Results 1 to 20 of 55 for “"Stent design"”
-
Improving Cardiovascular Stent Design Using Patient-Specific Models and Shape Optimization
Stent geometry influences local hemodynamic alterations (i.e. the forces moving blood through the cardiovascular system) associated with adverse clinical outcomes. Computational fluid dynamics (CFD) is frequently used to quantify stent-induced hemodynamic disturbances, but previous CFD studies have …
-
Coronary artery stent design for challenging disease: insights into patient specific modelling
… been a widely recognised tool for investigating stenting procedures. Initially, computer models of stenting were restricted to ideal vessels and in some cases by two dimensional analysis due to limited computational capabilities and resources. Nevertheless, nowadays, the increased computational …
-
Stent design and arterial mechanics: parameterization tools using the finite element method
Vascular stents are medical devices used to treat stenoses blockages in arteries that restrict blood flow. Most commonly, stents are made out of stainless steel or nitinol, and are delivered to the afflicted sites via catheter-based delivery systems. Usually, stents are balloon-expandable or …
-
An Evaluation of Proposed and Current Cardiovascular Stent Design Approaches to Aortoiliac Occlusive Disease
… bifurcation is commonly treated by arterial stenting. The most common practice of arterial stenting of aortoiliac occlusive disease is using balloon expandable stents. Traditionally, in order to prevent encroachment and/or occlusion of one iliac system by the stenting of the other, two …
-
Stented Artery Biomechanics: A Computational and In Vivo Analysis of Stent Design and Pathobiological Response
Vascular stents have become a standard for treating atherosclerosis due to distinct advantages in trauma and cost with other surgical techniques. Unfortunately, the therapy is hindered by the risk of a new blockage (termed restenosis) developing in the treated artery. Clinical studies have …
-
Vergleich der Offenheitsraten verschiedener selbstexpandierbarer Stentsysteme in der femoro-poplitealen Strombahn; hat das Stent-Design einen Einfluss?
… die 12-monatige TLR-Raten dreier verschiedener Stent-Designs – einem CC- (closed-cell), einem OC- (open-cell) und einem IW- (interwoven) designten Stent – nach Implantation in die femoro-popliteale Strombahn direkt miteinander verglich. Vorhergehende einarmige Studien erhärteten bereits den …
-
Image-Based Quantification Workflow for Coronary Morphology: A Tool for Use in Next-Generation Bifurcation Stent Design
… local hemodynamic alterations caused by current stenting approaches. Computational modeling of human arteries offers an attractive way to investigate the relationships between geometry, hemodynamics and vascular disease. Recent developments also make it possible to perform analysis on realistic …
-
Flow in the Vascular System Post Stent Implantation: Examining the Near-Stent Flow Physics to Guide Next-Generation Stent Design
… is often treated by the implantation of a stent, a wire mesh scaffold device placed in the region of an atherosclerotic plaque after balloon angioplasty. The stent was developed to improve the clinical outcome of angioplasty procedures by mitigating the effects of elastic recoil by the …
-
Morphological and stent design risks factors to prevent migration phenomena and type 1a endoleak for a thoracic aneurysm : A numerical analysis
… de déploiement complet d’un système de pose de stent ont été développées en utilisant la Méthode des Éléments Finis (FEM) afin d’étudier la stabilité du contact lors du largage d’une endoprothèse en nitinol dans un Anévrisme de l’Aorte Thoracique (AAT) réaliste. Les facteurs suivants associés à …
-
Design Exploration and Analysis of Carbon-Infiltrated Carbon Nanotube Vascular Stents
The purpose of this research was to design, develop, and test coronary stent designs composed of carbon-infiltrated carbon nanotubes (CI-CNTs). Coronary stents currently have two major complications: restenosis and thrombosis. CI-CNT stents have potential to address both of these issues, and …
-
Haemodynamic Assessment of Coronary Flow with CFD and Phase-Contrast MRI
… the likelihood of disease development, and stenting, a common treatment, has a high probability of restenosis and in-stent thrombosis. Coronary flow patterns, determined by vessel geometry and stent design and deployment, are thought to be related to adverse clinical outcomes. This thesis …
-
Design Validation of a Multi-Stage Gradually Deploying Stent
Angioplasty, or the use of rapidly deploying stents, is a common treatment for reopening narrowed vasculature often caused by atherosclerotic plaque. However, in-stent restenosis (ISR) induced by intimal hyperplasia is a common challenge to angioplasty. High impact stresses from current stent …
-
Design and Simulation of a Magnesium Based Biodegradable Stent for Hemodialysis Application
Stents are widely used as blood vessel scaffolding in medical applications, e.g., coronary stents. Stents can provide early stage scaffolding, increase blood flow, and optimize hemodynamics. Stainless steel is the most popular material for conventional stents and it has excellent mechanical …
-
EXPERIMENTAL AND COMPUTATIONAL STUDY ON THE EFFECTS OF FLOW DISRUPTIONS CAUSED BY STENTING AND IT’S IMPACT ON ACUTE STENT THROMBOSIS
Coronary stenting is the gold standard treatment of coronary artery disease. Stent thrombosis is a fatal complication of coronary stenting and is often associated with death or myocardial infarction. This study uses an in vitro benchtop flow perfusion model to study the impact of stent design, …
-
Characterization of the Embolisher, a device for cerebral embolic protection
… named "Embolisher". It consists of three parts; stent, deployment apparatus, and retrieval apparatus. The present research focuses on development of novel stent design and uses both experimental methods and numerical simulation of the blood flow during implementation of TAVI. Testing prototype of …
-
Computational Modelling of the Double Kissing Crush Technique in Coronary Bifurcation Stenting
… Double Kissing Crush (DKC) technique is the two-stent strategy with the strongest clinical evidence, yet its mechanical and haemodynamic performance is not fully understood. The interaction between stent design, procedural execution, and patient-specific anatomy also remains unclear, limiting …
-
Biomechanical Interaction Between Fluid Flow and Biomaterials: Applications in Cardiovascular and Ocular Biomechanics
… valves for an improved heart valve leaflet and stent design, and the interaction of an air-puff with anterior corneal surface to estimate IOP and characterize corneal biomechanics. While the two have very different natures, the governing equations and the backbone are very much the same.The …