Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 103 for “"Stereomicroscope"”
-
Near-Infrared Silica-Based Gold Nanoshells as Potential Rapid Diagnostic Imaging Agents For Breast Cancer Tumor Detection
… was observed macroscopically through a standard stereomicroscope and confirmed microscopically through reflectance confocal microscopy and immunohistochemistry. These results suggest that anti-HER2-nanoshells used in tandem with a near-infrared reflectance confocal microscope and a standard …
-
A Reproducible Method to Assess Aligner Thickness Effect on Force Output
… scanning, and cross-sectional analysis under a stereomicroscope. All measurements were taken along the mid-sagittal plane of the facial surface of the upper right central incisor. Force output and variability both generally increased with an increase in material thickness. The range of measured …
-
Comprovação da real comunicação entre o endodonto e o periodonto através do canal cavo inter-radicular e sua prevalência em molares inferiores humanos
… junction. Then, they were examined in a stereomicroscope, where marks of the coloring were observed in the furcation and on the pulpar floor. After this recording, the sample was diaphanized and with the transparent teeth, it was possible to observe in the stereomicroscope, the true …
-
A statistical evaluation of several coding systems used to determine the degree of infestation of the shaft louse, Menopon Gallinae (Linn.) on chickens
… the lice after which counts were made using a stereomicroscope. The resulting numbers were subjected to several statistical tests which indicated that there are linear relationships between the numerical symbols and the infestations they arbitrarily represent. It was also found that due to the …
-
Photomicrography as an artistic medium
… utilizing either a compound microscope or stereomicroscope in conjunction with a digital single-lens reflex (SLR) camera and a microscopy lens attachment. Subjects for images consisted of a variety of live and dead coral specimen, algae, saliva, blood, marine vertebrates and invertebrates, …
-
THE INCIDENCE OF ROOT DENTINAL MICRO-CRACKS CAUSED BY RECIPROCATING AND CONTINUOUS ROTARY INSTRUMENTATION
… pictures were taken with a Zeiss Discovery V20 stereomicroscope before and after canal instrumentation. Each of the pre-instrumentation and post-instrumentation images were evaluated for dentinal defects by four calibrated endodontists utilizing REDCap survey. Using a chi-square analysis, there …
-
Comparación in vitro del desgaste compensatorio de tres instrumentos de acceso (Gates Glidden, IntroFile FlexMaster® y SX ProTaper®) utilizados en endodoncia
… results were analyzed in microns (µm) through a stereomicroscope with a Leica Microsystems 56D software. Results: Statistically significant differences between experimental groups were found. Introfile limes produce minor discrepancy of compensatory attrition. The main discrepancy was found in …
-
Understanding the association between the presence of occlusal fissure calculus and caries
… 12.5 megapixel cooled CCD camera mounted to a stereomicroscope (Leica S8APO). Scanning electron microscopy (EMITECH SC7620 Mini Sputter Coater and Hitachi TM3000 Tabletop Microscope) was used to assess the presence of calculus in the fissure. Varying amounts of calculus and caries were found in …
-
Εντοπισμένη διάβρωση κραμάτων αλουμινίου υψηλής αντοχής της σειράς 7xxx: συγκριτική μελέτη της επίδρασης των θερμικών κατεργασιών στην κινητική του φαινομένου
… corroded surfaces were assessed qualitatively by stereomicroscope observation and quantitative assessment by calculating the weight loss obtained after removal of corrosion products. Metallographic sections were also held to study and measure the depth of attack.
-
EPIBIONTS ON BRACHIOPODS FROM THE DEVONIAN DUNDEE FORMATION OF OHIO
… All the brachiopod shells were examined under a stereomicroscope for evidence of epibionts, and preferred host taxa were determined. Epibionts are absent on all the brachiopod shells except some Rhipidomella shells. Further examination of these Rhipidomella shells under 100x magnification showed …
-
Comparación in vitro de la microfiltración coronal en restauraciones clase I con ionómero de vidrio tipo II reforzados con resina (Vitremer™ y Ketac™ n 100)
… cut with a carborundum disk and evaluated by a stereomicroscope. Results were analyzed using tests of Mann-Whitney and Kruskal Wallis. Results: Statistically significant differences between the three groups (p = 0.000) were found. Ketac N-100 showed a higher microfiltration, with an average of …
-
Regional-scale climate-induced variation in ant physiology and morphology
… ant leg length morphology was measured using a stereomicroscope.
-
DEVELOPMENT OF STANDALONE 3D-PRINTED BIOACTIVE AND ANTIBACTERIAL DENTAL IMPLANTS
… of failed implants was performed using a stereomicroscope and scanning electron microscopy (SEM). Failure modes such as interlayer delamination, stress concentrations around thread regions, and internal defects, including gaps in the infill and perimeter zones caused by under-extrusion, …
-
An investigation into the compatibility of some irreversible hydrorocolloid impression materials and dental gypsum products
… By photographing the gypsum casts through a stereomicroscope at constant signification and using a constant light source, It was possible to produce a consistent, photomicrograph. The gypsum casts were photographed with black-and-white flu, and high-contrast prints obtained of the …
-
ECTOPARASITOFAUNA DA TRAIRA (Hoplias malabaricus) PROVENIENTE DE AÇUDES LOCALIZADOS NO MUNICÍPIO DE SUMÉ
… evaluation. The monogeneans were quantified in stereomicroscope (4X) and protozoans in Macmaster camera (10X). After searching for parasites, it was found that 35 (87.5%) of the 40 fish examined were parasitized by at least one parasite taxon. The ectoparasite fauna was characterized by the …
-
Assessing the vertical distribution of microplastics in the sediments of a MAR basin
… were then identified and characterized using a stereomicroscope and graticule. This data was then analysed and mapped using SPSS and QGIS software.
-
Glide path preparation of nine instrument Systems and their effect on final canal area in simulated canals
… preinstrumentation images were obtained using a stereomicroscope. Glide path preparation was performed by an endodontic resident using FlexoFiles, FlexoFiles mounted in M4 safety handpiece, rotary EndoMagic instruments, rotary K3 instruments, rotary PathFiles instruments, rotary Pre Shaper …
-
The influence of post material, post diameter and substance loss on the fracture resistance of endodontically treated premolars
… (α=0.05). Fracture modes were examined with a stereomicroscope at ×25 magnification and recorded. Fracture loads ranged from 954 ±135 N (1 residual wall-glass fiber-ISO 70) to 1286 ±202 N (1 residual wall-glass fiber-ISO 90). Teeth restored with titanium posts showed a statistically significant …
-
Adaptações morfológicas do trato digestório do peixe neotropical Steindachnerina notonota (Characiformes, Curimatidae) ao hábito alimentar detritívoro
… tract. All structures were observed in the stereomicroscope. The organs were fixed in 10% formalin and submitted to hematoxylin and eosin staining, and PAS - periodic acid Schiff (gill rakers, epibranchial organ, esophagus, stomach, midgut and hindgut) and analyzed by light microscopy. The …
-
SPATIAL AND TEMPORAL CHARACTERIZATION OF SKIN TREATMENT PRODUCT DISTRIBUTION ON THE SKIN USING FLORESCENT STEREOMICROSCOPIC IMAGING
… instrument, the Skicon. The technique utilized a stereomicroscope modified for fluorescence and a fluorescent indicator known as Glogerm(. Using image analysis the percentage fluorescence was calculated and used as an indication of the presence of water in the SC. This was based on the fact the …
Page 1 of 6