Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"Steel joists"”.
-
Web strength of rolled steel joists
… with the behaviour of thin webbed rolled steel joists or universal beams when they are subjected to concentrated loads applied to the flanges. The prime concern is the effect of high direct stresses causing web failure in a small region of the beam. The review shows that although many …
-
Reinforcement Schemes for Cold-Formed Steel Joists Having Web Openings
The use of cold-formed steel (CFS) structures has become increasingly popular in different fields of building technology. For example, small housing systems using cold-formed steel for wall structures, framing systems and roof structures, including trusses and shielding materials, have been …
-
DIAGONAL ERECTION BRIDGING FOR OPEN WEB STEEL JOISTS WITH FLUSH FRAME CONNECTIONS
<p>Open web steel joists are highly slender structural members that are susceptible to lateral-torsional buckling before bracing is installed. The stability of joists needs to be properly assessed to ensure safety and efficiency during erection. Current practice for joists is based on a strength …
-
Evaluation of deck fasteners functioning as shear connectors for composite steel joists
… as shear connectors for composite open web steel joists is studied. Results of thirty-six push-off tests are evaluated in terms of strength and behavior. Six types of deck fasteners are considered. They are: 1. #12-24 Teks/5 self-drilling, self-tapping screws. 2. 1/4-14 Teks/3 with a 1 1/4 …
-
Ultimate strength analysis of partially composite and fully composite open-web steel joists
The behavior of composite steel joists with various degrees of shear connection is investigated. The results of eight full-size composite joist tests, conducted as a portion of the study, are presented. Joist spans range from 24 ft. to 30 ft. and depths from 8 in. to 18 in. Six types of mechanical …
-
Effective Length K-Factors For Flexural Buckling Strengths Of Web Members In Open Web Steel Joists
Open web steel joists are designed in the United States following the governing specification published by the Steel Joist Institute. For compression members in joists, this specification employs an effective length factor, or K-factor, in confirming their adequacy. In most cases, these K-factors …
-
Feasibility Study of Partially Restrained Connections
… throughout the element. Combining this idea with steel joists, which are also quite common in construction, makes for shallower story heights and lower steel weights. This initial study analyzes partially restrained connections for both hot rolled shapes and steel joists using non-composite and …
-
Elastic-plastic finite element modeling of long span composite joists with incomplete interaction
… analyses of seven long span composite open-web steel joists. These analyses account for the incomplete interaction between the concrete slab and the steel joist by modeling the nonlinear behavior of the steel shear connectors. Experimental tests on long span composite open-web steel joists were …
-
Composite Open-Web Trusses with Metal Cellular Floor
<p>Tests on six composite open-web steel joists and concrete slabs with ribbed metal decking are described. The joists spanned 50 ft. and were loaded by two symmetrical point loads. Different types of shear connectors and different degrees of connection were used. Tests results are shown and …
-
Blast resistant design for roof systems
… roof structures and the resistance of open web steel joists. A procedure has been developed to devise a uniform dynamic load on a roof that matches the response from blast loads. This research uses finite element analysis to evaluate the responses from numerically calculated blast loads and …
-
Evaluation of long span composite joists
… characteristics of longspan composite open-web steel joists are studied. Eight full scale single span composite joists were tested to failure to evaluate their performance in both the elastic and inelastic ranges. The test specimens' spans, depths, slab depth, and amount of shear connection was …
-
Evaluation of a proposed vibration criterion
… floor system consisting of a concrete slab on steel joists or beams is susceptible to annoying vibrations caused by walking. This investigation considers a criterion developed by Allen (1991) that indicates whether a proposed structural floor system is acceptable for walking vibrations. The …
-
Two-Way Steel Floor System Using Open-Web Joists
… and architects. Many attempts have been made in steel construction to adopt design philosophies that utilize structural floor members with high span/depth ratios. These designs, however, have been limited to floor systems that predominantly span in one direction. The primary objective of this …
-
Designing Steel Joist Seats Subjected to Rollover Forces
The mechanisms governing the response of steel joist seats subjected to rollover forces were identified through physical testing of fifteen specimen pairs and the applications of concepts from Fisher et al. (2002) and Green and Sputo (2002). The experimental test method was developed based on the …
-
Influence of Construction Details on the Vibration Performance of Cold-Formed Steel Floor Systems
… residential construction practice. Cold-formed steel floor systems are usually lighter and have less inherent damping. If designers are going to use the current span deflection criteria when designing residential floor systems, it is imperative to find the construction and design details that …
-
Experiments on Cold-Formed Steel Beams with Holes
… were performed on 68 C-section cold-formed steel joists with unstiffened rectangular web holes. Four Steel Stud Manufacturers Association (SSMA) cross-section types; 800S200-33, 800S200-43, 1000S162-54, and 1200S162-97, were evaluated to explore the influence of holes on local, distortional, …
-
Numerical and Experimental Investigations on Static Behaviour of Composite Cold-Formed Steel and Timber Flooring System
Currently, the use of Cold-Formed Steel (CFS) joists with timber-based floorboards for constructing lightweight flooring systems in residential buildings is widespread. However, the potential benefits of composite action that arise due to the interaction of the top flange of cold-formed steel joist …
-
Optimization of prefabricated joists
… the performance of precast prestressed concrete joists used for floor or roof members. The main objective of this study was to create a joist with web openings. The benefits of web openings are two-fold. First, a reduction of the double tee weight itself is achieved. Second, the web openings are …
-
Strength of welded headed studs in ribbed metal deck on composite joists
Standards for stud strength in composite joists are presently not available. Existing standards for composite design are targeted for composite beam design while design of a composite joist requires more emphasis on stud strength to fully develop the joist bottom chord. Stud placement in the deck …
-
Investigation of several aspects of the vibration characteristics of steel member-supported floors
… influencing the vibration characteristics of steel member supported floors were investigated. The four aspects are: 1) the number of tee-beams effective in resisting a heel-drop impact for steel joist and steel beam-concrete slab floors, 2) the effective moment of inertia of steel joist and …
Page 1 of 2