  1. Static Response and Failure Prediction of Anisotropic Material Extrusion Polymer Parts

    … Correlation (DIC) tool to analyze full-field strain measurements and capture the elastic mechanical response of PEEK polymer specimen, our study establishes a strain-based failure criterion that defines the critical strain failure boundary.

    washington Repository record for Static Response and Failure Prediction of Anisotropic Material Extrusion Polymer Parts (opens in a new tab)

  2. Influence of stress state dependency on ductile fracture modeling in standard test specimens using LS-dyna explicit analysis

    … with optimization. An implementation of a strain-based, stress state dependent failure criterion for a ductile material is validated through simulations of standard experiments. For a strain-based failure criterion, the strain required to reach fracture depends on the material, rate of …

    ohiolink Repository record for Influence of stress state dependency on ductile fracture modeling in standard test specimens using LS-dyna explicit analysis (opens in a new tab)

  3. Structural response of fiber-polymer composite bending-active elastica members under short- and long-term loading conditions

    … a structural typology whose geometry is based on the elastic deformation of initially straight members that, in the case of beams, is known as elastica. This configuration involves applying horizontal displacements to a sliding support, causing a beam to be bent into an arched shape. …

    epfl Repository record for Structural response of fiber-polymer composite bending-active elastica members under short- and long-term loading conditions (opens in a new tab)

  4. Evaluation of a Press Fit, Percutaneous, Skeletally Anchored Endoprosthesis for Prosthetic Limb Attachment: Bone Response and the Effect of Low Intensity Vibration

    … shown to be an indication of osseointegration failure. Finite element modeling predicted that bone-endoprosthesis press fits greater than 50 µm would cause bone damage at endoprosthesis implantation and the amount of damage would increase over the subsequent 24 hours after surgery. The finite …

    ohiolink Repository record for Evaluation of a Press Fit, Percutaneous, Skeletally Anchored Endoprosthesis for Prosthetic Limb Attachment: Bone Response and the Effect of Low Intensity Vibration (opens in a new tab)

  5. Uncertainty analysis in rock mass classification and its application to reliability evaluation in tunnel construction

    … Traditional deterministic design methods are based on a limited understanding of this inherent uncertainty, which may result in over- or under- design of underground structures. To address this issue, a systematic assessment of uncertainties in rock mass classification systems has been …

    colo-mines Repository record for Uncertainty analysis in rock mass classification and its application to reliability evaluation in tunnel construction (opens in a new tab)