Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 32 for “"Steel, Structural. Testing."”
-
Behaviour of bolted double angle beam connections subjected to eccentric loads
This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca. The full policy for eScholarship may be …
-
A brief study of welded joints of structural steel
Thesis (B.S.)--Michigan State College of Agriculture and Applied Science, 1931
-
Elastic tests on steel beams with eccentric rectangular web openings
Digitized by Kansas Correctional Industries
-
Elastic tests on steel beams with eccentric rectangular web openings
Digitized by Kansas Correctional Industries
-
Some relationships between elastic and plastic methods of structural steel design
no abstract provided by author
-
Precast concrete connections with embedded steel members
This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca. The full policy for eScholarship may be …
-
Strain Rate Effects on a Ductile Moment Resisting Frame with RBS Connection Subjected to Seismic Ground Motions
… at different strain rates for two grades of steel. The strain rate dependent material properties for these materials are used in different combinations on beams and columns of moment resisting frame (MRF) with RBS to conduct non-linear dynamic analyses subjected to earthquake records at …
-
Development of nondestructive techniques for assessment of microstructure in steels
Includes bibliographical references (pages 125-130).
-
A fracture mechanics-based approach for modeling delamination of spray-applied fire-resistive materials from steel structures
Steel structures exhibit lower fire-resistance due to high thermal conductivity of steel and rapid deterioration of strength and stiffness properties of steel with temperature. Therefore, steel structures are to be provided with fire insulation to achieve required fire resistance. This is often …
-
Shear and Compression Strength of Cold-formed Steel Clip Angles Subjected to Different Screw Patterns
… and numerical analysis of the cold-formed steel clip angle in three different limit states which are shear, compression, and combination of the screw connection. A previous cold-formed steel clip angle test program (which is Phase 1) developed design methods for clip angle. Therefore, the …
-
Characterization of fatigue damage in A36 steel specimens using nonlinear Rayleigh surface waves
A36 steel is a commonly used material in civil engineering structures where fatigue damage can lead to catastrophic failure. In this research, nonlinear Rayleigh surface waves are used to characterize damage in A36 steel specimens caused by monotonic tension and low cycle fatigue. Fatigue damage …
Page 1 of 2