Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 462 for “"Static pressure"”.
-
Hydrofoil static pressure acquisition at high Reynolds number
… Channel (LCC), the world's largest variable pressure recirculating water tunnel. Several standard flow measurements were made over the course of this project, including surface static pressure field measurements. Static pressure was measured through the use of surface static pressure taps …
-
Static Pressure Recovery Effects of Conical Diffusers with Swirling Inlet Flow
Conical diffusers are used in hundreds of engineering applications in various industries. Some of the operating conditions that they operate under cause swirling flow to enter the diffuser. It is generally well documented that the addition of swirl to the flow of a diffuser allows for greater …
-
Arching Effect for Underground Rectangular Structures Subjected to High Static Pressure
Made available in DSpace on 2014-12-08T23:57:10Z (GMT). No. of bitstreams: 1 6901425.pdf: 4608739 bytes, checksum: 9ae3b9b2ad522c0384033b9a73f96e96 (MD5) Previous issue date: 1968
-
Static Pressure Loss in 12”, 14”, and 16” Non-metallic Flexible Duct
… to determine the effects of compression on pressure drops in non-metallic flexible duct. Duct sizes of 12”, 14” and 16” diameters were tested at a five different compression ratios (maximum stretch, 4%, 15%, 30% and 45%) following the draw through methodology in ASHRAE Standard 120 -1999 – …
-
The Fluctuating Static Pressure Field in a Round Jet Turbulent Mixing Region
Made available in DSpace on 2014-12-11T17:26:11Z (GMT). No. of bitstreams: 1 7500400.pdf: 5346020 bytes, checksum: 2d9871cde9b0081e0867b51eaceb10d6 (MD5) Previous issue date: 1974
-
The Effect of Static Pressure on the Inertial Cavitation Threshold and Collapse Strength
The amplitude of the acoustic pressure required to nucleate a gas and/or vapor bubble in a fluid, and to have that bubble undergo an inertial collapse, is termed the inertial cavitation threshold. The hydrostatic dependence of the inertial cavitation threshold was measured up to 30 MPa in ultrapure …
-
Experimental validation of the "target hood static pressure" balancing method for exhaust ventilation systems
… after installation. The "target hood static pressure" method aims to minimize the time, effort, frustration and confusion invested in the balancing effort. It requires only one and one-half adjustment rounds, can be prepared as a computerized spreadsheet, and substitutes hood static …
-
Static pressure measurements of the shock-boundary layer interaction in a simulated fan passage
… on shock-boundary layer interaction. A back pressure valve was designed for a transonic cascade blowdown wind tunnel, the test section was instrumented, and time-averaged static pressure distributions across the shock boundary layer interaction were obtained. A numerical Navier-Stokes …
-
A study on static pressure reset and instability in variable air volume HVAC systems
… testing five different versions of supply duct static pressure reset strategies that fall into two general categories: Proportional plus Integral control loops, and Trim and Respond control strategies. The testing took place from July 2009 through January 2011 at the Energy Resource Station in …
-
Prediction of the static pressure induced by a foam earplug inside a cylindrical earcanal
… project and focused on the prediction of the static mechanical pressure (SMP) on human’s earcanal wall induced by foam earplug, which is one of the sources of discomfort mentioned in the literatures. Currently, there is no available test bench or methods to measure the SMP at the interface …
-
Base pressure and static pressure for a cone-cylinder at a nominal mach number of 5.8
… Wind Tunnel Leg No. 1 to determine the base pressure on a cone-cylinder at a nominal Mach number of 5.8 in both one-phase and two-phase flow. The scope of the investigation was a determination of interference data necessary for proper evaluation of base pressure results, investigation of the …
-
An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps
… currently faced by test facilities measuring static pressure for air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct of a certain length, based on the unit outlet geometry, and this ducting added to the unit height …
-
AN IMPROVED METHOD FOR WIND-TUNNEL WALL CORRECTIONS DEDUCED BY ITERATING FROM MEASURED WALL STATIC PRESSURE
… p ͚ - pᵢ. Here, i represents any of the 46 static taps distributed over the test section walls. It was decided to use 140 singularity elements for the outer flow description; therefore, a method was devised for fitting a least-squares surface to the measured p̂ᵢ's and integrating to obtain …
Page 1 of 24