Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"Stator resistance"”.

  1. Parameter identification for vector controlled induction motor drives using artificial neural networks and fuzzy principles

    … identification algorithm for both rotor and stator resistances of a rotor flux oriented induction motor drive, with the best possible convergence results using artificial neural networks and fuzzy logic systems. The thesis focuses mainly on identifying the rotor resistance, which is the most …

    unsw Repository record for Parameter identification for vector controlled induction motor drives using artificial neural networks and fuzzy principles (opens in a new tab)

  2. An improved direct torque controlled interior permanent magnet synchronous machine drive without a speed sensor

    … is built are thoroughly examined. Estimation of stator resistance variation, analysis and compensation of the non-linear effects of the inverter such as forward voltage drop and dead-time, speed sensorless control, and torque and flux ripple minimization for a direct torque controlled IPM motor …

    unsw Repository record for An improved direct torque controlled interior permanent magnet synchronous machine drive without a speed sensor (opens in a new tab)

  3. New Optimal High Efficiency Dsp-based Digital Controller Design For Super High-speed Permanent Magnet Synchronous Motor

    … a straight line with a boost voltage because the stator resistance is negligible and only has a significant effect around the DC frequency. However, for the proposed super high-speed PMSM the situation is quite different because of the motor's size. The stator resistance is quite large compared …

    ucf Repository record for New Optimal High Efficiency Dsp-based Digital Controller Design For Super High-speed Permanent Magnet Synchronous Motor (opens in a new tab)

  4. A sensorless induction machine drive - An implementation study

    … this implementation can handle variations in stator resistance from -37 % up to +60 % with stable low speed operation and variations of at least ±60 % at nominal speed. Stable operation for all speeds is possible even during an increase of rotor resistance by 60 %, but the speed accuracy will …

    chalmers Repository record for A sensorless induction machine drive - An implementation study (opens in a new tab)

  5. Sensorless efficiency optimized induction motor drive with neuro-fuzzy control

    … a sensorless induction motor drive with stator flux oriented direct vector control particularly suited for electric vehicle type applications. The drive starts at zero speed and goes to field-weakening mode for all the four quadrants of operation. A start-up method has been developed that …

    ut-knoxville Repository record for Sensorless efficiency optimized induction motor drive with neuro-fuzzy control (opens in a new tab)

  6. Έλεγχος του σύγχρονου κινητήρα χωρίς αισθητήρες

    … from the measured electrical quantities, such as stator voltages and currents replacing the necessity of any position sensor by state observers. PMSM sensorless rotor position detection approaches can be classified into two main strategies: saliency and signal injection and fundamental excitation …

    greece Repository record for Έλεγχος του σύγχρονου κινητήρα χωρίς αισθητήρες (opens in a new tab)

  7. Analysis of a large drag-cup induction motor

    … has been the calculation of the equivalent rotor resistance and reactance. In this work, an attempt is made to derive an equation for calculating the equivalent rotor resistance of a large drag-cup induction motor, to evaluate the effect of rotor reactance in calculation of the performance …

    ut-knoxville Repository record for Analysis of a large drag-cup induction motor (opens in a new tab)

  8. Control Aspects for Energy-Efficient and Sensorless AC Motor Drives

    … system. The observer is augmented with a stator-resistance adaptation scheme in the low-speed region. In high-speed applications with limited sampling frequency, dynamic performance of the discrete-time approximation of a continuous-time controller can dramatically decrease, and can, in …

    aalto Repository record for Control Aspects for Energy-Efficient and Sensorless AC Motor Drives (opens in a new tab)

  9. Rotor resistance estimation ASM

    … this goal is the accurate estimation of rotor resistance, which plays a vital role in narrowing the efficiency gap between IMs and PMSMs. The main goal of this thesis was to compare different rotor resistance estimation techniques within a simulation environment. To achieve this, two distinct …

    chalmers Repository record for Rotor resistance estimation ASM (opens in a new tab)

  10. Advanced Flux-Weakening Control Methods for Interior Permanent Magnet Synchronous Motors with Torque Performance Improvement

    … dynamic performance by establishing a new stator flux linkage adjustment method. The stator flux linkage reference is adjusted based on the torque reference, operating speed, and modulation index. Two voltage feedback paths are established and chosen based on the torque reference and …

    mcmaster Repository record for Advanced Flux-Weakening Control Methods for Interior Permanent Magnet Synchronous Motors with Torque Performance Improvement (opens in a new tab)

  11. Contributions to the Theory and Application of Multiple Model Estimation

    … is applied to the identification of the stator resistance of a permanent magnet motor, and the results are compared to those produced by the extended Kalman filter. This application demonstrates the advantage of preserving the linearity of a system in the parameter identification problem. …

    marquette Repository record for Contributions to the Theory and Application of Multiple Model Estimation (opens in a new tab)

  12. Sensorless direct torque and flux control of interior permanent magnet synchronous motors at very low speeds including standstill

    … with a constant switching frequency. Several stator flux and speed estimators are proposed to achieve sensorless control. The simple open-loop estimator works well only in the medium to high speed region. This is because the other problems of the DTC such as non-linearities of the inverter, …

    unsw Repository record for Sensorless direct torque and flux control of interior permanent magnet synchronous motors at very low speeds including standstill (opens in a new tab)

  13. Energy Usage Evaluation and Condition Monitoring for Electric Machines using Wireless Sensor Networks

    … incorporating sensorless rotor-speed detection, stator-resistance estimation, and loss estimation techniques. Following this approach, two new methods are proposed for estimating the efficiencies of in-service induction motors, using air-gap torque estimation and a modified induction motor …

    gatech Repository record for Energy Usage Evaluation and Condition Monitoring for Electric Machines using Wireless Sensor Networks (opens in a new tab)

  14. Permanent Magnet Condition Monitoring in Permanent Magnet Synchronous Machines

    … for simultaneous estimation of PM flux and stator resistance, (2) a d-axis flux observer with harmonic analysis to distinguish between uniform and asymmetric PMD, and (3) a disturbance observer enhanced with speed offset for robustness against inverter nonlinearity and parameter mismatch. …

    concordia Download PDF for Permanent Magnet Condition Monitoring in Permanent Magnet Synchronous Machines (opens in a new tab)

  15. Direct torque controlled induction machines for integrated starter/alternator system

    … An improved DTC of the ISA based on direct stator flux vector is presented to reduce the drawbacks of high torque and flux ripples of the classical DTC. Robust design of the controller ensures the system is not sensitive to the variation of rotor resistance. By controlling the …

    unsw Repository record for Direct torque controlled induction machines for integrated starter/alternator system (opens in a new tab)

  16. High-Accuracy Torque Control and Estimation for Interior Permanent Magnet Synchronous Machine Drives with Loss Minimization

    … The optimality is proved. The influences of the stator resistance, the equivalent inverter-loss and core-loss resistance in the proposed circuit are researched. Compared to maximum torque per ampere (MTPA) control, LMC introduces more efficient energy utilization. Due to the nonlinearities, the …

    mcmaster Repository record for High-Accuracy Torque Control and Estimation for Interior Permanent Magnet Synchronous Machine Drives with Loss Minimization (opens in a new tab)

  17. A New Deadbeat Direct Torque and Active Flux Control for Interior Permanent Magnet Synchronous Machine Drives

    … DB control where the active flux, instead of the stator flux, is used as a control variable along with the torque. Unlike the conventional DB controls for IPMSM, the proposed method becomes a decoupled control that significantly reduces the complexity of calculating the DB stator voltage vector. …

    unsw Repository record for A New Deadbeat Direct Torque and Active Flux Control for Interior Permanent Magnet Synchronous Machine Drives (opens in a new tab)

  18. Torque and current response due to singularity changes of induction machine slip

    … circuit of the induction motor, with the stator resistance, R_s, and the stator reactive reactance, jX_s, being neglected. It is clone to simplify the complexity of the computations and the computer programming, and it is a real and practical assumption. The Laplace Transformation method …

    njit Repository record for Torque and current response due to singularity changes of induction machine slip (opens in a new tab)

  19. A Non-intrusive Method for Mechanical Measurements in Constant Frequency Electric Motors

    … decoupled from driven load, (3) deenergized stator resistance measurements, i.e. with motor electrically disconnected. These three conditions require a level of access to the motor under test not generally acceptable or possible in an industrial environment, i.e. these are the “intrusive” …

    tamu Repository record for A Non-intrusive Method for Mechanical Measurements in Constant Frequency Electric Motors (opens in a new tab)

  20. Analysis of the dynamics of the linear-and-rotary-motion energy-conversion systems with active DC excitation

    … of DC current directly or indirectly into IM stator windings via different closed-loop motor-control algorithms. In a DTC motor-drive system, the modeling work makes it possible to excite the DC current indirectly inside the motor by superimposing a stator-flux-linkage-bias command in the …

    gatech Repository record for Analysis of the dynamics of the linear-and-rotary-motion energy-conversion systems with active DC excitation (opens in a new tab)

Page 1 of 2