Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 364 for “"Stopped-flow"”.
-
Computer interfaced stopped-flow kinetics
Stopped-flow kinetics is a method in which two reactants are forced into a mixing chamber and their flow abruptly stopped. The progress of the reaction is monitored at an observation window, a short distance from the chamber along the flow path. Traditionally, data from the stopped-flow has been …
-
Automated Analysis by Stopped-Flow Methodology
Extensions to the stopped-flow analyzer have been developed that demonstrate capabilities which offer the stopped-flow method as an attractive alternative for dedicated chemical analysis. The instrumentation has been designed to expand the versatility of the stopped-flow method, exploiting its …
-
Stopped-flow analysis : automation and application
Thesis (M.S.)--Michigan State University. Department of Chemistry, 1983
-
Scanning stopped-flow studies of amp-aminohydrolase and tryptophanase
Thesis (Ph. D.)--Michigan State University. Department of Chemistry, 1983
-
Stopped-flow kinetics of the ammonation of cis-Dichlorodiamminepalladium (II).
… of sodium chloride was studied using stopped-flow techniques. An analysis of the following system was completed and discussed in the light of experimental rate constants.
-
Application of an automated stopped-flow system in clinical analysis
Thesis (Ph. D.)--Michigan State University. Department of Chemistry, 1978
-
Basic and practical investigations of automated stopped-flow mixing systems
Thesis (Ph.D.) - Michigan State University. Department of Chemistry
-
Stopped-Flow Studies of Reactions of Chromium(VI) and Iron(III)
Stopped-flow devices have been constructed and are described. Using this technique reactions of iron(lll) and chromium(VI) with organic substrates in aqueous perchlorate media have been investigated. Iron(IIl) has been found to react in the form of Fe3+ (aq) and FeOH2+ (aq) with both …
-
Automated Clinical/analytical Methodologies Developed for a Stopped-Flow Spectrophotometric System
Made available in DSpace on 2014-12-13T20:10:25Z (GMT). No. of bitstreams: 1 7820983.pdf: 7729717 bytes, checksum: d08b7f2b6a85c850a4a76aaa271ee1dc (MD5) Previous issue date: 1978
-
A stopped-flow study of the protonation of aromatic radical anions
Thesis (Ph. D.)--Michigan State University. Department of Chemistry, 1970
-
Rapid-scanning stopped-flow studies of the reduction of cytochrome c oxidase
Thesis (Ph. D.)--Michigan State University. Department of Chemistry, 1981
-
An automated, computer-controlled stopped-flow spectrophotometer for fast reaction-rate analysis
Thesis (Ph. D.)--Michigan State University. Department of Chemistry,
-
A Stopped-Flow Analyzer for Kinetic Methods Development - Automated Implementation of Guggenheim's Methods
… single-beam spectrophotometer into a versatile stopped-flow kinetic analyzer. A relatively inexpensive microcomputer system serves as a dedicated controller/data processor for the instrument. The design employed features preservation of the optical configuration and geometry of the original …
-
Clinical-Scale Hyperpolarization of 129Xe and 131Xe via Stopped-Flow Spin Exchange Optical Pumping
… keeping polarizations high, particularly in a “stopped-flow” polarizer environment. This dissertation is divided into eight main chapters. The first chapter is written to provide a historical context for the SEOP field and summarize the evolutionary stages that have led to current methodologies. …
-
Applications of stopped-flow mixing in heteropolymolybdate kinetics studies and in reaction-rate determinations
Thesis (Ph.D.)--Michigan State University. Department of Chemistry, 1982
-
The design and application of a vidicon rapid scanning spectrophotometer to stopped-flow kinetics
Thesis (Ph.D.) - Michigan State University. Department of Chemistry
-
Effect of Ethylene and Propylene on Performance of Ziegler - Natta Catalyst in Stopped - Flow Polymerization
… kopolymery byly připraveny za použití techniky „stopped-flow“. Pro tento účel byla zkonstruována vysokotlaká polymerační „stopped-flow“ aparatura, která umožňuje syntézu kopolymerů PP-blok-EPR za podmínek blízkých podmínkám v průmyslových reaktorech pro výrobu komerčních ICP materiálů. Aparatura …
-
Development and Characterization of a Stopped-Flow-Bypass Analysis System With Applications To Biochemical Measurements
A new apparatus called Bypass Trapped Flow Analysis System (ByT-FAS) is described. A properly designed ByT-FAS gives an analyst the ability to use analyte sample volumes of 10 to 200 μL [or more] and reagent volumes of approximately the same size. The sample and reagent are injected into their …
Page 1 of 19