Investigation of Buildup Dose for Therapeutic Intensity Modulated Photon Beams in Radiation Therapy
… IMRT treatment modalities were compared. A brass step compensator was designed and built for the solid IMRT. Matching MLC step sequences were used for the MLC IMRT. This dissertation also presents the commissioning of a Monte Carlo code system, BEAMnrc, for a Varian Trilogy linear accelerator …