Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 128 for “"Stopping power"”.

  1. A Theoretical Model for Calculation of Molecular Stopping Power

    … is employed to obtain a formula to evaluate the stopping power of many useful molecular systems. The stopping power of H2 and He gas was calculated for incident proton energy ranging from 100 KeV to 2.5 MeV. The stopping power of O2, N2 and water vapor was also calculated for incident proton …

    odu Repository record for A Theoretical Model for Calculation of Molecular Stopping Power (opens in a new tab)

  2. The stopping power of various elements for protons of moderately low energies

    The stopping power of a material Is defined as the space-rate of loss of energy suffered by a particle of nuclear or atomic dimensions in its passage through the material. Since the time of Thomson and Rutherford the subject has been investigated both theoretically and experimentally in its many …

    nps Repository record for The stopping power of various elements for protons of moderately low energies (opens in a new tab)

  3. Dual-Energy Computed Tomography for Accurate Stopping-Power Prediction in Proton Treatment Planning

    Derzeitige Reichweiteunsicherheiten in der Protonentherapie verhindern das vollständige Ausschöpfen ihrer physikalischen Vorteile. Ein wesentlicher Anteil ist dabei auf die Vorhersage der Reichweite mittels Röntgen-Computertomographie (CT) zurückzuführen. Um die CT-bezogene Unsicherheit zu …

    qucosa-diss

  4. Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography

    Accurate estimation of the proton stopping power ratio (SPR) is important for treatment planning and dose prediction for proton beam therapy. The state-of-the-art clinical practice for estimating patient-specific SPR distributions is the stoichiometric calibration method using single-energy …

    wustl Repository record for Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography (opens in a new tab)

  5. Improving relative stopping power calibration in X-ray treatment planning CT using sparse proton radiographies

    … irradiated tissue to stop ions, i.e., the tissue stopping power, needs to be determined to a high degree of accuracy. Currently, treatment planning is based on an X-ray computed tomography (CT) of the patient acquired prior to treatment, which is converted to stopping power relative to water based …

    lmu-germany Repository record for Improving relative stopping power calibration in X-ray treatment planning CT using sparse proton radiographies (opens in a new tab)

  6. THE STOPPING POWER OF WATER: ARE MARITIME STATES MORE LIKELY TO BUCK-PASS THAN LAND POWERS?

    … The thesis explores the issue of whether land powers are more likely to balance against Chinese military capabilities than island nations; it is intended to determine if the differences in strategic behavior are related to the geographic setting of various states. The thesis asks if maritime …

    nps Repository record for THE STOPPING POWER OF WATER: ARE MARITIME STATES MORE LIKELY TO BUCK-PASS THAN LAND POWERS? (opens in a new tab)

  7. The Stopping Power of Amorphous and Channelled Silicon at All Energies as Computed with the Binary Encounter Approximation

    … binary encounter approximation to calculate the stopping power of protons penetrating silicon. The main goal of the research was to make predictions of the stopping power of silicon for low-energy and medium-energy channelled protons, in the hope that this will motivate experiments to test the …

    unt Repository record for The Stopping Power of Amorphous and Channelled Silicon at All Energies as Computed with the Binary Encounter Approximation (opens in a new tab)

  8. Evaluation and Clinical Implementation of a Dual-Energy CT Stopping-Power Ratio Mapping Technique for Proton-Therapy Treatment Planning

    … of the Bragg-peak position from predicted stopping-power ratio maps. The method that is most commonly used in today’s clinical practice for predicting stopping-power ratio (SPR) consists of a stoichiometric calibrationtechnique based on single-energy CT (SECT) for direct estimation of …

    wustl Repository record for Evaluation and Clinical Implementation of a Dual-Energy CT Stopping-Power Ratio Mapping Technique for Proton-Therapy Treatment Planning (opens in a new tab)

  9. Monte Carlo Modeling of Ion Beam Induced Secondary Electrons

    … incorporated with a reliable database of stopping power tables, for wide variety of range of materials, there have been numerous attempts to experimentally measure ion stopping power tables and to tabulate the data. Experimental data for pure elements and compounds is almost totally absent …

    utk-theses Repository record for Monte Carlo Modeling of Ion Beam Induced Secondary Electrons (opens in a new tab)

  10. Measurement of the stopping powers of liquids and vapours for alpha-particles

    … have been carried out of the molecular stopping power for alpha- particles over the energy range 1 to 8 Mev of oxygen, water, methyl, ethyl and propyl alcohols, dichloromethane, trichloromethane and carbontetrachloride in the liquid and vapour states, These results are compared with …

    city-london Download PDF for Measurement of the stopping powers of liquids and vapours for alpha-particles (opens in a new tab)

  11. Improving the quality of proton CT scan images by utilizing straggling power.

    … that combining two forms of collected data, stopping power and scattering power, may result in a sharper image. Initial testing harnessed typical filtering techniques to improve the combined image, but did not result in sharpened boundaries. Further testing harnessed knowledge of the data …

    baylor Repository record for Improving the quality of proton CT scan images by utilizing straggling power. (opens in a new tab)

  12. Physics Effects in Single-Photon Emission Computed Technology (SPECT) Detectors

    … detector would have a large area with excellent stopping power and high count rate capability, in addition to excellent energy and spatial resolution. Semiconductor detectors are an emerging technology that have three of these ideal attributes: high stopping power, excellent energy and spatial …

    arizona-thes Repository record for Physics Effects in Single-Photon Emission Computed Technology (SPECT) Detectors (opens in a new tab)

Page 1 of 7