Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 54 for “"Steel moment-resisting frames"”
-
Parametric collapse evaluation of steel moment resisting frames with fuse connections
… a low damage seismic design concept for steel moment resisting frames (MRFs): the moment resisting fuse connection. Fuse connections are moment resisting connections that yield prior to the beam or column they connect. The connection acts as an easily repairable structural fuse of the …
-
Seismic design procedure for steel moment resisting frames with viscous dampers
… drifts of elastic or mildly inelastic structures.Steel moment-resisting frames (MRFs) with viscous dampers are prone to plastic mechanisms that involve hinges in columns because of the large column axial forces due to the large damper forces and have less collapse resistance than conventional …
-
Inelastic Analysis of Steel Moment Resisting Frames in Light-Framed Wood Buildings
A preliminary quantitative analysis of steel moment resisting frames as the lateral force-resisting system for light-framed wood buildings was completed to identify issues requiring more advanced study. A two-story prototype building was evaluated. The lateral force-resisting system of the building …
-
Preliminary analysis of doubler plate attachment details for steel moment resisting frames
In steel moment resisting frames, the region of the column located within the beam-column joint is known as the panel zone. When a steel moment resisting frame is subjected to lateral load, due to wind or seismic loads, the panel zone is subject to high shear. In some cases, the shear in the panel …
-
Cyclic loading analysis of doubler plate attachment details for steel moment resisting frames
… zone region in columns of seismic resistant steel moment frames are subject to very high shear forces during earthquake loading. Doubler plates are often used to increase the stiffness and strength of the panel zone. The methods and details used to attach doubler plates to columns can affect …
-
Finite element analysis of welds attaching short doubler plates in steel moment resisting frames
… performance of panel zones in seismic-resistant steel Special Moment Resisting Frames (SMF). These recent studies investigated various options for attaching doubler plates to the column at beam-column joints in SMF for purpose of increasing the shear strength of the panel zone. This previous work …
-
Towards More Optimized and Resilient Seismic Design of Buildings With Steel Moment Resisting Frames
… are the changes made to design provisions for steel moment resisting frames (MRFs) following the 1994 pre-Northridge earthquake, where the pre-qualified connection detailing now prescribed for steel moment resisting frames increases the resistance to collapse but still relies on plastic …
-
Modeling and Behavior of the Beam/Column Joint Region of Steel Moment Resisting Frames
… and yielding on the stiffness and strength of steel moment resisting frames (SMRF) has been the topic of numerous papers over the past thirty years. When properly detailed, the PZ is an excellent source of energy dissipation, even under large inelastic deformations. Due to these large inelastic …
-
Earthquake-induced collapse of steel moment resisting frames with conventional and high performance steel columns
… reduced the earthquake-induced collapse risk in steel frame buildings designed in seismic regions. Experiments suggest that the steel column behaviour may be significantly compromised due to member and local geometric instabilities, thereby increasing the associated collapse risk and likelihood …
-
Clt infill panels in steel moment resisting frames as a hybrid seismic force resisting system
This paper examines CLT-steel hybrid systems at three, six, and nine storey heights to increase seismic force resistance compared to a plain wood system. CLT panels are used as infill in a steel moment frame combining the ductility of a steel moment frame system with a stiffness and light weight of …
-
Development of Dissipative Steel Column-Base Connections for Steel Moment-Resisting Frames under Seismic Loading
In capacity-designed steel moment resisting frames (MRFs), column base connections feature a strong-base/weak-column design philosophy. Prior studies on fixed-end wide flange steel columns featuring seismically compact cross sections subjected to coupled axial load and lateral drift demands suggest …
-
Collapse risk assessment of steel moment resisting frames designed with deep wide-flange columns in seismic regions
… risque de ruine de bâtiments avec des "special moment-resisting frames" (SMFs) définis par ASCE (2010) ou des cadres ductiles de Type D définis par NBCC (2010). Les contributions du plancher composite et du système de résistance aux charges gravitaires sont traitées dans les modèles analytiques. …
-
Collapse risk of tall steel moment-resisting frames in deep sedimentary basins during large magnitude subduction earthquakes
… of earthquake ground motions at long periods. Steel moment-resisting frames are important, because they are one of the most common structural system types in the existing tall building inventory of western US cities, and due to concerns regarding the potential for fracture-prone welded …
-
Improved Seismic Design Recommendations for Wide-Flange Columns in Ductile Steel Moment-Resisting Frames considering Three-dimensional Response
… columns are commonly used in the construction of steel moment-resisting frames (MRFs) to resist lateral seismic loads in high seismic regions in North America. Past studies on deep columns with base plastic hinges located at the first storey of MRFs have indicated that such sections can be prone …
-
Use of Incremental Dynamic Analysis to Assess the Performance of Steel Moment-Resisting Frames with Fluid Viscous Dampers
… Analysis to assess the seismic performance of steel moment-resisting frames with fluid viscous dampers subjected to earthquake ground motions. The study systematically investigated the effects of linear and nonlinear dampers on the response of steel moment-resisting frames to earthquakes that …
-
Risk-Based Life-Cycle Cost-Benefit Analysis of Seismic Retrofitting Steel Moment-Resisting Frames in Canada using Friction Devices
Many existing steel moment-resisting frames (MRFs) in Canada constructed between the 1960s and 1980s were not seismically designed. Friction devices have shown promise to reduce the seismic damage of early-designed steel buildings by supplementing additional force, stiffness, and energy dissipation …
-
Lateral behaviour and direct displacement based design of a novel hybrid structure : cross laminated timber infilled steel moment resisting frames
… been developed as an alternative lateral-load resisting system at The University of British Columbia. The hybrid structure incorporates Cross Laminated Timber (CLT) shear panels as an infill in steel moment resisting frames (SMRFs). In order to increase the applicability of the proposed system, …
Page 1 of 3