In vitro Untersuchung der Primärstabilität des Straumann® BLX Implantatsystems in einem Sinusbodenelevationsmodell
… und dem Vergleich der Primärstabilität des Straumann® BLX Implantat Systems mit Straumann® tapered effect (TE) Implantaten. Hierfür wurde ein Sinusboden-Elevationsmodell und gleichzeitiges Implantatinsertionsmodell in frisch geschlachteten Rinderrippen erstellt. In der Studiengruppe wurden …
-
Αξιολόγηση δύο αμιγώς ολοκεραμικών διαβλεννογονίων εμφυτευματικών τμημάτων εσωτερικής ένωσης: ITI Straumann – Xive, Friadent
… IPS e.max, ITI Dental Implant System, Institute Straumann AG, Waldenburg, Switzerland and (b) Dentsply, Friadent, Xive Cercon Abutment Straight. One specimen from each implant system was evaluated for the inter-proximal contacts between ceramic abutment and internal surfaces of the main implant …
-
O papel da proteína derivada da matriz do esmalte (Straumann emdogain) no processo de cicatrização de defeitos periimplantares
… das proteínas derivadas da matriz de esmalte (STRAUMANN ® EMDOGAIN).
-
Influencia de la estabilidad primaria de los implantes dentales straumann tissue level standard en los procedimientos restauradores de carga inmediata.
La utilización de los implantes dentales en el tratamiento rehabilitador de pacientes desdentados es hoy una práctica común en las clínicas dentales. La alta predictibilidad del tratamiento con implantes realizando carga diferida temprana, tiempo de esper
-
Comparative Evaluation of Bending Resistance and Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study
… Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study Hammad Ul Haq B.D.S. Objective: To compare the mechanical performance of Locator® (Zest Anchors) and Novaloc® (Straumann) implant overdenture attachment systems connected to Straumann Bone Level …
-
Early marginal bone loss around three different implant systems: prospective cohort study
… loss around three different implant systems (Straumann Bone Level. Noble Biocare Replace, 3i Biomet Certain) and compare them to each other in a prospective clinical study using clinical and radiographic measurements. MATERIALS AND METHODS: Twenty-three patients were recruited for the study. …
-
Estudio clínico prospectivo de casos control de los implantes de aleación titanio-circonio (roxolid® straumann®) en pacientes con diabetes mellitus tipo 2
… de aleación Titanio - Circonio (Roxolid® Straumann®) de diámetro estrecho (3,3 mm) en pacientes diabéticos tipo 2 (DM2) en restauraciones unitarias, comparándolo con un grupo control de pacientes sin diabetes mellitus. Se analiza la tasa de éxito y supervivencia, la pérdida ósea marginal y …
-
The effect of multiple tightening and untightening on abutment screw and driver head dimensions
… tips in three implant systems: Nobel Biocare, Straumann, and ZimVie. An in vitro experimental study was conducted using thirty new abutment screws (n = 10 per implant system) and manufacturer-specific drivers. Implant analogs were embedded in polymethyl methacrylate (PMMA) pattern resin blocks …
-
THE ANALYSIS OF EMDOGAIN BINDING AFFINITY FOR DIFFERENT PARTICULATE BONE GRAFT MATERIALS.
… INC, Cerritos, CA) and Emdogain (Institut Straumann AG, Basel, Switzerland). The biologically inactive nature of many commercially available bone graft materials provides an opportunity for the addition of certain biologic materials to enhance the healing response. The development of an …
-
PROTESI PARZIALE FISSA, IMPLANTO-SUPPORTATA A CARICO IMMEDIATO: STUDIO PROSPETTICO
… 8 patients were rehabilitated with 20 implants (Straumann RN TL 4.1x10mm) and immediate FPD. 9 patients were rehabilitated with 20 implants (Straumann RN TL 4.1x10mm) and early loading protocol. We analyze bone density according to Lekholm and Zarb classification, implant torque during …
-
Retrospective review of pre surgical variables associated with marginal bone loss measured at 2nd stage abutment surgery for endosseous dental implants
… systems were included in the study design. Straumann Bone Level Tapered SLActive and Nobel Biocare Replace Conical Connection. Implants were placed by the same resident from the Periodontics department. Clinical measurements of bone level were recorded at the time of placement and then again …
-
TITANIUM AND ZIRCONIA PARTICLE RELEASE FROM IMPLANT SURFACES DURING ER: YAG LASER DECONTAMINATION
… Methods: Six (N=6) Ti-Zirconium alloy (Roxolid®; Straumann® USA) and six (N=6) yttra-stabilized tetragonal zirconia (PURE® Ceramic; Straumann® USA) machined material discs, as well as two (N=2) expired Ti sandblasted acid-treated implants (Ti SLA® Implant; Straumann USA) and two (N=2) expired …
-
Immediate Loading Of 4 Guided Implants Supporting A Maxillary Overdenture Using A Novaloc Retention System
… (Roxolid®, SLActive®, 3.75mm diameter, Institut Straumann AG, Basel, Switzerland) to support an immediately loaded overdenture. Implants were connected with Novaloc® attachments (Institut Straumann AG, Basel, Switzerland) immediately following surgery if insertion torque (IT) reached 20 N/cm or …
-
The influence of compressive cyclic loading on the retention of cast crown copings cemented to implant abutments.
… Method Cast crown copings were cemented to Straumann synOcta titanium implant abutments with three different readily used and available cements. Specimens were placed in a humidifier, thermocycled and subjected to one of four quantities of compressive cyclic loading. The uniaxial tensile …
-
Importancia de la apertura bucal para cirugía guiada de implantes dentales. Reporte de caso y recomendaciones.
… longitudes mediante el protocolo guiado Straumann®.
-
Der Einfluss von Implantatgeometrie und Implantatoberfläche auf den Implantat-Knochen-Verbund : eine vergleichende Analyse im Schafsmodell
… Oberfläche verwendet (BL-SLA, Straumann). Für die experimentelle Studie wurde das Beckenmodell beim Schaf gewählt. Es wurden insgesamt 21 Implantate pro Gruppe inseriert. Je 7 Implantate einer Gruppe wiesen eine Implantationsdauer von entweder 2, 4 und 8 Wochen auf. Während der …
-
Estudio retrospectivo comparativo a 10 años entre la influencia de la superficie de titanio con arenado y grabado ácido convencional (SLA) o hidrófilo (SLActive) y la pérdida ósea marginal en el implante dental
… del implante y la MBL alrededor de implantes Straumann® durante un período de seguimiento de hasta 10 años tras la carga protésica. Material y Método: Se llevó a cabo un estudio multicéntrico retrospectivo en las Facultades de Odontología de Sevilla y de Valencia, evaluando la MBL y la pérdida …
-
Alveolar Bone Characteristics of Well-Controlled Versus Poorly-Controlled Diabetic Patients
… 8 Type II DM patients received a 4.1x10 mm Straumann Roxolid implant in a posterior mandible site. Conclusions: Within the first 6 months, all implants yielded similar early implant stability, survival and success rates in poorly and well controlled Type II DM individuals according to the …
-
Accuracy of Implant Placement Utilizing Stereolithographic Guides Printed with and without Cross-arch Stabilization Struts
… a 3.3x10mm Bone Level Tapered (BLT) implant (Straumann). Ten surgical guides were designed utilizing a stabilization strut (Group A), while ten guides were designed without the stabilization strut (Group B). Twenty guides total, ten in each group, were 3-D printed and 5 mm sleeves were …
-
A prospective analysis of success and survival of haptic robotically driven dental implant placement.
… least 1 year of functional loading of the same Straumann (Basel, Switzerland) titanium dental implants that were placed with the r-CAIS workflow. Materials and Methods: Since acquisition of the Yomi® robotic system, a comprehensive list of patients who underwent dental implant therapy via r-CAIS …