Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 41 for “"St Jude Medical"”
-
St. Jude Medical: ST Monitoring
… is the leading cause of death in the western world. Time is critical when treating patients with myocardial infarction. The major problem is that many patients who are symptomatic wait too long before seeking medical attention, and some patients have no symptoms at all. In order to …
-
St. Jude Medical: Bi-ventricular Autocapture
Bi-Ventricular Auto Threshold periodically and independently measures and trends the capture threshold of the right and left ventricles in order to determine the minimum pulse amplitude required to capture the heart.
-
St. Jude Medical: Enhanced MICS (eMICS)
Heart disease is one of the most prevalent diseases in the world. The survival chances for patients with ventricular fibrillation/ventricular tachycardia reduces significantly as time passes without treatment and even after getting timely treatment recurring episode are common. These patients can …
-
St. Jude Medical: Pulmonary Edema Monitoring in Pacemakers and ICDS
… pulmonary capillary network into the lung interstitium and alveoli. When the heart is not able to pump blood to the body efficiently, fluid can back up into the veins that take blood through the lungs to the left atrium. This then builds up the pressure in the blood vessels and fluid is pushed …
-
Verification Process of the St. Jude Medical Atrial Fibrillation Implantable Cardiac Monitor Device
The St. Jude Medical SJM ConfirmTM Implantable Cardiac Monitor (ICM) is a small implantable device that is used to detect arrhythmias and stores the electrogram (EGMs) records for physicians to verify the arrhythmia. The objective of this device is to provide physicians with the technology to …
-
STT Event Stream Feature to Assist Software Testing of Impantable Devices in St. Jude Medical
During development and testing of the pacemaker and defibrillator device functionality, engineers in the cardiac rhythm management industry use a patient simulator to ensure device functionality properly before device is tested with an animal or a human. The patient simulator is also used in the …
-
St. Jude Medical: An Object-Oriented Software Architecture for Embedded and Real-Time Medical Devices
Medical devices used for surgical or therapeutic purposes require a high degree of safety and effectiveness. Software is critical component of many such medical devices. The software architecture of a system defines organizational structure and the runtime characteristic of the application used to …
-
A novel design for the housing of bileaflet mechanical heart valves (St. Jude medical model) : a computational approach
The St. Jude Medical (SJM) bileaflet mechanical heart valve (MHV) was approved by the Food and Drug Administration in the late 70’s. The basic idea for the design of the valve is simply two semicircular flat plates pivoting on recessed hinges. The SJM valve provides improved hemodynamics compared …
-
Creating Software Libraries to Improve Medical Device Testing of the Pacing System Analyzer (PSA) at St. Jude Medical
Software testing, specifically in the medical device field, has become increasingly complex over the last decade. Technological enhancements to simulate clinical scenarios and advancements in communicating to medical devices have created the need for better testing strategies and methodologies. …
-
Universal Engineering Programmer – An In-House Development Tool for Developing and Testing Implantable Medical Devices in St. Jude Medical
During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it …
-
"Aortic valve surgery in patients with infective endocarditis: mid-term follow-up of patients treated with the St. Jude medical trifecta(r) valve"
Abstract Background: Despite recent ongoing efforts, there is still no ideal prosthetic valve substitute. It is particularly difficult to choose the appropriate prosthesis to treat infective endocarditis. Objectives: Investigate the outcomes after aortic valve replacement with a stented …
-
Hemodynamic Flow Characterization of St. Jude Medical Bileaflet Mechanical and Bioprosthetic Heart Valve Prostheses in a Left Ventricular Model via Digital Particle Image Velocimetry
… will greatly depend on the flow character downstream the mitral valve thus a better understanding of the flow character is essential. Most in vitro studies of the flow downstream of a MHV have been conducted with the valve in the aortic position. Researchers reported detailed measurements most …
-
Time-Frequency Analysis of Intracardiac Electrogram
The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to …
-
Marketingová strategie pro trh zdravotní techniky
… práce je zaměřena na vývoj marketingové strategie pro zavedení produktů na vysoce konkurečním trhu zdravotnických prostředků. Konkrétně se zaměřuje na zavedení ablačního katetru a mapovacího zařízení pro léčbu srdečních chorob, které vyrábí americká společnost St. Jude Medical. Práce …
-
Physics-Based Li-Svo Cathode Model
A cathode half cell physics-based model for a St. Jude Medical fabricated silver vanadium oxide (SVO) cathode coin cell battery was constructed. The model is based on a single particle Fick's second law approach with the open-circuit potential modeled with a Redlich-Kister equation. By assuming …
-
Degeneración a largo plazo de una prótesis aórtica de pericardio bovino
Debido al aumento en la incidencia de estenosis valvular aórtica en los países desarrollados producto de una población cada vez más envejecida, existe la necesidad de encontrar una bioprótesis valvular aórtica capaz de demostrar un buen desempeño hemodinámico y a la vez una durabilidad a mediano y …
-
Hall Effect Modeling in FEM Simulators and Comparison to Experimental Results in Silicon and Printed Sensors
… developed using secondary data in order to understand their behavior under strong magnetic fields. Given a device geometry and charge carrier density and mobility, the models accurately calculated sensor resistance, Hall voltage under a normally-incident constant magnetic field, and expected …
-
Herzschrittmacher nach transfemoraler Aortenklappenimplantation (TAVI): Analyse des Langzeitstimulationsbedarfs, seiner Auswirkung auf die neurohumorale Aktivität und das Überleben
… bei Patienten mit hochgradiger Aortenklappenstenose und hohem OP-Risiko etabliert. Für diese Intervention stehen derzeit verschiedene Prothesentypen zur Verfügung. Atrioventrikuläre (AV) Blockierungen mit Notwendigkeit der Implantation eines Herzschrittmachers (SM) sind eine typische …
-
CFD study and experimental verification of steady flow in Bi-leaflet heart valve hinge
Since the first bi-leaflet mechanical heart valve (BMHV), St Jude Medical (SJM), was introduced for replacement of diseased natural heart valve in 1977, it has since remained the most popular valve. This is because it has a great advantage of hemodynamic performance than other prosthetic heart …
Page 1 of 3