Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"Statistical iterative"”
-
Transitioning Statistical Iterative Dual-Energy CT Reconstruction to the Clinic: Artifact Reduction and Machine Learning-Based Acceleration
… an element-wise basis. On the other hand, DECT statistical iterative reconstruction (SIR) is an alternative DECT imaging technique that simultaneously reconstructs DECT images in both the image and sinogram domains by minimizing a penalized log-likelihood function. DECT SIR has demonstrated …
-
Benefits of adaptive statistical iterative reconstruction and high definition compared with filtered back projection and standard definition multi detector row cardiac imaging with respect to radiation dose and diagnostic accuracy.
… performance and radiation dose between Adaptive Statistical Iterative Reconstruction (ASIR) and High Definition (HD) CT coronary angiography (CTCA) compared with Filtered Back Projection (FBP) and Standard Definition (SD) CTCA using invasive coronary angiography as a reference standard. Methods: …
-
Three-Dimensional Medical Image Registration with Applications in Proton Therapy
… a three-dimensional DIR method into the joint statistical iterative DECT reconstruction algorithm. We successfully demonstrate that inter-scan motion corrections can be integrated into the DECT statistical iterative reconstructions process, enabling accurate imaging of radiological quantities …
-
Tomographic reconstruction with adaptive sparsifying transforms
… from low-dose data. The method combines a statistical iterative reconstruction framework with an adaptive sparsifying transform penalty. An alternating minimization approach is used to jointly reconstruct the image while learning a sparsifying transform adapted to the particular image being …
-
Analytical and Iterative Regularization Methods for Nonlinear Ill-posed Inverse Problems: Applications to Diffuse Optical and Electrical Impedance Tomography
… techniques ranging from analytical to iterative to statistical method, is performed. Based on the comparative results using the aforementioned regularization methods, a novel hybrid method combining the deterministic (mollifier and iterative) and statistical (iterative and statistical) …
-
Non-uniform resolution and partial volume recovery in tomographic image reconstruction methods
… modeled in the reconstruction methods, while, statistical iterative methods can better model these effects, with noise processes, as compared to the analytical methods. Regularization is used to condition the problem and explicit regularization methods are considered better to model various …
-
Development and Implementation of Fully 3D Statistical Image Reconstruction Algorithms for Helical CT and Half-Ring PET Insert System
… their significantly high computational cost, statistical iterative reconstruction algorithms are known to reconstruct high-quality images from noisy tomographic datasets. The overall goal of this work is to design statistical reconstruction software for clinical x-ray CT scanners, and for a …
-
Assessing the Impact of Image Reconstruction and Acquisition Parameters on the Reproducibility of Radiomic Features
… the CT parameters slice thickness, Adaptive Statistical Iterative Reconstruction (ASiR), and contrast timing to quantify their impact on 105 commonly used radiomic features. ComBat’s feature correction was assessed on reproducibility. 143 CRLM patients were prospectively enrolled from …
-
Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy
… reduction of low-dose CBCT was achieved through statistical image reconstruction or image restoration in the CBCT projections. Performance of three statistical iterative image reconstruction algorithms was compared through the noise-resolution-tradeoff analysis. Results of the comparison study …
-
Low Dose Computed Tomography Reconstruction Methods
… of projections. The connection between the statistical iterative CT reconstruction and compressed sensing is explored, based on maximum a posteriori formulation of CT reconstruction. It is shown that this formulation can be transformed into a weighted CS problem, the weights of which are …
-
Multi-GPU Acceleration of Iterative X-ray CT Image Reconstruction
… radiation therapy treatment planning. Statistical iterative reconstruction (SIR) algorithms have the potential to significantly reduce image artifacts by minimizing a cost function that models the physics and statistics of the data acquisition process in X-ray CT. SIR algorithms have …
-
Statistical image reconstruction for quantitative computed tomography
Statistical iterative reconstruction (SIR) algorithms for x-ray computed tomography (CT) have the potential to reconstruct images with less noise and systematic error than the conventional filtered backprojection (FBP) algorithm. More accurate reconstruction algorithms are important for reducing …
-
LWIR Spectral Variability Integration and Improvements to an Earth Observing Statistical Performance Model
… and simulate more realistic LWIR scenarios, a statistical approach to temperature/emissivity separation (TES) called the statistical iterative spectrally smooth temperature- emissivity separation (S-ISSTES) algorithm has been derived and integrated into the FASSP model. The new S-ISSTES module …
-
Advances in dual-energy computed tomography imaging of radiological properties
… projection modelling, which is needed by the statistical iterative reconstruction (SIR) and other advanced DECT reconstruction algorithms. 2) Accurate DECT requires knowledge of x-ray beam properties. Using the Birch-Marshall1 model and beam hardening correction coefficients encoded in a CT …
-
Adaptiv statistisch iterative Rekonstruktion (ASIR) in der cranialen Computertomographie
… in dieser Studie die adaptive statistische iterative Rekonstruktion (ASIR) als Möglichkeit zur Dosisreduktion bei gleichbleibend guter Bildqualität in der nativen cranialen CT untersucht werden. Methodik: 157 Patienten wurden auf 2 unterschiedliche Protokollgruppen mit jeweils 120 kV und …
-
TOMOGRAPHIC IMAGE RECONSTRUCTION: IMPLEMENTATION, OPTIMIZATION AND COMPARISON IN DIGITAL BREAST TOMOSYNTHESIS
… likelihood (ML). We also compared our proposed statistical iterative reconstruction (IR) with particular prior and computational technique to these representative methods. Of all available reconstruction methods in this research, our proposed statistical IR appears particularly promising since …
-
Méthodes statistiques de reconstruction tomographique spectrale pour des systèmes à détection spectrométrique de rayons X
La tomographie à rayons X est une technologie d’imagerie en trois dimensions. Elle se base sur la transmission de rayons X à travers l’objet d’étude. Elle est non destructive mais néanmoins irradiante. Cette technique de visualisation est utilisée principalement dans trois domaines : le diagnostic …
-
Iterative reconstruction as a novel method of radiation dose reduction at computed tomography in patients with Crohn's disease
… The renaissance, rediscovery and refinement of iterative reconstruction removes this limitation allowing either an improvement in image quality without increasing radiation dose or maintenance of image quality at a lower radiation dose compared with traditional image reconstruction. This thesis …
-
Quantification of Inter- and Intra-Tumor Heterogeneity Using Medical Imaging and Its Implication on Response to Radiotherapy in Head and Neck Cancer
… I have adapted the percentage of an adaptive statistical iterative reconstruction (ASiR), slice thickness, tube current and voltage. The signal to noise ratio was measured in 7 predefined regions of interest and the effective dose was estimated using thermoluminescent dosimeters. The optimized …
-
Advanced Techniques for Image Quality Assessment of Modern X-ray Computed Tomography Systems
… control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while maintaining the image quality of the exam at an acceptable level. Therefore, there is a scientific need to establish the dose …