  1. THE INFLUENCE OF MACHINE MODEL AND OPTIMIZATION PARAMETERS ON THE GENERATION OF NARROW SEGMENTS IN STEP AND SHOOT INTENSITY MODULATED RADIOTHERAPY PLANS FOR SIMPLIFIED GEOMETRIES

    … of narrow segments is a matter of concern in step-and-shoot intensity modulated radiotherapy for several reasons. The measurement, calculation and delivery of dose from narrow segments may be complicated due to: the dosimetric properties of the detector; the effect of beam penumbra and …

    mcmaster Repository record for THE INFLUENCE OF MACHINE MODEL AND OPTIMIZATION PARAMETERS ON THE GENERATION OF NARROW SEGMENTS IN STEP AND SHOOT INTENSITY MODULATED RADIOTHERAPY PLANS FOR SIMPLIFIED GEOMETRIES (opens in a new tab)

  2. Assessment of Collimator Jaw Optimization In Reducing Normal Tissue Irradiation With Intensity Modulated Radiation Therapy

    … To evaluate normal tissue dose reduction in step-and-shoot intensity-modulated radiation therapy (IMRT) on the Varian 2100 platform by tracking the multileaf collimator (MLC) apertures with the accelerator jaws. Methods: Clinical radiation treatment plans for 10 thoracic, 3 pediatric and 3 …

    uthsc Repository record for Assessment of Collimator Jaw Optimization In Reducing Normal Tissue Irradiation With Intensity Modulated Radiation Therapy (opens in a new tab)

  3. Dynamic photon painting

    … radiosurgery is widely used for treating local and regional tumors. The key to improving the quality of radiosurgery is to increase the dose falloff rate from high dose regions inside the tumor to low dose regions of nearby healthy tissues and structures. Currently, most radiosurgeries rely on …

    unm Repository record for Dynamic photon painting (opens in a new tab)

  4. The effects of intrafraction motion on dose heterogeneity

    … (PWs), enhanced dynamic wedges (EDWs), and step-and-shoot intensity modulated radiation therapy (ssIMRT). Some of the effects of intrafraction motion can be eliminated with Gating Therapy. In this study, we have also investigated the efficiency of a Real-Time Position Management Gating …

    sask Repository record for The effects of intrafraction motion on dose heterogeneity (opens in a new tab)

  5. Design of x-ray source for real-time computed tomography

    … the need for managing the high thermal loads demanded by real-time CT (30 acquisition frames per second). To add to the current field of knowledge, two x-ray tube concepts are presented in this dissertation. First, a simulation of transient thermal analysis was performed on a compact …

    must-thes Repository record for Design of x-ray source for real-time computed tomography (opens in a new tab)

  6. Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc

    … well as complex treatments such as static-field step-and-shoot intensity modulated radiotherapy (sIMRT), volumetric modulated arc therapy (VMAT) and non-coplanar trajectory-based Dynamic Wave Arc (DWA) in a single MC run. Open-source Monte Carlo applications based on EGSnrc particle transport …

    ubc Repository record for Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc (opens in a new tab) Download PDF for Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc (opens in a new tab)

  7. Intensity modulation of therapeutic photon beams using a rotating multileaf collimator

    This thesis describes the development and implementation of a novel method of delivering intensity modulated radiation therapy (IMRT) that provides greater accuracy and spatial resolution than currently available methods. Through improvements in multileaf collimator (MLC) based fluence generation, …

    ubc Repository record for Intensity modulation of therapeutic photon beams using a rotating multileaf collimator (opens in a new tab) Download PDF for Intensity modulation of therapeutic photon beams using a rotating multileaf collimator (opens in a new tab)

  8. Optimization Methods for Patient Positioning in Leksell Gamma Knife Perfexion

    … Elekta, Stockholm, Sweden) to treat brain cancer and tumour patients. PFX is a dedicated head-and-neck radiation delivery device that is commonly used in clinics. In a PFX treatment, the patient lies on a couch and the radiation beams are emitted from eight banks of radioactive sources around the …

    toronto-retro Repository record for Optimization Methods for Patient Positioning in Leksell Gamma Knife Perfexion (opens in a new tab)

  9. Development of X-ray Coherent Scatter Projection Imaging Systems

    … systems are sensitive to material structure and chemical composition, and generate images with contrast superior to conventional transmission x-ray imaging. The goal of this thesis was to develop a scatter projection imaging system capable of acquiring images in less than ten minutes, in the …

    carleton Repository record for Development of X-ray Coherent Scatter Projection Imaging Systems (opens in a new tab)

  10. IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams

    … energy fluence distribution of the photon beam and make it suitable for clinical use. Recently, linacs without flattening fifilter (Flattening FilterFree - FFF) are increasingly used in radiotherapy because of its benefifits, e.g. high dose rate (2000 MU/min), reduced scattered and leakage …

    qucosa-diss

  11. Assessment of New Innovations In Pet/Ct For Respiratory Motion Correction

    … (PET/CT) is a vital tool used for stating and treatment response assessment of patients due to its ability to visualize and accurately quantify the bio-distribution of radiolabeled pharmaceuticals. However, due to the long acquisition times, respiratory motion blur is unavoidable in PET …

    uthsc Repository record for Assessment of New Innovations In Pet/Ct For Respiratory Motion Correction (opens in a new tab)

  12. CT-Koronarangiographie: Einfluss der Positionierung der Region of Interest beim Bolus-Tracking auf die Bildqualität

    … Studie erhielten eine CT-Koronarangiographie im Step-and-Shoot-Modus zum Ausschluss einer koronaren Herzkrankheit bei intermediärem Risiko. Mittels Propensity-Score-Matching wurden insgesamt 192 Patienten für die Studie ausgewählt: je 96 mit Positionierung der ROI im linken Vorhof bzw. in der …

    qucosa-diss

  13. Characterization of a Small Animal SPECT Platform for use in Preclinical Translational Research

    … an increased focus on developing an understanding of how fundamental processes used by imaging systems work to provide quantitative output for the imaging system. Isotopes like I-125 pose specific imaging problems that are a result of low energy emissions as well as how closely spaced those …

    utk-theses Repository record for Characterization of a Small Animal SPECT Platform for use in Preclinical Translational Research (opens in a new tab)

  14. Development and Optimization of a Dedicated Dual-Modality SPECT-CT System for Improved Breast Lesion Diagnosis

    … women newly diagnosed each year are misdiagnosed and undergo a biopsy. Current mammography techniques are limited by: (1) low image contrast, especially in women with dense breasts; (2) difficulty in diagnosing and detecting lesions close to the chest wall and in women with radiographically dense …

    duke Repository record for Development and Optimization of a Dedicated Dual-Modality SPECT-CT System for Improved Breast Lesion Diagnosis (opens in a new tab)