Showing 1 to 20 of 51 for “"Static Contact Angle"”.
-
An experimental study of critical heat flux with surface modification and its analytic prediction model development
… surface parameters such as wettability and static contact angle, parameters that the proposed CHF prediction model incorporates. The surface oxidation coating with AP-Plasma makes the surface features (static contact angle, oxidation layer thickness) become more hydrophilic and reduces the …
-
Enhancing Biosensor Performance with Omniphobic Lubricant-Infused Coatings
… in sensitivity) and lower biofilm formation (96° static contact angle) in comparison to unmodified membranes (26%, 32°). The second application is in DNA biosensing, where a novel OLI coating uses carbon dioxide plasma activation to embed oligonucleotide probes. It demonstrates an optimized …
-
Control of static and dynamic wetting through surface functionality
… on the wettability of a solid surface under static and dynamic conditions. Two chemically different substrates were used as model surfaces: (a) a partially methylated titania surface and (b) a mixed self-assembled monolayer of CF3- and COOH-terminated thiols deposited on gold. The surface …
-
Dynamic Contact Angles And Wetting Front Instability In Soils
Dynamic contact could provide a mechanism for initiating the instability of wetting fronts and the formation of gravity fingers/columns in porous media. To study those dynamic contact angles when gravity effects are present, rectangular capillary tubes are used to facilitate the observation of the …
-
Methacrylate homo and copolymers with controlled architecture as adhesive viscosity modifiers in UV curable ink-jet inks
… printing media was undertaken using static contact angle analysis. Dynamic contact angle and adhesion testing was performed on typical printing media of high and low surface energy (dynes cm-1). The addition of the PMMA, PnBMA and PMMA-co-PnBMA copolymer enabled control over viscosity …
-
Liquid water dynamics in a model polymer electrolyte fuel cell flow channel
… is in the implementation of the three phase contact line. Current models use a constant static contact angle, which does not take into account real dynamics. This results in non-physical phenomena such as spherical and suspended droplets, instead of the experimentally observed attached …
-
NUMERICAL SIMULATION OF CONTACT LINE PROBLEMS USING PHASE FIELD MODEL
… to simulate the vapor-liquid system in a rectangle or a cube using the phase field model. When no gravity is considered and the walls are hydrophobic with no-slip boundary condition imposed on all walls, the initial random noise vapor- liquid system will evolve to a stable droplet at the …
-
Lazerinis tekstūravimas plieno vilgumo savybėms keisti /
… texturing. Wettability was determined from static contact angle measurements performed with a contact angle meter. Surfaces with a contact angle of 150° or more were considered superhydrophobic. Laser texturing of stainless steel resulted in a wide range of contact angles (40º – 158º). It …
-
Accident Tolerant Fuels Claddings and the Evolution of their Surface Characteristics under Critical Heat Flux
… chemistry, topography, and wettability. The static contact angle changed from 75º for as-received Zircaloy-4 substrates to almost 20º after the Cr coating deposition. However, a hydrophobic recovery was noticed with environmental surface aging, which was explained by correlating the surface …
-
The Effect of Viscosity on The Puddle Dynamics in Low Gravity Environment
… bounce experiments except that (1) the initial static equilibrium configuration satisfies the static contact angle condition, (2) the initial height of the puddle is limited to the capillary height, and (3), for drop tower test durations on the order of seconds, puddle volumes can be over 104 …
-
Διερεύνηση των μηχανισμών γήρανσης συνθετικών μονωτήρων υπαιθρίου χώρου
… transfer property was evaluated by conducting static contact angle measurements on contaminated specimens of the insulators. The development of surface partial discharges and dry-band discharges was investigated through leakage current measurements and thermal imaging in order to evaluate the …
-
The effect of wetting transparency on the interfacial phenomena between water and solid surfaces: An atomistic modeling investigation
… of solid surfaces, usually characterized by the static contact angle, has been used to correlate the hydrodynamic boundary condition and the thermal transport at solid-liquid interfaces. Recent investigations suggest the existence of quasiuniversal laws correlating the hydrodynamic slip length …
-
Διεπιφανειακά φαινόμενα αλληλεπιδράσης ηλεκτρικών πεδίων και υγρών σε υπερυδρόφοβες επιφάνειες
… surfaces exhibit very high droplet contact angles (typically >150°) and low contact angle hysteresis and are further associated with reduced physical adsorption of proteins, enzymes and other macro-molecules. The superhygrophobic surfaces that were developed met the demand of the …
-
Characterization of structured packing via computational fluid dynamics
… packing parameters (e.g. channel corrugation angle and channel side length). It was found that current industrial packings have channel geometries maximizing pressure drop, indicating some degree of optimization around channel geometry is possible depending on separation needs. Multiphase …
-
PERMEABILITY, STRUCTURAL CHANGES, FLOW REGIME TRANSITIONS IN FUEL CELL CATALYST LAYERS AND A MODEL FOR PREDICTING TRAPPED SATURATION FOR TWO-PHASE FLOW IN POROUS MEDIA
… effects on the structure of CL and flow regime. Static contact angle measurements at a range of RH also indicate possible morphological changes in the CL. In addition, fractional flow theory (FFT) model is adapted to study immiscible displacement of two-phase flow in a porous medium. The …
-
Dopad kapky na porézní oxid železa: VOF simulace
… of this phenomenon. All solid surfaces have a static contact angle of 20°, which is consistent with the hydrophilicity of iron oxide. The porous oxide layer is represented by a pore-resolved computational mesh instead of a volume-averaged continuum model. The grid is reconstructed from the …
-
Surface Templating Using a Photolabile Terpolymer to Construct Mixed Films of Oligomers and Oligonucleotides for DNA Biosensor Development
… with XPS, ToF-SIMS, ellipsometry and static contact angle. Neutral polyethylene glycol (PEG), negatively charged methacrylic acid (MAA) oligomer and dC20 oligonucleotides were used as non-probe oligomers. The probe density on the surface was estimated to be 2.2 ± 0.3 x 10^12 …
-
Characterization of Superhydrophobic Surfaces Fabricated Using AC-Electrospinning and Random Particle Deposition
Surfaces with static contact angle greater than 150 degrees are typically classified as superhydrophobic. Such coatings have been inspired by the lotus leaf. As water flows over a superhydrophobic surface, "slip effect" is produced resulting in a reduction in the skin-friction drag exerted on the …
-
Droplet Impingement Cooling Experiments on Nano-structured Surfaces
… resulting in lower heat transfer. Lower static contact angle on the nano-structured surface has been observed, which implies that changes in surface properties result in enhanced film dynamics and better heat transfer behavior. The results and conclusions of this study should be useful …
-
Surfactants, Thermal And Surface Energy Effects On Emulsions’ Transport Properties: A Study Using Lattice Boltzmann Method
… study the combined effects of temperature, and contact angle on the movement of slugs and droplets of oil in water (O/W) system flowing between two parallel plates and in 3D confined flow study. This is found in the enhanced oil recovery technique which includes thermal, contact angle and …
Page 1 of 3