Development and clinical applications of a whole anterior segment and retinal SS-OCT
… in the visual pathway and the dynamic processes associated with it. Since any reduction or loss of vision means a major impairment of our quality of life, many efforts have been made in the development of instruments that can objectively evaluate, diagnose and treat visual conditions and …
-
Intégration et étude d'un système endomicroscopique basé sur MOEMS pour la détection précoce des cancers gastro-intestinaux par SS-OCT
… sont invasives, lentes, coûteuses ou ne fournissent pas une résolution et une profondeur de pénétration suffisantes pour une détection précoce. Une technique d'imagerie prometteuse pour la détection des cancers gastro-intestinaux aux premiers stades est la tomographie par cohérence optique …
-
Characterization of Two Vernier-Tuned Distributed Bragg Reflector (VT-DBR) Lasers Used in Swept Source Optical Coherence Tomography (SS-OCT)
… and acquisition time improvements in SS-OCT applications. To be well suited for SS-OCT, tunable lasers must be capable of producing a highly linear wavelength sweep across a tuning range well-matched to the medium being imaged; many different tunable lasers used in SS-OCT are compared …
-
Multimodal photoacoustic remote sensing (PARS) microscopy combined with swept-source optical coherence tomography (SS-OCT) for in-vivo, non-contact, functional and structural ophthalmic imaging applications
… and optical coherence tomography (OCT). The development of these imaging instruments has greatly extended our ability to evaluate the ocular environment. Studies have shown that at least 40% of blinding disorders in the United States are either preventable or treatable with timely …
-
Spatially multiplexed swept source optical coherence tomography
… technique in optical coherence tomography (OCT) using a broadband frequency-tunable laser is presented for high-speed, high-resolution, depth-resolved imaging of tissue microstructure. Spectral domain techniques in OCT have become the focus of investigation in recent times due to its high …
-
Tomografia de coherència òptica swept-source com a mètode de valoració de la coroide en les coroiditis estromals primàries
… de coherència òptica tipus swept source (SS-OCT), l’aparell es capaç de valorar automàticament el gruix coroïdal; la qual cosa pot permetre tenir una mesura objectiva de l’esmentat gruix i poder valorar l’evolució de les coroïditis estromals primàries (CEP) de forma més fiable, ràpida i no …
-
Point-Spread Function Assessment of SG-DBR Based Swept Source for OCT Imaging
Swept Source Optical Coherence Tomography (SS-OCT) is a medical imaging technique that requires high repetition rate, widely-tunable coherent laser sources. Sampled grating distributed Bragg reflector (SG-DBR) lasers are proven in telecom applications and are expected to fulfill the requirements …
-
Inter-device reliability of swept source and spectral domain optical coherence tomography and retinal layer differences in schizophrenia
INTRODUCTION: Optical coherence tomography (OCT) is used to study retinal structure in schizophrenia. Changes in retinal structure, especially the retinal nerve fiber layer (RNFL) have been correlated with psychotic disorders. Along with a decrease in macular outer nuclear layer (ONL) thickness and …
-
Highly Efficient Spectral Calibration Methods for Swept-Source Optical Coherence Tomography
… techniques in optical coherence tomography (OCT) make use of specialized light sources that sweep across a broad optical bandwidth, allowing for longer depth ranges at higher resolutions. The produced light source signal can be described as a gaussian damped sinusoid that non-uniformly sweeps …
-
Diseño y validación de un índice de actividad objetivo para uveítis basado en la tomografía de coherencia óptica Swept-Source
… tomografía de coherencia óptica swept source (SS-OCT) permiten la adquisición de exploraciones de alta definición del segmento anterior y posterior del ojo. HIPÓTESIS: Presumimos, a priori, que se puede desarrollar una puntuación objetiva de actividad inflamatoria intraocular compuesta, a …
-
Application of polarization sensitive optical coherence tomography (PS-OCT) and phase sensitive optical coherence tomography (PhS-OCT) for retinal diagnostics
… Swept Source Optical Coherence Tomography (EPS-SS-OCT) instrument for high sensitivity cross-sectional imaging of Retinal Nerve Fiber Layer (RNFL) has been designed, constructed, and verified. The instrument is capable of measuring the thickness and birefringence of the RNFL. Birefringence …
-
Effects of optical design on speckle in fiber based optical coherence tomography (OCT)
Angle resolved optical coherence tomography (AR-OCT) was developed to observe the back-scattering angle of incident light on tissues to diagnose the functional state. In order to build the setup, a pathlength multiplexing element (PME) is utilized thereby creating sub-bands in the image. The top …
-
Optical coherence tomography methods using 2-D detector arrays
Optical coherence tomography (OCT) is a non-invasive, non-contact optical technique that allows cross-section imaging of biological tissues with high spatial resolution, high sensitivity and high dynamic range. Standard OCT uses a focused beam to illuminate a point on the target and detects the …
-
Development of Multi-modal Optical Coherence Tomography Imaging Systems and Probes
Optical Coherence Tomography (OCT) is a powerful imaging modality widely used in medical diagnostics and biological research for its non-invasive, high-resolution, and depth-resolved properties. Additionally, OCT has demonstrated remarkable versatility in various applications. In this thesis, we …
-
MULTI-CONTRAST OPTICAL COHERENCE TOMOGRAPHY FOR VARIOUS BIOMEDICAL APPLICATIONS
Optical coherence tomography (OCT) is a label-free optical imaging technique that provides noninvasive visualization of biological tissue microstructures with micrometer-scale resolution and millimeter-scale penetration depth. OCT has become a well-established commercial product in ophthalmology …
-
Advances in Axial Motion-like Artefact correction in Optical Coherence Tomography Imaging
… back in the 1990s, Optical Coherence Tomography (OCT) has been an invaluable tool for biomedical imaging, more so in the area of ophthalmology, thanks to its ability to retrieve structural information from within a scattering sample in a non-destructive, non-invasive, and contactless way. …
-
Using Optical Coherence Tomography to Visualise Fingermarks on the Sticky Side of Adhesive Tape
… of the sample. Optical coherence tomography (OCT) offers a non-contact and non-destructive alternative, providing depth-resolved imaging that can visualise features beneath the surface of the sample. This study investigated the use of swept-source OCT (SS-OCT) for the visualisation of latent …
-
Dispersion in optical configurations and sources for Optical Coherence Tomography
… imaging technique employed to visualize tissue structure, ocular vasculature and blood flow. An OCT system is a non-invasive biomedical imaging system that provides bi-dimensional and three-dimensional images of biological tissue with micrometer scale resolution and millimeter scale depth …
-
Time-Stretched Supercontinuum Swept-Sources for High-Speed Optical Coherence Tomography
… its introduction, optical coherence tomography (OCT) has become a widely used imaging technique for non-invasive, three-dimensional visualisation of biological tissues. Although resolution has steadily improved, imaging speed remains a key limitation-particularly for reducing motion artefacts and …
-
Characterization and Modeling of an O-band 1310 nm Sampled-Grating Distributed Bragg Reflector (SG-DBR) Laser for Optical Coherence Tomography (OCT) Applications
… for Source Swept Optical Coherence Tomography (SS-OCT), a Fourier-Domain based approach for OCT, necessitating a tunable wavelength source. Three internal sections control the frequency output for tuning, along with two amplifiers for amplitude control. These O-band SG-DBR devices are now being …