Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"Stent coating"”
-
Coating stent materials with polyhedral oligomeric silsesquioxane-poly(carbonateurea)urethane nanocomposites
The long-term efficacy of coronary or peripheral stenting is limited by in-stent restenosis (ISR), which occurs in 15 to 30% of patients and is attributed primarily to neointimal hyperplasia. By adding a drug-eluting coating, this rate has been reduced to about 5% or less. However, recently …
-
POSS-Based Biodegradable Polymers for Stent Applications: Electroprocessing, Characterization and Controlled Drug Release
… biodegradable polymers were investigated as stent coating for drug delivery from drug-eluting stents and as polymeric scaffold for fully bioabsorbable stents. A highly efficient and precise electrospraying technique, one of the electrostatic processing techniques, was developed for the stent …
-
Development and Evaluation of a Nanomatrix Coated Stent Using a Vascular Sheet With Atherosclerosis Model
While cardiovascular stent technology has considerable advances, there are hurdles to overcome due to the dysfunctional stented arteries which fail to maintain vascular homeostasis. Current stent designs ignored the significance of promoting functional artery healing (pro-healing). Therefore, we …
-
Bioactive surfaces for improved coronary stent performance
Drug eluting stents (DES) are widely used to treat coronary heart disease. Although current DES generally perform well, restenosis and delayed endothelium healing still remains an issue following stent implantations. Research efforts are now focused on the development of stent coatings that address …
-
The Immobilization of Ticagrelor on Implant Materials and Corrosion and Biofouling Inhibition by Novel Layered Polymer Thin Films for Marine Application
… accompanied by the insertion of a vascular stent. After the procedure patients are put on dual anti-platelet therapy (DAPT) to prevent stent thrombosis, a common complication to this procedure in which platelets aggregate in the blood vessel on the inserted stent. Systemic deactivation of …
-
Modeling and simulation of coronary stents: Intravascular drug delivery and arterial drug distribution
In-stent restenosis still occurs in coronary arteries implanted with drug-eluting stents, with the maximum thickness observed at the vascular site of maximum inter-strut angle. This phenomenon may be related to the specific spatiotemporal drug uptake in the arterial wall. In this work local …
-
Novel strategies for optimising drug release from medicinal implants
In-stent restenosis (ISR) is a significant limitation of percutaneous coronary revascularisation procedures, occurring in around 30% of patients. Implantation of the sent produces an intense inflammatory response. This leads to high levels of smooth muscle cell (SMC) proliferation and migration, …
-
A Bioinspired Multifunctional Nanomatrix for Cardiovascular Applications
… are constantly being researched and developed. Stents are a common therapeutic device for cardiovascular diseases that have undergone incrementally developmental changes over the last two decades. However, there are concerns about in-stent restenosis with bare metal stents and incomplete …
-
Synthesis and Functionality of Polymeric Diazeniumdiolates in the Use and Control of Nitric Oxide Release for Severe Medicinal Atherosclerotic Plaque Applications and Human Papillomavirus Treatment
… plaque. Earlier commercial use of coated stents in the pharmaceutical arena for arterial blockage showed great promise with the exception of remission of plaque buildup within the stent. The same procedure has been applied to relieve thrombogenic plaque, which has lead to restenosis …
-
Evaluation of in vivo endothelialization of VEGF coated stents with allogeneic mesenchymal stem cells
Deploying bare metal stents in the brain is a widely used procedure to repair damaged blood vessels for pathologies including aneurysms, vessel dissections and atherosclerosis. However, the major complication of this procedure is a stroke, which can occur in up to 11% of cases. The cause of the …
-
The safety and efficacy of novel dual function coronary stent in porcine model of myocardial infarction
… the effectiveness of a dual function coronary stent in both inhibiting In Stent Restenosis (ISR) and salvaging the injured myocardium following acute myocardial infarction in pigs. Background: For more than a decade, drug eluting stents have written a successful chapter in coronary …
-
DEVELOPMENT OF A DYNAMIC <i>IN VITRO<i> MODEL OF A STENTED BLOOD VESSEL TO EVALUATE THE EFFECTS OF STENT STRUT MATERIAL SELECTION AND SURFACE COATING ON SMOOTH MUSCLE CELL RESPONSE
… done in conjunction with the deployment of a stent. Stent deployment helps hold the vessel open following the local injury caused by balloon inflation and prevents elastic recoil and subsequent negative remodeling. Stenting has been shown to significantly reduce restenosis rates from …
-
Mise au point et évaluation de nouveaux revêtements de stents pour application cardio-vasculaire
… utilisé comme revêtement de stent métallique en Cobalt-Chrome. L’étude s’est déroulée en trois phase : 1/La production du polymère et la caractérisation physico-chimique, 2/L’évaluation in vitro et 3/L’évaluation in vivo dans plusieurs modèles. Dans un premier temps deux …
-
Synthèse et caractérisations de nouveaux polyesters biodégradables dérivés du poly (acide 3,3-diméthylmalique) comme revêtement prometteur de stents cardiovasculaires.
… de thèse s’articule autour de la resténose intra-stent qui représente la complication majeure de l’angioplastie par pose de stent dans les artères sténosées. Les stents actifs restent la solution actuellement utilisée pour le traitement de la resténose. Ce sont des stents métalliques recouverts …