Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 119 for “"Stent implantation"”
-
Percutaneous mitral valved stent implantation
… replacement of the native mitral valve by implantation of a valved stent via catheter technique in an off-pump procedure is still challenging. Though, the outcome with regard to para- and intravalvular leakages will presumably exceed todays percutaneous repair techniques. Here, a newly …
-
Biomechanical response of artery following stent implantation: Implication for restenosis
Stents have gained tremendous popularity over the past two decades, and their implantations in artery have become the most common surgical treatments for atherosclerosis-induced cardiovascular diseases (CVD). However, stent implantation could induce abnormal loading onto artery and trigger the …
-
The Development of a Computational Test-Bed to Assess Coronary Stent Implantation
The implantation behaviour of coronary stents is of great interest to clinicians and engineers alike as in-stent restenosis (ISR) remains a critical issue with the community. ISR is hypothesized to occur for reasons that include injury to the vessel wall caused by stent placement. To reduce the …
-
Promoting endothelialisation to reduce vascular injury following coronary angioplasty and stent implantation
… outcomes in patients undergoing angioplasty and stenting for coronary artery disease. I sought to establish a new cellular model to study the coronary endothelium in patients with acute myocardial infarction, and to utilise this model to identify novel polymer substrates that promote …
-
Proteomics Comparison of Extracellular Matrix Remodelling in Porcine Coronary Arteries upon Stent Implantation
… related to arterial injury and healing after stenting contributes to both, in-stent restenosis and thrombosis. Despite its important clinical implications little is known about ECM changes post-stent implantation. <br/><br/>METHODS Bare-metal (BMS) and drug-eluting stents (DES) were implanted …
-
Computational Fluid Dynamics Estimations of Wall Shear Stress Alterations Influencing Neointimal Hyperplasia After Stent Implantation
… pathology and 80% of such procedures involve stent implantation. As a result, over one million stents are deployed annually to restore blood flow distal to vascular stenoses. Unfortunately, approximately 30% of patients experience persistent vascular narrowing of the stented region within …
-
Percutaneous Aortic Valve ReplacementThe Anatomy of Aortic Root Structures and Postmortem Aortic Valve Stent Implantation
… made percutaneous and transapical aortic valve implantation a major challenge such as coronary flow impairment. In this study, the aortic root structures were observed and measured in human cadavers. Material and Methods: We assessed the diameter of the distal ascending aorta, the proximal …
-
Biodegradable versus multiple plastic stent implantation in benign biliary strictures: a systematic review and meta-analysis
… A colocação endoscópica de múltiplos stents plástico é frequentemente tida como o tratamento de primeira linha para esta patologia, apesar das limitações. Stents biliares biodegradáveis representam uma nova opção terapêutica para colmatar as falhas supramencionadas.ObjetivoAnalisar e …
-
The assessment of two year clinical outcomes after stent implantation for the treatment of coronary artery disease
The sirolimus-eluting stent (Cypher) was the first approved drug- eluting stent by the Food and Drug Administration in April 2003. This is a stent that is based on a bare-metal stent and is coated with a layer of polymer incorporating sirolimus and releasing it by diffusion. Drug-eluting stents …
-
Effect of intravascular ultrasound using on the rate of acute thrombosis and restenosis in drug-eluting stent implantation
… tedavisinde yaygın olarak kullanılan stentlerin takibinde enbüyük problem erken tromboz ve restenozdur. Şimdiye kadar hiçbir girişim erkenstent trombozu (ST) ve stent-içi restenozu (SİR) tamamıyla engelleyememiştir.Klinik çalısmalarda intravasküler ultrasonun (IVUS) stent yerleştirme …
-
Angiographische Analyse bei Patienten mit Stent-Implantation in den Hauptstamm der linken Koronararterie und Ballon-Angioplastie des Seitenastes
… distalen Bifurkation untersucht, inklusive Ein-Stent- und Zweistentstrategien. Die bisherigen Ergebnisse deuten an, dass die Einstentstrategie der Zweistentstrategie überlegen ist. Eine Strategie, in der die Stenose des Hauptstammes der linken Koronararterie mittels Stent-Implantation behandelt …
-
Flow in the Vascular System Post Stent Implantation: Examining the Near-Stent Flow Physics to Guide Next-Generation Stent Design
… the body. This condition is often treated by the implantation of a stent, a wire mesh scaffold device placed in the region of an atherosclerotic plaque after balloon angioplasty. The stent was developed to improve the clinical outcome of angioplasty procedures by mitigating the effects of elastic …
Page 1 of 6