Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 56 for “"Stent-Grafts"”

  1. Quantifying AAAs and developing FEA models for stent grafts

    … (EVAR) is preferred, via the introduction of a stent graft into the aneurysmal region. In this thesis, finite element analysis (FEA) techniques have been developed to model the AnacondaTM stent graft. The aim is to produce the necessary numerical tools to allow for personalized EVAR simulations …

    strathclyde Repository record for Quantifying AAAs and developing FEA models for stent grafts (opens in a new tab)

  2. Development of endovascular stent-grafts based on a nanocomposite polymer

    … properties in the development of endovascular stent-grafts. Methods: A self-expanding and sutureless aortic stent-graft was developed using nanocomposite polymer bonded to Nitinol. A new aortic model was designed for physiological assessment of stent-grafts and compliance and viscoelasticity …

    ucl Repository record for Development of endovascular stent-grafts based on a nanocomposite polymer (opens in a new tab)

  3. Roentgen stereophotogrammetric analysis to study dynamics and migration of stent grafts

    The technique of RSA to determine stent-graft migration and FRSA to study stent-graft dynamics are explained in further detail in CHAPTER 2. CHAPTER 3 and 4 concern the accuracy and feasibility of RSA to detect stent-graft migration in a static model and in a model with pulsatile motion. The …

    leiden Repository record for Roentgen stereophotogrammetric analysis to study dynamics and migration of stent grafts (opens in a new tab)

  4. Compressive mechanical behaviour of nitinol wires used in aortic stent grafts

    The Anaconda endovascular stent graft is a medical device designed to treat abdominal aortic aneurysms, composed of a nitinol wire structure and a fabric graft. The graft is required to undergo significant deformations before and after the implementation of the device. This thesis addresses the …

    strathclyde Repository record for Compressive mechanical behaviour of nitinol wires used in aortic stent grafts (opens in a new tab)

  5. Exploring the potential of stent-grafts derived from auxetic unit cells for endovascular applications

    … du flux sanguin à haute pression à l'aide d'un stent-graft (SG). Malgré son efficacité,l'EVAR est associée à un taux de complications significatif, notamment des endofuites, une migrationdu dispositif et une thrombose de la branche du greffon, conduisant à des interventions secondairesdans 19 % …

    star-france Repository record for Exploring the potential of stent-grafts derived from auxetic unit cells for endovascular applications (opens in a new tab)

  6. Análise de sensibilidade do comportamento à flexão de stent-grafts pelo método de elementos finitos

    … (EVAR), que faz uso de endopróteses do tipo stent-graft (SG), tem sido utilizada com sucesso desde a década de 90 como alternativa minimamente invasiva à cirurgia aberta de reparo de aneurisma. Os SG são constituídos, via de regra,de um esqueleto metálico (stents) fixado a um tubo flexível de …

    brazil-ufsc Repository record for Análise de sensibilidade do comportamento à flexão de stent-grafts pelo método de elementos finitos (opens in a new tab)

  7. Fluid Structure Interaction and Non-Newtonian Blood Flow in Stent Grafts for Abdominal Aortic Aneurysms

    … aortic repair (EVAR) where a polymer stent graft (SG) is used to redirect blood flow. Post operative concerns are common with EVAR like stent graft migration that are caused due to displacement forces acting on the ends of the SG. In this thesis, the aim is to correlate experimental …

    chalmers Repository record for Fluid Structure Interaction and Non-Newtonian Blood Flow in Stent Grafts for Abdominal Aortic Aneurysms (opens in a new tab)

  8. Μόλυνση-λοίμωξη επενδυμένων μεταλλικών ενδοναρθηκών κατιούσας θωρακικής και κοιλιακής αορτής (stent-grafts) αίτια, διάγνωση και αντιμετώπιση

    Οι ενδαγγειακές τεχνικές αποκατάστασης ανευρυσμάτων θωρακικής και κοιλιακής αορτής αποτελούν ευρέως αποδεκτές εναλλακτικές της ανοικτής χειρουργικής επέμβασης λόγω των περιορισμένων περιεγχειρουργικών επιπλοκών. Παρόλα αυτά μια σπάνια μεν αλλά δύσκολα αντιμετωπίσιμη επιπλοκή είναι η μόλυνση του …

    athens Repository record for Μόλυνση-λοίμωξη επενδυμένων μεταλλικών ενδοναρθηκών κατιούσας θωρακικής και κοιλιακής αορτής (stent-grafts) αίτια, διάγνωση και αντιμετώπιση (opens in a new tab)

  9. A computational fluid dynamics analysis of the distraction forces experienced by stent-grafts following fenestrated Endovascular Aneurysm Repair

    … Significant complications may be caused by stent-graft migration and component distraction which are both resisted by fixation force and provoked by haemodynamic distraction force. The hypotheses tested in this thesis are that larger angulation of vessels is associated with greater …

    liverpool Repository record for A computational fluid dynamics analysis of the distraction forces experienced by stent-grafts following fenestrated Endovascular Aneurysm Repair (opens in a new tab)

  10. Hemodynamic mathematical modelling for the evaluation of blood flow in fenestrated, branched and chimney endovascular aortic stent-grafts

    … to open surgery but the commercial endografts are not suitable for all thoracic and abdominal aortic aneurysms. The aneurysms with unfavorable morphological features require personalized treatment. Customized endografts preserve their fixation while conforming to hostile aortic anatomies …

    greece Repository record for Hemodynamic mathematical modelling for the evaluation of blood flow in fenestrated, branched and chimney endovascular aortic stent-grafts (opens in a new tab)

  11. Neue Stent-Graft-Designs in der Behandlung von thorakalen, thorakoabdominellen und abdominellen Aortenaneurysmen

    … endovaskuläre Therapie einschränkt. Neue Stent-Graft-Designs sollen die endovaskuläre Therapie in diesen Fällen verbessern oder ermöglichen. Im Fall von thorakalen Aortenaneurysmen sind die Hauptlimitationen einerseits die Morphologie der Zugangsgefäße und andererseits die Angulation des …

    fu-berlin Repository record for Neue Stent-Graft-Designs in der Behandlung von thorakalen, thorakoabdominellen und abdominellen Aortenaneurysmen (opens in a new tab)

  12. A novel foldable stent graft

    … concerns the structural design of medical stent grafts. A new type of an innovative stent graft has been developed. Unlike the conventional stent grafts which consist of a wire mesh and a covering membrane, the proposed stent graft can be made from a single folded sheet of material. …

    oxford Repository record for A novel foldable stent graft (opens in a new tab)

  13. The Effect of Endografts on the Propagation of Aortic Dissection: A Fluid-Structure Interaction (FSI) Finite-Element Model of Flow through the Descending Thoracic Aorta

    … trials on the use of minimally invasive stent-grafts to treat aortic dissection have proved promising. Though the precise etiology of aortic dissections is unclear, the underlying pathophysiology may be related to hypertension induced injury in an aorta that has lost compliance due to …

    umn Repository record for The Effect of Endografts on the Propagation of Aortic Dissection: A Fluid-Structure Interaction (FSI) Finite-Element Model of Flow through the Descending Thoracic Aorta (opens in a new tab)

  14. Interventions for portal hypertension in patients with portal vein occlusion and possible effects of a stent-graft on hepatic circulation

    … vein occlusion, require recanalization with stent or stent-graft often followed by additional TIPS. Stent-grafts used for TIPS, may occlude the outflow from the adjacent hepatic vein, potentially disturbing the circulation through the adjoining part of the liver. In paper I, results of …

    lund Repository record for Interventions for portal hypertension in patients with portal vein occlusion and possible effects of a stent-graft on hepatic circulation (opens in a new tab)

  15. Fabric modelling and effects of fluid flow disruption in endovascular devices

    … Endovascular aneurysm repair (EVAR) using stent grafts has become the preferred treatment method due to its minimallyinvasive nature. However, long-term complications including graft migration, endoleaks andthrombosis continue to occur and often require reintervention. This thesis …

    strathclyde Repository record for Fabric modelling and effects of fluid flow disruption in endovascular devices (opens in a new tab)

  16. Re-interventions after endovascular aortic repair: clinical and experimental studies

    … factors associated with additional iliac stent grafting. 3. To study flow-induced displacement forces in iliac limb stent grafts and the influence of stent graft angulation, fluid pressure, pulsation frequency, distal diameter of the stent graft, and asymmetric graft curvatures in an …

    goteborg Repository record for Re-interventions after endovascular aortic repair: clinical and experimental studies (opens in a new tab)

Page 1 of 3