Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"Steady and pulsatile flow"”

  1. Numerical study of steady and pulsatile flow through stenosed tubes

    … solver being capable of dealing with complex flow fields in stenosed tubes and then to apply the developed numerical solver to study the flow phenomena through arterial stenoses. A fully implicit numerical method is developed to solve steady and unsteady incompressible laminar and turbulent …

    nus Repository record for Numerical study of steady and pulsatile flow through stenosed tubes (opens in a new tab)

  2. Numerical simulation of steady and pulsatile flow through smoothly constricted tube

    Numerical simulations have been carried out for steady and pulsatile laminar flow in tubes with single constriction and series constrictions. The second-order finite volume method has been developed to solve the governing equation on a non-staggered non-orthogonal grids. For steady flow, the most …

    nus Repository record for Numerical simulation of steady and pulsatile flow through smoothly constricted tube (opens in a new tab)

  3. Aspects of steady and pulsatile flow in branched tubes with particular reference to blood flow

    <p>The nature of the flow in branching blood vessels is of importance to physiologists, mainly on account of the formation of atheromatic deposits which occur frequently at sites of branching. The reasons for the occurrence of these deposits are not yet understood but it is generally agreed that …

    oxford Repository record for Aspects of steady and pulsatile flow in branched tubes with particular reference to blood flow (opens in a new tab)

  4. Numerical simulations of blood flow in arteries using fluid-structure interactions

    … number one cause of death in the United States and worldwide. Among the various CVDs, coronary artery disease (CAD) is the leading cause of death among both men and women. Of the various forms of CADs, atherosclerosis is the primary cause. To investigate these arterial diseases, numerical …

    wichita-thes Repository record for Numerical simulations of blood flow in arteries using fluid-structure interactions (opens in a new tab)

  5. High-order incompressible Navier-Stokes equations solver for blood flow

    … the incompressible Navier-Stokes (NS) equations and was applied to analyze the blood flow. First, a computer code was written to solve incompressible Navier- Stokes equations using the exact projection method/fractional step scheme. A fifth-order weighted essentially nonoscillatory (WENO) spatial …

    wichita-thes Repository record for High-order incompressible Navier-Stokes equations solver for blood flow (opens in a new tab)

  6. Control of a rotary blood pump

    … option which improves their medical prognosis and quality of life. The broad aim of this thesis is to address the need for a pump control strategy, and develop a solution whereby the implant recipient’s physiological requirements are continuously monitored in a non-invasive manner and met with …

    unsw Repository record for Control of a rotary blood pump (opens in a new tab)

  7. Fluid-structure interaction of steady and pulsating flow through a collapsible thin-walled vessel

    … interactions in collapsible tubes under steady and pulsatile flow conditions, which holds significant implications for many physiological fluid transport phenomena. Quantitative analysis of structural deformation and flow field analysis were conducted utilizing Particle Image Velocimetry …

    ndsu Repository record for Fluid-structure interaction of steady and pulsating flow through a collapsible thin-walled vessel (opens in a new tab)

  8. DEVELOPMENT AND VALIDATION OF A MODULAR PERFUSION PLATFORM FOR PRECONDITIONING OF 3D BIOPRINTED TISSUE CONSTRUCTS

    … these constructs so they can better withstand the physiologic environment after implantation, and maintaining data on these preconditions to increase repeatability. In particular, endothelialized vascular constructs must maintain an intact endothelial monolayer to reduce the risk of …

    wfu Repository record for DEVELOPMENT AND VALIDATION OF A MODULAR PERFUSION PLATFORM FOR PRECONDITIONING OF 3D BIOPRINTED TISSUE CONSTRUCTS (opens in a new tab)

  9. Particle Image Velocimetry in Cerebral Aneurysm Models to Evaluate Fluid Dynamic Performance of Flow Diverting Stents Across Parent Vessel Sizes

    … associated with reduced treatment success rates and require advanced surgical approaches. The current standard of treatment for WNAs is the flow diverter which minimizes aneurysmal inflow and provides an endovascular scaffold for the parent vessel, ultimately inducing aneurysm occlusion. As the …

    gatech Repository record for Particle Image Velocimetry in Cerebral Aneurysm Models to Evaluate Fluid Dynamic Performance of Flow Diverting Stents Across Parent Vessel Sizes (opens in a new tab)

  10. Improving Quantification of Mitral Regurgitation Through Computational Fluid Dynamics and Ex Vivo Testing

    … (PISA) method continues to be the most accurate and clinically used method. However, there are some difficulties obtaining the necessary measurements need for this when performing transthoracic echocardiography. This study aims to evaluate and present techniques that may be used to more …

    denver Repository record for Improving Quantification of Mitral Regurgitation Through Computational Fluid Dynamics and Ex Vivo Testing (opens in a new tab)

  11. Towards Real-time Simulation of Ultrasound Systems

    … used to diagnose multiple diseases. Sonographers and physicians have to devote a substantial amount of time learning how the combination of the various parameters of the ultrasound system affects the resulting ultrasound information among its different modalities. The primary objective of this …

    toronto-retro Repository record for Towards Real-time Simulation of Ultrasound Systems (opens in a new tab)

  12. Application of passive flow control to mitigate the thromboembolic potential of bileaflet mechanical heart valves: an in-vitro study

    … Mechanical heart valves have been the gold standard in valve heart replacement since the 1950s with BMHVs currently still being the valve of choice for younger patients. Given that a large body of literature points to thromboembolic complications due to poor hemodynamics, improvements to the …

    colostate Repository record for Application of passive flow control to mitigate the thromboembolic potential of bileaflet mechanical heart valves: an in-vitro study (opens in a new tab)

  13. Flow and pressure measurement using phase-contrast MRI : experiments in stenotic phantom models.

    … as any pathologic process obstructing the blood flow of the arteries supplying the lower extremities. Moderate stenoses mayor may not be hemodynamically significant, and intravascular pressure measurements have been recommended to evaluate whether these lesions are clinically significant. …

    louisville Repository record for Flow and pressure measurement using phase-contrast MRI : experiments in stenotic phantom models. (opens in a new tab)

  14. Mechanisms of flow-induced responses in piglet isolated cerebral arteries

    We examined the effect of changing both steady and pulsatile flow on piglet cerebral artery diameter. Cerebral arteries were mounted on glass cannulas and bathed in and perfused with heated physiologic saline solution (PSS). An electronic system controlled pressure and a syringe pump provided …

    marquette Repository record for Mechanisms of flow-induced responses in piglet isolated cerebral arteries (opens in a new tab)

  15. Flow Characterization Under Idealized Stenosis Geometry and Performance Assessment of the Hemodynamic Flow Facility

    … to atherosclerosis experience a complex flow environment. Endothelial Cells (ECs) lining the inner wall of arteries are sensors to spatially and temporally varying shear stress (i.e. wall shear stress gradients). This complex force-loading can disrupt local cell-to-cell attachment regions …

    uwo Repository record for Flow Characterization Under Idealized Stenosis Geometry and Performance Assessment of the Hemodynamic Flow Facility (opens in a new tab)

Page 1 of 2