, the validation of existing impedance-based fault location methods are performed on a transmission line connecting wind plant equipped with three …

    clemson Repository record for IMPEDANCE-BASED FAULT LOCATION METHODS FOR TRANSMISSION LINE CONNECTING WIND FARM PLANTS (opens in a new tab)

  7. Stability Domains and Bifurcations in Series Compensated Power Networks Subjected to Asynchronous Wind Generation and Induction Motor Dynamics

    … This thesis investigates the stability domain of Squirrel Cage Induction Generator - Wind Turbines (SCIG-WTs) with series compensation and weak interconnections to the power grid. Detailed time-domain and state-space modeling have revealed new bifurcations and oscillatory modes for a SCIG-WT …

    oklahoma-thes Repository record for Stability Domains and Bifurcations in Series Compensated Power Networks Subjected to Asynchronous Wind Generation and Induction Motor Dynamics (opens in a new tab)

  8. Πολυκριτηριακή βελτιστοποίηση της εκμετάλλευσης του αιολικού δυναμικού για τη σύνδεση αιολικών συστημάτων/παρκών στα δίκτυα υψηλών τάσεων

    … generation system is considered consisting by a squirrel cage induction generator connected to the grid by a fully controlled ac/dc/ac IGBT converter. Alternative solutions are proposed, that are less complicated more accurate and easier to be accomplished, a fact that is proved through a …

    greece Repository record for Πολυκριτηριακή βελτιστοποίηση της εκμετάλλευσης του αιολικού δυναμικού για τη σύνδεση αιολικών συστημάτων/παρκών στα δίκτυα υψηλών τάσεων (opens in a new tab)

  9. The simulation of induction generators for microhydro systems: with application to developing countries

    The driving of an induction machine faster than its synchronous speed, causing it to generate electrical power, is described in most textbooks on electrical machines. The principle of self-excitation, by which an induction generator can be excited from static capacitors is not, however, obvious. …

    unsw Repository record for The simulation of induction generators for microhydro systems: with application to developing countries (opens in a new tab)

  10. Optimal control of wind energy conversion systems with doubly-fed induction generators

    … energy resource. The WECS using a doubly-fed induction generator (DFIG) to convert mechanical power into electrical power has a significant advantage. This WECS requires a smaller power converter in comparison with a squirrel cage induction generator. Efficiency of the DFIG-WECS can be …

    birmingham Repository record for Optimal control of wind energy conversion systems with doubly-fed induction generators (opens in a new tab)

  11. Protection of Renewable Energy Systems

    … models with FRT capability. The studies include squirrel cage induction generator and doubly-fed induction generator (DFIG)-based wind farms, as well as full-scale converter-interfaced REPPs. The exclusive fault behavior of REPPs is scrutinized to identify possible relay maloperations and their …

    waterloo Repository record for Protection of Renewable Energy Systems (opens in a new tab)

  12. Modeling, simulation, and analysis of grid connected dish-stirling solar power plants

    … and its use of a non-conventional asynchronous generator. The research presented in this thesis attempts to fill in the gaps between the well established research on Stirling engines in the world of thermodynamics and the use of DS systems in electric power system applications, a topic which has …

    gatech Repository record for Modeling, simulation, and analysis of grid connected dish-stirling solar power plants (opens in a new tab)

  13. Modeling and Controller Design of a Wind Energy Conversion System Including a Matrix Converter

    … electronic converter, is used to interface the induction generator with the grid and control the wind turbine shaft speed. At a given wind velocity, the mechanical power available from a wind turbine is a function of its shaft speed. Through the matrix converter, the terminal voltage and …

    waterloo Repository record for Modeling and Controller Design of a Wind Energy Conversion System Including a Matrix Converter (opens in a new tab)

  14. Fuzzy logic and neural network based advanced control and estimation techniques in power electronics and ac drives

    … and for performance enhancement control. A squirrel cage induction generator fed power to a double-sided PWM converter system which pumped power to a utility grid or to an autonomous system. The system has three fuzzy controllers. The controller FLC-1 searches the generator speed on-line so …

    utk-theses Repository record for Fuzzy logic and neural network based advanced control and estimation techniques in power electronics and ac drives (opens in a new tab)

  15. Protection of Transmission Lines Connected to IG-Based Wind Farms

    … dissertation will mainly focus on doubly fed induction generator (DFIG)-based WFs and will study their negative impacts on the operation of conventional protection relays, particularly the ones that protect the transmission lines connected to DFIG-based WFs. Considering different negative …

    waterloo Repository record for Protection of Transmission Lines Connected to IG-Based Wind Farms (opens in a new tab)

  16. A Small-Scale Standalone Wind Energy Conversion System Featuring SCIG, CSI and a Novel Storage Integration Scheme

    … and efficiency, permanent magnet synchronous generator seems to be the dominating generator type in gearless wind turbines, employed for off-grid applications. However, wind turbines using geared squirrel-cage induction generator (SCIG) are still widely accepted due to their robustness, …

    waterloo Repository record for A Small-Scale Standalone Wind Energy Conversion System Featuring SCIG, CSI and a Novel Storage Integration Scheme (opens in a new tab)

  17. Modeling and Emulation of Induction Machines for Renewable Energy Systems

    … frequencies in the kHz range. In this thesis, an induction motor emulator based on a power electronic converter is developed to allow detailed testing the converter and controller. A proportional-resonant current controller in the abc-frame and pulse-width modulation are employed. The conventional …

    concordia

  18. A Generalized Inverter Control Method for a Variable Speed Wind Power System Under Unbalanced Operting Conditions

    This thesis presents a generalized control method for complete harmonic elimination and adjustable power factor of a grid side inverter under unbalanced operating conditions used in variable speed wind power systems. The theoretical analysis of the proposed control method is described and verified …

    ohiolink Repository record for A Generalized Inverter Control Method for a Variable Speed Wind Power System Under Unbalanced Operting Conditions (opens in a new tab)

  19. Análise da estabilidade de sistemas de geração eólica com aerogeradores de indução com rotor de gaiola

    Dentre as fontes de energia renováveis utilizadas para geração de energia elétrica a que mais se destaca atualmente e a energia eólica. 0 crescente índice de penetração da geração eólica na matriz energética dos sistemas de potencia impõe a necessidade da revisão de conceitos anteriormente …

    brazil-ufrgs Repository record for Análise da estabilidade de sistemas de geração eólica com aerogeradores de indução com rotor de gaiola (opens in a new tab)

  20. Modelagem dinâmica e controle de um gerador tipo DFIG em redes de distribuição

    Neste momento o Brasil possui uma das mais renováveis matrizes energéticas do mundo, mas o desafio de reduzir os níveis de emissão, permitir o crescimento econômico e atender a aproximadamente um milhão de pessoas sem energia elétrica no pais, requer a pesquisa e o desenvolvimento de novas …

    brazil-ufrgs Repository record for Modelagem dinâmica e controle de um gerador tipo DFIG em redes de distribuição (opens in a new tab)

Page 1 of 2