Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Stray flux"”.

  1. Stray Flux Monitoring and Multi-Sensor Fusion Condition Monitoring for Squirrel Cage Induction Machines

    … investigates the ability of external magnetic flux-based condition monitoring to detect rotor-related faults and incipient stage bearing faults in squirrel-cage induction machines (SCIMs). This work also discusses the multisensory synergy of the external magnetic flux measurement with other …

    gatech Repository record for Stray Flux Monitoring and Multi-Sensor Fusion Condition Monitoring for Squirrel Cage Induction Machines (opens in a new tab)

  2. Saturation Effects in 3p3L Power Transformers due to Geomagnetically Induced Currents

    … forms balanced return paths which oppose the dc flux evenly in each limb, thereby neutralising the effect. The challenge is this theory only remains true if the circuit resistance of the three-phase lines connected to the transformer are balanced, which has proven difficult to achieve in …

    cape-town Repository record for Saturation Effects in 3p3L Power Transformers due to Geomagnetically Induced Currents (opens in a new tab)

  3. Investigation of passive magnetic shielding methods combining bulk superconductors and coated conductors

    … are generally character- ized by high values of stray flux densities potentially detrimental to their environment. In this context, it is necessary to screen these devices by means of effective magnetic shields. Large flux densities in the low frequency regime (typically < 100 Hz) cannot be …

    liege Repository record for Investigation of passive magnetic shielding methods combining bulk superconductors and coated conductors (opens in a new tab) Download PDF for Investigation of passive magnetic shielding methods combining bulk superconductors and coated conductors (opens in a new tab)

  4. Condition Monitoring and Fault Detection for Electrical Machines Using Advanced Sensing Techniques Based on Fibre Bragg Gratings

    … in three 2.2kW induction motors (IMs) using stray flux in a non-invasive manner. Optical fibre is immune to electromagnetic interference (EMI) which is an advantage but limits its direct use for magnetic field sensing. A magnetostrictive transducer, terfenol-D was bonded to FBG to form a …

    aston Download PDF for Condition Monitoring and Fault Detection for Electrical Machines Using Advanced Sensing Techniques Based on Fibre Bragg Gratings (opens in a new tab)

  5. Power transformer magnetization under GIC/GMD

    … core. Two significant effects are the abnormal stray flux in transformers and extremely large harmonic contents in excitation currents, which can lead to serious equipment damage and power system misoperation. Such incidents have occurred during the March 1989 K-9 solar magnetic disturbance. …

    vt Repository record for Power transformer magnetization under GIC/GMD (opens in a new tab)

  6. Measurements and finite element modelling of transformer flux with dc and power frequency current

    … which could lead to overheating due to excessive stray flux. Finite element matrix (FEM) modelling software is of considerable use in transformer engineering as it is able to solve electromagnetic fields in transformers. For many problems, typically involving only specific parts of a transformer, …

    cape-town Repository record for Measurements and finite element modelling of transformer flux with dc and power frequency current (opens in a new tab)

  7. Condition monitoring of high efficiency heating, ventilation and air conditioning systems

    … brushless DC, or BLDC, fan motor, followed by a stray flux spectrum analysis, which increases reliability in detecting an unbalanced load condition. Static eccentricity and dynamic eccentricity are two of the main faults commonly found in the rotor of a BLDC motor. An improved method for …

    gatech Repository record for Condition monitoring of high efficiency heating, ventilation and air conditioning systems (opens in a new tab)

  8. Core Loss Calculation in Amorphous High Frequency High-Power Transformers with Different Topologies

    … proportional to the frequency of the applied flux and, hence, a HFHP transformer can be expected to be much lighter in comparison with the same transformer operating at power frequency. Increasing the frequency of the applied voltage and currents thus has a large impact on the transformer. The …

    chalmers Repository record for Core Loss Calculation in Amorphous High Frequency High-Power Transformers with Different Topologies (opens in a new tab)

  9. Experimental investigations of a recent fluxgate theory

    A recent theory describes the fluxgate magnetometer as a modulated inductor. In that theory, hysteresis and demagnetization are implicitly incorporated in the sense-coil inductance, an easily measured quantity. In this thesis, the principle equation of that theory is experimentally tested. …

    ubc Repository record for Experimental investigations of a recent fluxgate theory (opens in a new tab) Download PDF for Experimental investigations of a recent fluxgate theory (opens in a new tab)

  10. Remanent state noise in particulate magnetic recording media

    Remanent state noise is the variation in stray flux emanating from a magnetic recording medium which is in a remanent state of magnetisation. A portion of this noise is related to the magnetic microstructure of the recording medium. This study had two main objectives. The first was to devise and …

    cent-lancashire Download PDF for Remanent state noise in particulate magnetic recording media (opens in a new tab)

  11. Mitigation of Remanence Flux in Power Transformers using Predetermined Method of De-Energization

    … (especially finite analyses) to the point that stray flux, eddy current, hysteresis loss and harmonic loss (embodied and represented within the non-linear Rₚ element and known as “core Watt losses”) have all attained significant improvements witnessed by their 99.8+ percent efficiency. The …

    umkc Repository record for Mitigation of Remanence Flux in Power Transformers using Predetermined Method of De-Energization (opens in a new tab)

  12. New techniques for electric machine diagnostics using advanced signal processing and machine learning.

    … methods, such as vibration, search-coil airgap flux, and stray-leakage flux sensors. To overcome the diagnostic drawbacks of statistical ML classifiers and classical approaches, transfer learning (TL) was applied to fine-tune deep convolutional neural network (CNN) models pretrained on …