Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"Stanton number"”.

  1. Stanton Number for Separated Turbulent Flow Past Relatively Deep Cavities

    Made available in DSpace on 2014-12-09T17:13:26Z (GMT). No. of bitstreams: 1 6403789.pdf: 3006125 bytes, checksum: 787639afc017f305c804113adacf81d3 (MD5) Previous issue date: 1963

    uiuc Repository record for Stanton Number for Separated Turbulent Flow Past Relatively Deep Cavities (opens in a new tab)

  2. Heat transfer, adiabatic effectiveness and injectant distributions downstream of single rows and two staggered rows of film-cooling holes with simple and compound angles

    … adiabatic effectiveness, iso-energetic Stanton number and Stanton number for 0 approximately equal to 1.5 obtained downstream of both one row of holes and two staggered rows of holes. Results indicate that effectiveness depends mostly on four parameters: simple or compound angle …

    nps Repository record for Heat transfer, adiabatic effectiveness and injectant distributions downstream of single rows and two staggered rows of film-cooling holes with simple and compound angles (opens in a new tab)

  3. Heat transfer, adiabatic effectiveness and injectant distribution downstream of single and double rows of film-cooling holes with compound angles.

    … presented include distributions of iso-energetic Stanton number ratios, and adiabatic film-cooling effectiveness deduced from Stanton numbers using superposition. Also presented are plots showing the streamwise development of injectant distributions and streamwise development of mean velocity …

    nps Repository record for Heat transfer, adiabatic effectiveness and injectant distribution downstream of single and double rows of film-cooling holes with compound angles. (opens in a new tab)

  4. Local convective heat transfer in open cavity flow

    … detailed spatial distribution of local (mass) Stanton numbers at the cavity bottom. For rectangular cavities, further insights into the flow structure responsible for the observed distributions is gained through numerical simulations using a k − ω SST model that is first validated using the …

    umn Repository record for Local convective heat transfer in open cavity flow (opens in a new tab)

  5. Direct Numerical Simulations (DNS) of the thermal field in a turbulent channel flow with spanwise sinusoidal blowing/suction

    … and turbulent structures. The Reynolds number of the unperturbed case is Re_\tau=394 (based on the friction velocity and the half-height of the channel) and the molecular Prandtl number is Pr=0.71. Isothermal conditions are assumed for the lower hot and the upper cold walls. The main …

    ttu Repository record for Direct Numerical Simulations (DNS) of the thermal field in a turbulent channel flow with spanwise sinusoidal blowing/suction (opens in a new tab)

  6. Heat transfer modeling of jet vane Thrust Vector Control (TVC) Systems

    … of surface shear stress coefficient, Stanton number and convective heat transfer coefficient.

    nps Repository record for Heat transfer modeling of jet vane Thrust Vector Control (TVC) Systems (opens in a new tab)

  7. Boundary layer transition in hypersonic flows

    … matching the Pohlhausen laminar result for Stanton number in terms of Reynolds number at hypersonic velocities, to turbulent transition by the end of the plate. The tripped heat transfer data seem to indicate the rapid onset of transition and overshoot, followed by a re-laminarization and …

    oxford Restricted access

  8. Characteristics and Hydraulic Behavior of Adsorptive Media for Use in Permeable Reactive Barriers

    … laboratory tests to field conditions. The Froude number can be used to make comparisons between laboratory flume experiments and onsite conditions at a selected cross-section of the Cargill ditch. The Stanton number has been used to evaluate the applicability of scaling between laboratory column …

    usf Repository record for Characteristics and Hydraulic Behavior of Adsorptive Media for Use in Permeable Reactive Barriers (opens in a new tab)

  9. Evolution of Turbine Blade Deposits in an Accelerated Deposition Facility: Roughness and Thermal Analysis

    … coefficients are reported in the form of Stanton numbers to allow for the difference in thermal properties between the conditions and properties of the wind tunnel and its components and those of a real gas turbine. The Stanton numbers for the various surfaces were plotted versus the …

    byu Repository record for Evolution of Turbine Blade Deposits in an Accelerated Deposition Facility: Roughness and Thermal Analysis (opens in a new tab) Download PDF for Evolution of Turbine Blade Deposits in an Accelerated Deposition Facility: Roughness and Thermal Analysis (opens in a new tab)

  10. Heat Transfer Measurements On An Incidence-Tolerant Low Pressure Turbine Blade In A High Speed Linear Cascade At Low To Moderate Reynolds Numbers

    … able to experimentally reproduce low Reynolds numbers at relevant engine Mach number. Having large incidence swing as an additional parameter in the investigation of the boundary layer development, on a low pressure turbine blade, makes this topic unique and as a consequence requires a unique …

    nodak Repository record for Heat Transfer Measurements On An Incidence-Tolerant Low Pressure Turbine Blade In A High Speed Linear Cascade At Low To Moderate Reynolds Numbers (opens in a new tab)

  11. Experimental Heat Transfer Distributions Over An Aft Loaded Vane With A Large Leading Edge At Very High Turbulence Levels

    … were taken at a wide range of Reynolds numbers, ranging from 500,000 to 2,000,000, and seven different turbulence levels. The turbulence levels range from a low turbulence condition of 0.7% to a high turbulence condition of 17.4%. The other turbulence conditions are a small grid far …

    nodak Repository record for Experimental Heat Transfer Distributions Over An Aft Loaded Vane With A Large Leading Edge At Very High Turbulence Levels (opens in a new tab)

  12. Estimation of the Real Area of Contact in Sliding Systems Using Thermal Measurements

    … effects of the normalized length and the Stanton number have a significant impact on the estimation quality, and can change the acceptable sensor domain, if the loss is high. The effect of placing the sensor in the static body can, for low loss, provide a coarse image of the contact …

    vt Repository record for Estimation of the Real Area of Contact in Sliding Systems Using Thermal Measurements (opens in a new tab)

  13. Numerical methods for unsteady conjugate heat transfer

    … governed by the ratio of thermal capacity to the Stanton number. Results show exponential decay towards steady state, with initial temperature differences dictating drift bounds but not decay rates.

    oxford Repository record for Numerical methods for unsteady conjugate heat transfer (opens in a new tab)

  14. Pressure transients in a ruptured gas pipeline with friction and thermal effects included

    … pipe was accounted for using a constant value Stanton Number approach which again was an acceptable approximation considering the comparatively small effect that heat transfer has on the pressure transients. The equations were converted to ordinary differential equations using the Method of …

    city-london Download PDF for Pressure transients in a ruptured gas pipeline with friction and thermal effects included (opens in a new tab)

  15. Direct Numerical Simulation of Flow and Mass Transfer in Spacer-Filled Channels

    … in these channels. A solute with a Schmidt number of 1 at Reynolds numbers of 300, 500 and 800 (based on the bulk velocity and spacer diameter) was considered. The effect of spacer location was also studied for three different configurations, spacer at the centre of the channel, at …

    queens Repository record for Direct Numerical Simulation of Flow and Mass Transfer in Spacer-Filled Channels (opens in a new tab)

  16. A study of the heat transfer and fluid mechanics of the turbulent separating and reattaching flow past a backward facing step using large eddy simulation

    … turbulent flow past the step, at a Reynolds number of 5,540 (based on the step height and upstream centerline velocity) and a Mach number of 0.006, was simulated to validate the formulation. Periodic boundary conditions in the spanwise direction for all variables were employed. All solid …

    iastate Repository record for A study of the heat transfer and fluid mechanics of the turbulent separating and reattaching flow past a backward facing step using large eddy simulation (opens in a new tab)

  17. Effect of vortex circulation on injectant from a single film-cooling hole and a row of film-cooling holes in a turbulent boundary layer, Part 2: injection beneath the vortex upwash

    … 30 degrees with respect to the test surface. Stanton numbers are measured on a constant heat flux surface with a nondimensional temperature parameter of about 1.5. The situation studied is one where the middle injection hole is beneath the vortex upwash. For all results, vortex centers pass …

    nps Repository record for Effect of vortex circulation on injectant from a single film-cooling hole and a row of film-cooling holes in a turbulent boundary layer, Part 2: injection beneath the vortex upwash (opens in a new tab)

  18. A piezoelectric translational flow agitator for active air cooling of electronics.

    … results are provided. A total Reynolds number was defined to characterize the combined effects of cross flow and agitation. The Stanton number developed from the relationship between the total Reynolds number and heat transfer coefficients enables predicting operating performance. …

    umn Repository record for A piezoelectric translational flow agitator for active air cooling of electronics. (opens in a new tab)

  19. Experimental Acquisition Of An Endwall Heat Distribution In A Linear Turbine Cascade

    … will be conducted at three varying Reynolds numbers based on true chord length and exit conditions ranging from 500,000 to 2000,000. The infrared thermography technique will be applied to the acquisition of the endwall heat transfer data due to the full surface image which can be developed …

    nodak Repository record for Experimental Acquisition Of An Endwall Heat Distribution In A Linear Turbine Cascade (opens in a new tab)

  20. Heat Transfer in Coal Water Slurry Flow

    … used to calculate modified Reynolds and Prandtl numbers. In addition, an empirical equation was also used to estimate slurry viscosity from the viscosity of water and solid content. These dimensionless numbers were then used to correlate the heat transfer data represented as dimensionless Nusselt …

    nodak Repository record for Heat Transfer in Coal Water Slurry Flow (opens in a new tab)

Page 1 of 2