Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Storey drift"”.

  1. Analytical study on upgrading the seismic performance of nominally ductile RC frame structures using different rehabilitation techniques

    … lateral deflection, ductility demand, and inter-storey drift are the most commonly used damage state indices. The objective of this study is to analytically investigate the effectiveness of different rehabilitation patterns in upgrading the seismic performance of existing non-ductile RC frame …

    concordia Download PDF for Analytical study on upgrading the seismic performance of nominally ductile RC frame structures using different rehabilitation techniques (opens in a new tab)

  2. Seismic Performance and Shear Strengthening of Precast Hollow-core Floors

    … common flooring system in New Zealand's multi-storey building stock. Due to their extrusion manufacturing process, these floor units lack transverse shear reinforcement, making them prone to non-ductile failure mechanisms during earthquakes. The 2016 M-7.8 Kaikoura earthquake showed that these …

    auckland-ms Repository record for Seismic Performance and Shear Strengthening of Precast Hollow-core Floors (opens in a new tab)

  3. Strain Rate Effects on a Ductile Moment Resisting Frame with RBS Connection Subjected to Seismic Ground Motions

    … only a slight decrease in mean predicted inter-storey drift is observed when strain rate dependent material properties are used in analyses. It is observed that MRF with RBS connections can experience a maximum strain rate up to 0.30 per second. The strain hardening factor at RBS center is found …

    carleton Repository record for Strain Rate Effects on a Ductile Moment Resisting Frame with RBS Connection Subjected to Seismic Ground Motions (opens in a new tab)

  4. Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών διασυνδεδεμένων πλαισίων με χρήση τριών νέων μεθόδων

    … induce certain damage levels in terms of inter- storey drift ratio (IDR) and local ductility of the frame members (μ). According to SEAOC, target damages are linked with various performance levels. As a next step of the procedure, modal damping ratios that correspond to first four modes, are …

    greece Repository record for Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών διασυνδεδεμένων πλαισίων με χρήση τριών νέων μεθόδων (opens in a new tab)

  5. Seismic performance of plane moment resisting frames with concrete filled steel tube columns and steel I beams

    … the maximum roof displacement, the maximum inter-storey drift ratio, the maximum rotation ductility along the height of the frame and the behavior factor are developed.Comparison of the proposed design method with those adopted by current seismic design codes demonstrates that the proposed …

    greece Repository record for Seismic performance of plane moment resisting frames with concrete filled steel tube columns and steel I beams (opens in a new tab)

  6. Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system

    … on buildings with torsional irregularity, a four-storey reinforced concrete (RC) structure with torsional irregularity is considered for Vancouver seismicity condition. SAP2000 software is used to conduct Linear Dynamic Analysis (LDA) and Non-Linear Time History Analysis (NLTHA) using eight …

    ubc Repository record for Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system (opens in a new tab) Download PDF for Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system (opens in a new tab)

  7. Seismic performance of CLT structures with base isolation

    … acceleration of the top story, inter-story drift) of base-isolated buildings to that of a reference CLT structure with fixed base. The SAP2000 software was used to conduct the nonlinear time history analysis of 3-, 6-, and 12-story CLT structures under three types of ground motions that may …

    uvic Repository record for Seismic performance of CLT structures with base isolation (opens in a new tab)

  8. Seismic Fragility Analysis of Reinforced Concrete Shear Wall Buildings in Canada

    … as seismic intensity parameters and the first storey drift was selected as the engineering demand parameter which was further refined for irregular cases. The earthquake records were scaled to capture the structural behaviour under different levels of seismic excitations known as Incremental …

    ottawa-retro Repository record for Seismic Fragility Analysis of Reinforced Concrete Shear Wall Buildings in Canada (opens in a new tab)

  9. Semiactive Friction Connections for Seismic Control of Multi-Storey Buildings

    … for control of the seismic response of multi-storey buildings, and the mechanisms behind their performance. Passive and semiactive systems are novel strategies used to reduce the seismic demand in structural systems by increasing the energy dissipation capacity and altering the dynamic …

    whiterose Download PDF for Semiactive Friction Connections for Seismic Control of Multi-Storey Buildings (opens in a new tab)

  10. Experimental evaluation of the seismic performance of hollow-core floors and retrofits

    … retrofits were tested under bi-directional inter-storey drift loading. The tested floors exhibited an early onset of cracking in the unreinforced webs of the hollow-core units at 0.4% –0.5% inter-storey drift. With increasing drifts, the web cracks also tended to become shallower (i.e. <<45 …

    auckland-ms Repository record for Experimental evaluation of the seismic performance of hollow-core floors and retrofits (opens in a new tab)

  11. The influence of structural details, geotechnical factors and environs on the seismic response of framed structures.

    … which mobilise different amounts of inter-storey drift, local rotation and global rotation response. The influence of soil structure interaction (SSI) and frame rigidity (i.e. the properties of the joints) on the response behaviour is investigated. The finite element database is then used …

    dundee Repository record for The influence of structural details, geotechnical factors and environs on the seismic response of framed structures. (opens in a new tab) Download PDF for The influence of structural details, geotechnical factors and environs on the seismic response of framed structures. (opens in a new tab)

  12. Development of A New Self-centring Low-damage Bracing System for Earthquake Resistant Structures Using Resilient Slip Friction Joints (RSFJs)

    … the structure (such as permanent deformation and storey-drift, strength and stiffness deterioration/loss and so on). Dealing with all of those repercussions on the scale of an urban area or a city with many buildings will put extra burden and demand on the local and national economy in the …

    auckland-tech Repository record for Development of A New Self-centring Low-damage Bracing System for Earthquake Resistant Structures Using Resilient Slip Friction Joints (RSFJs) (opens in a new tab)

  13. Residual Capacity and Repairability of Reinforced Concrete Frame Buildings

    … relatively low to moderate, over 60% of multi-storey RC buildings in the Christchurch central business district were demolished due to insufficient insurance coverage and significant uncertainty in the residual capacity and repairability of those buildings. This observation emphasized an …

    auckland-ms Repository record for Residual Capacity and Repairability of Reinforced Concrete Frame Buildings (opens in a new tab)

  14. Seismic design procedure for steel moment resisting frames with viscous dampers

    … peak forces that are out of phase with the peak drifts of elastic or mildly inelastic structures.Steel moment-resisting frames (MRFs) with viscous dampers are prone to plastic mechanisms that involve hinges in columns because of the large column axial forces due to the large damper forces and …

    greece Repository record for Seismic design procedure for steel moment resisting frames with viscous dampers (opens in a new tab)

  15. System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls

    … deformations along the height of multi-storey systems, introduces complexities in the interpretation of global response parameters such as inter-storey drift, structural stiffness, and force distribution among structural elements. This study investigates the impact of floor diaphragm …

    ottawa-retro Repository record for System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls (opens in a new tab)

  16. Element Exchange Algorithms for Optimum Viscous Damper Placement in Buildings

    … for three case studies include (1) an eight-storey RC MRF building where the centre of mass (CM) is deliberately varied to test the optimised designs’ usability against symmetric and asymmetric structures, (2) a ten-storey RC MRF building used to validate the usability of optimised design at …

    auckland-ms Repository record for Element Exchange Algorithms for Optimum Viscous Damper Placement in Buildings (opens in a new tab)

  17. Performance of shape memory alloy reinforced concrete frames under extreme loads

    … Canada are taken into consideration. For each storey type, three different reinforcement detailings have been considered, namely: i) steel reinforcement only (Steel RC); ii) SMA rebar used in the plastic hinge region of the beams and steel rebar in other regions (Steel-SMA RC); and iii) the …

    ubc Repository record for Performance of shape memory alloy reinforced concrete frames under extreme loads (opens in a new tab) Download PDF for Performance of shape memory alloy reinforced concrete frames under extreme loads (opens in a new tab)

  18. Semi-Active Control of Post-tensioned Steel Frames

    … for improving the seismic behaviour of multi-storey steel frame buildings. Three control approaches were proposed to improve the dynamic behaviour of post-tensioned frames: (i) energy dissipation approach which aims to increase the energy dissipation capacity of the frame, (ii) stiffness …

    whiterose Download PDF for Semi-Active Control of Post-tensioned Steel Frames (opens in a new tab)

  19. Network-synthesis-based identification methodology for passive vibration suppression system design

    … IFL and 2PT1NG networks are applied to a three-storey building to reduce its inter-storey drift. The GIFN network is used to design hydraulically interlinked suspensions for vehicles. Simulation results show that the proposed approach is effective in identifying beneficial vibration suppression …

    bristol Repository record for Network-synthesis-based identification methodology for passive vibration suppression system design (opens in a new tab) Download PDF for Network-synthesis-based identification methodology for passive vibration suppression system design (opens in a new tab)

  20. Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών πλαισίων με ιδιομορφικούς συντελεστές συμπεριφοράς και τρεις στάθμες επιτελεστικότητας

    … have been scaled properly in order the interstorey drift or ductility demands to comply with the targeted performance levels, as they are specified in SEAOC2000 or FEMA. The purpose of this research is the construction of an equivalent, linear multi - degree of freedom system, which …

    greece Repository record for Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών πλαισίων με ιδιομορφικούς συντελεστές συμπεριφοράς και τρεις στάθμες επιτελεστικότητας (opens in a new tab)

Page 1 of 2