Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Statistical image reconstruction"”.
-
Statistical image reconstruction for quantitative computed tomography
Statistical iterative reconstruction (SIR) algorithms for x-ray computed tomography (CT) have the potential to reconstruct images with less noise and systematic error than the conventional filtered backprojection (FBP) algorithm. More accurate reconstruction algorithms are important for reducing …
-
Simultaneous correction for scatter and attentuation in positron emission tomography using statistical image reconstruction methods
… for PET is developed within the context of statistical image reconstruction methods. The principles are demonstrated using both numerical simulations of artificially constructed scatter distributions and Monte Carlo studies of phantoms, showing the viability of this method in practice. In …
-
Development and Implementation of Fully 3D Statistical Image Reconstruction Algorithms for Helical CT and Half-Ring PET Insert System
… imaging modalities for screening, diagnosis, and image-guided treatment planning. Along with the increased clinical use are increased demands for high image quality with reduced ionizing radiation dose to the patient. Despite their significantly high computational cost, statistical iterative …
-
Computational Imaging with Limited Photon Budget
The capability of retrieving the image/signal of interest from extremely low photon flux is attractive in scientific, industrial, and medical imaging applications. Conventional imaging modalities and reconstruction algorithms rely on hundreds to thousands of photons per pixel (or per measurement) …
-
Multi-dimensional extension of the alternating minimization algorithm in x-ray computed tomography
… The state-of-the-art methods to reconstruct CT images have hadgreat development but also face challenges. This dissertation derives novel algorithms toreduce bias and metal artifacts in a wide variety of imaging modalities and increase performancein low-dose scenarios.The most widely available …
-
Multi-dimensional extension of the alternating minimization algorithm in x-ray computed tomography
… The state-of-the-art methods to reconstruct CT images have hadgreat development but also face challenges. This dissertation derives novel algorithms toreduce bias and metal artifacts in a wide variety of imaging modalities and increase performancein low-dose scenarios.The most widely available …
-
Task-based Imaging Performance in 3D X-Ray Tomography: Noise, Detectability, and Implications for System Design
… characteristics; and extension to model-based statistical image reconstruction. In each case, the analytical framework demonstrates the importance of task-based assessment and the capability for system optimization in a fairly broad scope of clinical applications ranging from breast to …
-
Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy
… (kV CBCT) has important applications in image guided radiation therapy (IGRT). In its current state, CBCT is suboptimal for these applications due to its considerable radiation dose, poor soft-tissue contrast and inaccurate Hounsfield Units as a result of in-patient scatter. The specific …
-
Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography
… using single-energy computed tomography (SECT) images, which in principle may introduce large intrinsic uncertainties into estimation results. One major factor that limits the performance of SECT-based methods is the Hounsfield unit (HU) degeneracy in the presence of tissue composition …
-
Geometry optimization and evaluation of PET inserts for simultaneous PET/MR neuroimaging
… properties. A scalable dual-GPU list-mode image reconstruction algorithm has also been developed, which was used in the evaluation of different brain PET scanners. Based on the results of this work, a single-ended readout DLO detector with an area of between 1.5 to 9.6 cm2, a …
-
Evaluation and Clinical Implementation of a Dual-Energy CT Stopping-Power Ratio Mapping Technique for Proton-Therapy Treatment Planning
… from vendor-reconstructed Hounsfield Unit (HU) images. Unfortunately, this approach fails to disambiguate the dependence of HU on differences in density and composition of the underlying tissue and has been shown to have an overall inherent uncertainty of 2-3.5% or 1-6 mm in the range of the …
-
Imaging Techniques for Proton Range Determination in Proton Therapy
… beam range), SECT uncertainty (beam hardening, reconstruction artifacts, etc.), and patient positioning uncertainty (misalignment, motions, and anatomical changes). Two emerging techniques have been proposed to improve proton SRP estimation accuracy in proton therapy: dual-energy computed …
-
Motion Correction and Pharmacokinetic Analysis in Dynamic Positron Emission Tomography
… (also called parametric imaging) of dynamic PET images. Both are required to enable fully quantitative PET imaging which is increasingly finding applications in the clinic. Motion-compensation in Dynamic Brain PET Imaging: Dynamic PET images are degraded by inter-frame and intra-frame motion …