Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 64 for “"Stokes Parameters"”.

  1. Stokes parameters of skylight based on simulations and polarized radiometer measurements

    A method to calculate the Stokes parameters Q, U, as well as angle of polarization (AoP) from the new generation CIMEL Dual-Polar sun/sky radiometer CE318-DP polarized skylight measurements is developed in this thesis. Besides the degree of linear polarization (DoLP) and the total radiance I, the …

    qucosa-diss

  2. An In-Band OSNR Monitoring Method for Polarization Multiplexed QPSK Signals Using Stokes Parameters

    … for polarization multiplexed signals based on a Stokes polarimeter has been investigated through theoretical studies, simulations and measurements. For the measurements, a 90 degree hybrid based polarimeter was constructed and used for measurements on noise loaded 28 GBd DP-QPSK signals. The …

    chalmers Repository record for An In-Band OSNR Monitoring Method for Polarization Multiplexed QPSK Signals Using Stokes Parameters (opens in a new tab)

  3. Radiative transfer of ultrasound

    … contains single scattering and propagation parameters that are calculated using the elastic wave equation. Polarization effects are included through the introduction of an elastodynamic Stokes vector which contains a longitudinal Stokes parameter and four shear Stokes parameters similar to …

    uiuc Repository record for Radiative transfer of ultrasound (opens in a new tab)

  4. Fluorescence polarization of atomic, dissociated atomic, and molecular transitions induced by spin-polarized electron impact

    … performed regarding fluorescence polarizations (Stokes parameters) resulting from spin-polarized electron impact excitation of atoms. Measurement of fluorescence polarization provides insight into the angular momentum coupling that exists in the atomic state of interest. It also enables the …

    nebraska Repository record for Fluorescence polarization of atomic, dissociated atomic, and molecular transitions induced by spin-polarized electron impact (opens in a new tab)

  5. Sensitivity of the Mueller matrix to the optical and microphysical properties of cirrus clouds

    … method is employed to calculate the reflected Stokes parameters for cirrus cloud layers composed of different habits and effective sizes. The elements of the Mueller matrix are determined from the reflected Stokes parameters by considering four different incident polarization states. The …

    tamu Repository record for Sensitivity of the Mueller matrix to the optical and microphysical properties of cirrus clouds (opens in a new tab)

  6. Polarimetric Laser Measurement of Plant Leaves Under Different Physiological Conditions

    … conditioned leaves. In order to do that, Stokes parameters of maple leaves along with cottonwood leaves of various natural colors were measured and the result shows that these different colored leaves of the same species have distinct depolarization and degree of polarization pattern i.e., …

    sdstate Repository record for Polarimetric Laser Measurement of Plant Leaves Under Different Physiological Conditions (opens in a new tab)

  7. Angular momentum partitioning and hexacontatetrapoles in impulsively excited argon ions

    … electron impact. We measured the integrated Stokes parameters of the light emitted along the direction of the electron polarization from the excited ions without detecting the scattered electrons. The excited states under investigation, 2F7/2, 2F 5/2, 2D5/2, and 2P3/2 , have a 3p4 (1D) core …

    nebraska Repository record for Angular momentum partitioning and hexacontatetrapoles in impulsively excited argon ions (opens in a new tab)

  8. Shape measurement of single nanoparticles in water using optical microcavities

    … the shape information of the particle. Three Stokes parameters are measured to characterise the polarisation state of the transmitted light through the optical microcavity, deviating from the incident circularly-polarised light. With the theoretical model constructed, the …

    oxford Repository record for Shape measurement of single nanoparticles in water using optical microcavities (opens in a new tab)

  9. A study of the polarimetric characteristics of planar chiral mesoscopic structures

    … states are mathematically analyzed using Stokes parameters and Muller matrices. In order to minimize the measurement time, the microscope polarimeter was optimized by using LabView to collect the experimental data and using Python for analyzing the data during the overdetermined …

    salford Download PDF for A study of the polarimetric characteristics of planar chiral mesoscopic structures (opens in a new tab)

  10. Exploitation of infrared polarimetric imagery for passive remote sensing applications

    … plate array in order to generate the so-called Stokes parameters: S_0, S_1, S_2, and DoLP. Current research in this area has shown the ability of using such variations of these parameters to detect smooth manmade structures in low contrast contrast scenarios. This dissertation proposes and …

    njit Repository record for Exploitation of infrared polarimetric imagery for passive remote sensing applications (opens in a new tab)

  11. Iceberg Detection Using Compact Polarimetric Synthetic Aperture Radar

    … covariance matrix. Detection using the Stokes parameters is also tested, both through the use of the skew-normal distribution to model the Stokes vector ocean clutter, and also by using the Stokes parameters to calculate the orientation and ellipticity of the polarization ellipse. A …

    calgary Repository record for Iceberg Detection Using Compact Polarimetric Synthetic Aperture Radar (opens in a new tab)

  12. Electron impact excitation of 2p states in atomic hydrogen

    … employed to simultaneously measure the reduced Stokes parameters P1,P2 and P3, which are needed to fully characterise the state of the atom immediately after the collision. This has also allowed the excitation coherence parameter P+ to be determined directly. In the case of the excitation of 2p …

    maynooth Download file for Electron impact excitation of 2p states in atomic hydrogen (opens in a new tab)

  13. Coherence studies of geomagnetic fluctuations in the frequency range .05 to 10 Hz

    … field at each site was conducted in terms of Stokes parameters.

    nps Repository record for Coherence studies of geomagnetic fluctuations in the frequency range .05 to 10 Hz (opens in a new tab)

  14. Identification of Geostationary Satellites Using Polarization Data from Unresolved Images

    … relating image intensity at the two cameras to Stokes parameters S0 and S1. After the system calibration, polarization data was collected during three nights on eight geosynchronous satellites built by various manufacturers and launched several years apart. Three pairs of the eight satellites …

    denver Repository record for Identification of Geostationary Satellites Using Polarization Data from Unresolved Images (opens in a new tab)

  15. Crosstalk and noise in division-of-focal-plane polarimeters and polarization imaging applications

    … crosstalk affects the reconstruction of the Stokes parameters. Experimental data is presented confirming the presented mathematical model and further emphasizing the detrimental effects of crosstalk on estimation of relevant polarization parameters for biomedical applications using …

    uiuc Repository record for Crosstalk and noise in division-of-focal-plane polarimeters and polarization imaging applications (opens in a new tab)

  16. Polarization Ray Tracing

    … vary over many wavelengths. In Chapter 9 3D Stokes parameters are defined by expanding the coherence matrix with Gell-Mann matrices as a basis. The definition of nine-by-nine 3D Mueller matrix is presented. The 3D Mueller matrix relates the incident 3D Stokes parameters to the exiting 3D …

    arizona-thes Repository record for Polarization Ray Tracing (opens in a new tab)

  17. Polarimetric thermal imaging

    … by rotating the plate about its vertical axis. Stokes parameters were computed from the irradiance images. Images of intensity, degree of polarization and polarization angle were derived from the Stokes parameters. The dependence of these polarization characteristics on viewing angle was …

    nps Repository record for Polarimetric thermal imaging (opens in a new tab)

  18. Modelling polarized light for computer graphics

    … as an inherent attribute of light, using the Stokes parameters. A reflection model is developed within this framework and the implementation within a global illumination algorithm called Photon is presented.</p>

    iastate Repository record for Modelling polarized light for computer graphics (opens in a new tab)

  19. Spectropolarimetric Analysis of Circumstellar Mass Flows

    … rather obscure mathematical formulation of the Stokes parameters presented in Chandrasekhar's book on radiative transfer. As a result most theoreticians and observers embark upon research careers with the knowledge that there exist four Stokes parameters, but unaware of their physical …

    glasgow Download PDF for Spectropolarimetric Analysis of Circumstellar Mass Flows (opens in a new tab)

  20. A High Time Resolution Study of the Radio Emission from Pulsars

    … 2010). By analysing the covariances between the Stokes parameters in these archival data, we discovered several rare polarisation phenomena. In particular, the Arecibo data included a highly sensitive observation of the first- discovered pulsar, PSR B1919+21 (also known as PSR J1921+2153), which …

    auckland-tech Repository record for A High Time Resolution Study of the Radio Emission from Pulsars (opens in a new tab)

Page 1 of 4