Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 692 for “"Stents"”.

  1. Lebensqualitätsentwicklung nach Implantation von drug eluting stents im Vergleich zu bare metal stents

    … kann in selber Prozedur die Implantation von Stents erfolgen. Diese können unbeschichtet (bare metal stents = BMS) oder antiproliferativ beschichtet sein (drug eluting stents = DES). In folgender Arbeit steht die Evaluation der Lebensqualität (LQ) je nach implantiertem Stent im Vordergrund. …

    fu-berlin Repository record for Lebensqualitätsentwicklung nach Implantation von drug eluting stents im Vergleich zu bare metal stents (opens in a new tab)

  2. Τοποθέτηση ενδοπροθέσεων καλυμμένων με μόσχευμα (covered stents), εντός stents με επαναστένωση, σε λαγόνιες αρτηρίες

    Purpose: To evaluate the safety and efficacy of balloon-expandable covered stent (CS) for treatment of symptomatic iliac artery in-stent restenosis (ISR). Material and methods: This was a retrospective, single-arm, single-centre study, which included 25 consecutive patients referred for …

    greece Repository record for Τοποθέτηση ενδοπροθέσεων καλυμμένων με μόσχευμα (covered stents), εντός stents με επαναστένωση, σε λαγόνιες αρτηρίες (opens in a new tab)

  3. Design de stents entrançados multifuncionais

    Stents são estruturas tubulares para inserção nas artérias, apresentando-se como um dos principais tratamentos da aterosclerose coronariana obstrutiva. São fabricados principalmente em materiais metálicos, como o aço inoxidável, ligas de cromo-cobalto e Nitinol e atuam com o objetivo de exercerem …

    minho-thes Repository record for Design de stents entrançados multifuncionais (opens in a new tab)

  4. IVOCT imaging artifacts of coronary stents

    … and metallic and bioabsorable coronary stents were deployed with and without phantom neointima. High resolution Micro-CT images of the stent strut were recorded as a gold standard and utilized to create a three-dimensional representation of a strut that was imported into computer optical …

    texas Repository record for IVOCT imaging artifacts of coronary stents (opens in a new tab)

  5. Mechanisms of encrustation within ureteral stents

    … of obstruction. Despite their clinical success, stents often suffer from failures and side effects that impact on both patient’s quality of life and costs for national health services. One of the most common complications is encrustation of the stent’s surface caused by calcifications, and …

    soton Download PDF for Mechanisms of encrustation within ureteral stents (opens in a new tab)

  6. Prohealing Multifunctional Endothelium Nanomatrix Coated Stents

    … in the United States, and indeed, worldwide. Stents are the most commonly implanted devices used to treat cardiovascular disease. Bare metal stent use remains limited by relatively high rates of in-stent restenosis, a re-narrowing of the artery after stent deployment. Restenosis within stents …

    uab Repository record for Prohealing Multifunctional Endothelium Nanomatrix Coated Stents (opens in a new tab)

  7. Fibrous braided stents with antibacterial properties

    … disability in developed countries. Therefore, stents have emerged as a solution to overcome this problem. However, common commercialize stents, are metallic, which present several disadvantages as corrosion, higher risk of restenosis and infection. In order to minimize the disadvantages …

    minho-thes Repository record for Fibrous braided stents with antibacterial properties (opens in a new tab)

  8. Fabrication of TiNi thin film stents

    … for application as vascular implants, e.g. stents. The deposition of TiNi thin films on a cylindrical substrate employs a specific device which allows an in situ rotation of the substrate during the sputtering process and the use of a slit aperture to control the deposition angle. The …

    cau-kiel Repository record for Fabrication of TiNi thin film stents (opens in a new tab)

  9. Comparison of double-layered(ComVi) stents with polyurethane covered stents in palliative treatment of unresectable malignant gastroduodenal obstruction

    배경: 자가팽창형 금속스텐트는 악성 위십이지장 폐쇄의 고식적 치료에 현재까지 널리 사용되고 있다. 자가팽창형 금속스텐트에는 피막형과 비피막형의 두 가지 종류가 있는데, 비피막형 스텐트의 경우 종양의 내증식으로 인한 폐쇄가 빈번하다는 단점이 있으며, 피막형 스텐트의 경우 스텐트의 일탈이 문제가 되었다. 따라서 이 문제를 해결하기 위해 새로운 이중막 스텐트(ComVi)가 개발되었으며, 이는 피막형 스텐트 표면에 금속망을 더하여 종양의 내증식과 스텐트의 일탈을 동시에 줄일 수 있도록 고안되었다. 본 연구는 악성 위십이지장 폐쇄 환자에서 …

    ajou Repository record for Comparison of double-layered(ComVi) stents with polyurethane covered stents in palliative treatment of unresectable malignant gastroduodenal obstruction (opens in a new tab) Embargoed until 9999-12-31

  10. Development of adenoviral and miRNA eluting stents

    … despite the prolific use of intravascular stents within the clinic, there are significant problems associated with this revascularisation technique, such as in-stent restenosis (ISR) and late stent thrombosis (LST). ISR is the re-narrowing of arteries after stent deployment, characterised …

    glasgow Download PDF for Development of adenoviral and miRNA eluting stents (opens in a new tab)

  11. Graphene: the future of endografts and stents?

    Το γραφένιο, ένα δισδιάστατο νανο-υλικό που αποτελείται από άτομα άνθρακα με sp2 δεσμούς, έχει μια πληθώρα εξαιρετικών ιδιοτήτων. Το γραφένειο και τα παράγωγα του έχουν επιδείξει σημαντικές δυνατότητες σε πολλούς τομείς, συμπεριλαμβανομένης της αγγειοπλαστικής των στεφανιαίων αγγείων. Τα ήδη …

    athens Repository record for Graphene: the future of endografts and stents? (opens in a new tab)

  12. Τοποθέτηση μεταλλικών stents στον ουρητήρα - Υδροδυναμικές μεταβολές

    … metallic self-expandable and balloon expandable stents for the treatment of malignant ureteral obstruction. Materials and Methods: We treated 12 consecutive patients with malignant ureteral obstruction, for a total of 14 ureters with stents placed. We placed metallic balloon expandable stents in …

    greece Repository record for Τοποθέτηση μεταλλικών stents στον ουρητήρα - Υδροδυναμικές μεταβολές (opens in a new tab)

  13. Systemic review of the comparison of drug-eluting stents versus bare-metal stents for the management of femoropopliteal stenosis

    Στόχοι Η παρούσα μελέτη στοχεύει στη διεξαγωγή μιας επικαιροποιημένης συστηματικής ανασκόπησης τυχαιοποιημένων δοκιμών που ερευνούν τα αποτελέσματα της πρωτογενούς επαναγγείωσης με φαρμακοελευθερωτικό ενδονάρθηκα, σε σύγκριση με την επαναγγείωση με συμβατικούς μεταλλικούς ενδονάρθηκες σε ασθενείς …

    athens Repository record for Systemic review of the comparison of drug-eluting stents versus bare-metal stents for the management of femoropopliteal stenosis (opens in a new tab)

  14. Análise morfométrica digital na parede aórtica de suínos após implante de stents não revestidos versus stents revestidos com dacron

    Os stents são dispositivos intravasculares implantados com o objetivo de dilatar ou fixar a placa de colesterol contra a parede arterial. O objetivo avaliar dois tipos de stents de aço inoxidável, um recoberto com poliéster (dacron) e outro não recoberto, implantados na aorta infra-renal de suínos …

    brazil-ufrgs Repository record for Análise morfométrica digital na parede aórtica de suínos após implante de stents não revestidos versus stents revestidos com dacron (opens in a new tab)

  15. Development of Biodegradable Composite Materials for Coronary Stents

    Stents based on poly(L-lactic acid), PLLA, are very prominent in the field of biodegradable stents but a disadvantage of PLLA is its relative brittleness. Cardiologists have noted the occurrence of strut fracture during deployment of balloon expandable PLLA stents. Blends of PLLA and …

    auckland-ms Repository record for Development of Biodegradable Composite Materials for Coronary Stents (opens in a new tab)

  16. A system for impedance characterization of coronary stents

    Stents are used to re-open and maintain flow in diseased coronary arteries in patients suffering from coronary heart disease. Drug-eluting stents are now the preferred choice of stent but their performance is still limited by delayed healing of the important endothelial cell layer that lines the …

    strathclyde Repository record for A system for impedance characterization of coronary stents (opens in a new tab)

  17. Remote controlled drug release in drug-eluting stents

    … successful coronary intervention, drug-eluting stents are placed within obstructive arteries to restore blood flow to the heart and reverse life-threatening consequences. However, it is still plagued by the resurrection of artery occlusion, resulted by stent-induced restenosis.This battling and …

    strathclyde Repository record for Remote controlled drug release in drug-eluting stents (opens in a new tab)

Page 1 of 35