Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 274 for “"Standoff"”.

  1. Standoff

    … work process during the production of the piece: Standoff. This is not a description of the physical tasks that were undertaken in the production process, nor is it a recipe for extracting the ingredients that form the intricate relationships within the sculpture, but rather it is a collection of …

    vcu Repository record for Standoff (opens in a new tab)

  2. Coherent Raman standoff detection

    … this weak signal is only suitable for standoff detection of chemicals in bulk form. Coherent Raman processes are non-linear phenomenon in which the phase of the scattered light can be predicted or controlled. This can lead to dramatic enhancements in the signal strength through coherent …

    msu Repository record for Coherent Raman standoff detection (opens in a new tab)

  3. Standoff Screws Used In Composite Joists

    … of the 5/16 in. diameter Elco Grade 8 standoff screw as a mechanical shear connector in composite joists. Standoff screws are being investigated as an alternative to welded shear studs in short span composite joists. The data and results obtained from 106 pushout tests performed on the …

    vt Repository record for Standoff Screws Used In Composite Joists (opens in a new tab)

  4. A Standoff Approach to Monitoring Infant Apnea

    … apnea built the foundation for the design of the standoff infant apnea monitor. The monitor is designed to track infant respiration using carbon dioxide and sound signatures of breath without touching the infant. Each detection system, audio and carbon dioxide, were designed separately and brought …

    calpoly Repository record for A Standoff Approach to Monitoring Infant Apnea (opens in a new tab)

  5. Trace Mixture Analysis with Standoff Photothermal Cantilever Deflection Spectroscopy

    Most chemical sensors work by collecting and transporting targeted chemicals for interaction with their sensing elements. When analyte molecules appear in very low concentrations, pre-concentrators are used for enriching the sample. This thesis describes a non-contact method which eliminates the …

    buffalo Repository record for Trace Mixture Analysis with Standoff Photothermal Cantilever Deflection Spectroscopy (opens in a new tab)

  6. The Iranian nuclear standoff those who can help, won't

    In the face of Tehran's vitriolic rhetoric and outright refusal to cooperate with the International Atomic Energy Agency, why do Russia, China and India refuse to support the United States and the EU-3 in their efforts to curtail Iran's pursuit of a complete and indigenous nuclear fuel cycle? …

    nps Repository record for The Iranian nuclear standoff those who can help, won't (opens in a new tab)

  7. Guided standoff weapons a threat to expeditionary air power

    … employed by air base attackers has been the standoff attack. Roughly, 75 percent of all airbase attacks have been through the use of rockets or mortar fire from outside the airbase's perimeter defenses. In Vietnam, where the defenses against penetrating ground attacks were emphasized, this …

    nps Repository record for Guided standoff weapons a threat to expeditionary air power (opens in a new tab)

  8. Evaluation of radar performance degradation due to standoff jamming

    … of Airport Surveillance Radar (ASR-9) due to standoff jamming. ASR-9 data was taken from open literature on this civilian radar. Jammer parameters which are representative of the actual system were postulated to keep the study unclassified. Using these parameters the effect of standoff jamming …

    nps Repository record for Evaluation of radar performance degradation due to standoff jamming (opens in a new tab)

  9. Strength Calculation Model for Standoff Screws in Composite Joists

    … from push-out tests utilizing the ELCO Grade 8 standoff screws. The goal is to develop a strength prediction equation and determine reliability parameters compatible with the Load Factor Resistance Design (LRFD) procedure that would allow the use of this shear connector in design of composite …

    vt Repository record for Strength Calculation Model for Standoff Screws in Composite Joists (opens in a new tab)

  10. Further Investigation of Standoff Screws Used in Composite Joists

    … of the 5/16 in. diameter Elco Grade 8 standoff screw as a mechanical shear connector in composite joists. Standoff screws are being investigated as viable an alternative to welded shear studs in short span composite joists. The data and results obtained from 59 pushout tests performed …

    vt Repository record for Further Investigation of Standoff Screws Used in Composite Joists (opens in a new tab)

  11. Nonlinear acoustical detection of buried landmines using pulsed standoff excitation

    … experiments were performed using a pulsed, standoff source consisting of sixteen speakers mounted on a circular arc. This source, as well as a pair of 18-inch subwoofers, were used separately for acoustical excitation of the buried mine, and the response of the target site was examined as a …

    texas Repository record for Nonlinear acoustical detection of buried landmines using pulsed standoff excitation (opens in a new tab)

  12. Computational Acceleration for Next Generation Chemical Standoff Sensors Using FPGAs

    This research provides the real-time computational resource for three dimensional tomographic chemical threat mapping using mobile hyperspectral sensors from sparse input data. The crucial calculation limiting real-time execution of the algorithm is the determination of the projection matrix using …

    temple Repository record for Computational Acceleration for Next Generation Chemical Standoff Sensors Using FPGAs (opens in a new tab)

  13. Standoff Laser Interferometric Photoacoustic Spectroscopy for the Detection of Explosives

    … explosive materials. Performing detection at a standoff distance is much safer and this is the impetus for this work. Photoacoustic spectroscopy is well suited to the task of explosive detection at a standoff distance. A detailed theory of the standoff measurement of the physical response of a …

    mississippi Repository record for Standoff Laser Interferometric Photoacoustic Spectroscopy for the Detection of Explosives (opens in a new tab)

  14. NAVY EXPLOSIVE ORDNANCE DISPOSAL MARITIME EXPEDITIONARY STANDOFF RESPONSE CASE HISTORY

    … Ordnance Disposal’s (EOD) Maritime Expeditionary Standoff Response (MESR) ROV program of record. Primary objectives of this case history include describing PMS 408 Expeditionary Mission’s middle tier of acquisition (MTA) strategy, the use of rapid prototyping of commercial items to meet the Navy …

    nps Repository record for NAVY EXPLOSIVE ORDNANCE DISPOSAL MARITIME EXPEDITIONARY STANDOFF RESPONSE CASE HISTORY (opens in a new tab)

  15. Standoff screws functioning as mechanical shear connectors in composite joists

    … utilizing the Elco grade 8, 5/16 in. diameter, standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied …

    vt Repository record for Standoff screws functioning as mechanical shear connectors in composite joists (opens in a new tab)

  16. Appalachian standoff : competing information campaigns in the chip mill controversy of the Tennessee Valley

    <p>The media play an important role in how the public perceives issues, especially with controversial issues, by allowing some voices to filter through unscathed, distorting others, and silencing still others.</p> <p>This study analyzes, through interviews, the accuracy and fairness with which the …

    ut-knoxville Repository record for Appalachian standoff : competing information campaigns in the chip mill controversy of the Tennessee Valley (opens in a new tab)

  17. Cost effective analysis comparing the small diameter bomb and the joint standoff weapon (A+ Variant)

    … the cost effectiveness of implementing the Joint Standoff Weapon A+ (JSOW A+) variant versus the Small Diameter Bomb (SDB). The primary goal was to compare the "cost per kill" for each weapon system in its intended operational environment against an existing target set. The secondary goal was to …

    nps Repository record for Cost effective analysis comparing the small diameter bomb and the joint standoff weapon (A+ Variant) (opens in a new tab)

  18. Development of Supercam Calibration Target and scientific capabilities of combined and standoff instruments: Raman and LIBS

    La tesis recopila los diseños de instrumentos Raman remotos realizados por el grupo de investigación y el doctorando, estableciendo las bases teóricas detrás de este tipo de desarrollos. La parte experimental de la tesis se puede dividir en otras dos secciones: una primera sección en la que se …

    valladolid Repository record for Development of Supercam Calibration Target and scientific capabilities of combined and standoff instruments: Raman and LIBS (opens in a new tab)

  19. The Struggle for WHOIS Privacy: Understanding the Standoff Between ICANN and the World's Data Protection Authorities

    This dissertation examines the struggle over privacy rights in WHOIS, the public directory of registrants of Internet domain names. ICANN, the Internet Corporation for Assigned Names and Numbers, is the non-profit corporation established by the U.S. government to run the Domain Name System and the …

    toronto-retro Repository record for The Struggle for WHOIS Privacy: Understanding the Standoff Between ICANN and the World's Data Protection Authorities (opens in a new tab)

  20. Wide Field Measurements Using A Spatial Heterodyne Raman Spectrometer For Transmission Raman Spectroscopy And Standoff Detection

    … the sample and easy coupling to a telescope for standoff Raman. The lack of moving parts and compactness of the SHRS makes the system lightweight and robust, which is ideal for a deployable standoff detection instrument intended for planetary exploration. Our group has demonstrated visible and UV …

    south-carolina Repository record for Wide Field Measurements Using A Spatial Heterodyne Raman Spectrometer For Transmission Raman Spectroscopy And Standoff Detection (opens in a new tab)

Page 1 of 14