Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 99 for “"Stress Shielding"”.

  1. A three-dimensional finite element method for quantifying stress shielding following total hip replacement

    … of femoral stem loosening is believed to be stress shielding of the proximal femur following implantation. In order to ensure the long-term success of total hip replacement, minimization of stress shielding is desirable. Since currently available femoral prostheses vary markedly in both …

    rice Repository record for A three-dimensional finite element method for quantifying stress shielding following total hip replacement (opens in a new tab)

  2. Computational Framework for Designing Patient-specific, 3D-printable, and Stress-shielding Resistant Pelvic Implants

    … to implant loosening is bone resorption due to stress-shielding. This phenomenon occurs in peri-prosthetic bone when the stiffer implant shields the less stiff bone from the mechanical stimuli required for maintaining healthy bone density. Incorporating porosities in implants using 3D-printable …

    rice Repository record for Computational Framework for Designing Patient-specific, 3D-printable, and Stress-shielding Resistant Pelvic Implants (opens in a new tab)

  3. Stress Shielding Minimized In Femoral Hip Implants A Finite Element Model Optimized By Virtual Compatibility

    … As the new femoral hip implant transmits reduced stresses to the remaining bone, bone tissue atrophies at the interface, permitting loosening of the implant, pain, and thereby obliging additional surgery to correct the issue (Meade). In the present work, a methodology is endeavored for creating an …

    ucf Repository record for Stress Shielding Minimized In Femoral Hip Implants A Finite Element Model Optimized By Virtual Compatibility (opens in a new tab)

  4. The effect of modular tapered fluted stems on proximal stress shielding in the human femur.

    … systems using tapered fluted stems on proximal stress shielding in the human femur is the focus of this study. Seven modular implants were press-fit into seven femurs, where there was little or no contact between the modular body and the test femur. Finally, hydroxyapatite bone cement was added …

    louisville Repository record for The effect of modular tapered fluted stems on proximal stress shielding in the human femur. (opens in a new tab)

  5. Finite element analysis of orthopaedic plates and screws to reduce the effects of stress shielding

    … to bone resorption. This phenomenon, known as stress shielding, is a common cause of failure in fracture fixation of long-bones. Using finite element models, this thesis studies the effects of implant geometry and material properties in relation to stress shielding, by examining bone-implant …

    ottawa-retro Repository record for Finite element analysis of orthopaedic plates and screws to reduce the effects of stress shielding (opens in a new tab)

  6. Finite Element Analysis of Total Knee Arthroplasty

    … to be a problematic aspect of the procedure. Stress shielding induced by different design parameters of the implant has generated controversy in the determination of an ideal configuration. The purpose of this study is to investigate how implant design parameters – fixation technique, stem …

    calpoly Repository record for Finite Element Analysis of Total Knee Arthroplasty (opens in a new tab)

  7. A Finite Element Analysis of Tibial Stem Geometry for Total Knee Replacements

    … the influence of tibial stem geometry on stress shielding of the tibia for patients with a total knee replacement. Finite element analysis was used to study different tibial stem geometry types, as well as a vast array of different geometric sizes. Both a peg and stem type geometry were …

    calpoly Repository record for A Finite Element Analysis of Tibial Stem Geometry for Total Knee Replacements (opens in a new tab)

  8. Design d’une prothèse de resurfaçage de hanche en matériau composite biomimétique : mise au point d’outils d’évaluation numérique

    … femoral component. However, this could generate stress shielding (understressed bone tends to resorb, thus destabilizing the implant and causing aseptic loosening) in the femoral head, which could compromise the implant long term stability. The use of a biomimetic composite material with …

    ets-quebec Download PDF for Design d’une prothèse de resurfaçage de hanche en matériau composite biomimétique : mise au point d’outils d’évaluation numérique (opens in a new tab)

  9. Numerical optimisation of biomedical implant characteristics for increased service life.

    … technique with the aim to decrease implant stress shielding which in turn could increase Total Hip Arthroplasty (THA) service life and reduce patient discomfort by employing a distributed stiffness along implant length. Research found that through distributing stiffness along THA stem …

    adelaide Repository record for Numerical optimisation of biomedical implant characteristics for increased service life. (opens in a new tab)

  10. A Study on the Effects of Cementless Total Knee Arthroscopy Implants' Surface Morphology with Finite Element Analysis

    … of friction, between implant and bone. Stress shielding is a comparison of the properties in implanted bone to natural bone; it is a commonly used measurable when using a finite element model to optimize implant design. The purpose of this study is to investigate how different coating …

    calpoly Repository record for A Study on the Effects of Cementless Total Knee Arthroscopy Implants' Surface Morphology with Finite Element Analysis (opens in a new tab)

  11. Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion

    … but long-term complications such as stress shielding and aseptic loosening can lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective at reducing stress shielding; however, there is a lack of research on customized porous …

    greece Repository record for Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion (opens in a new tab)

  12. The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems

    … outcomes of THA are generally good. However, the stress shielding of the periprosthetic femur is a factor that can contribute towards the premature loosening of the femoral stem. In order to improve the stress shielding characteristics of metallic femoral stems, stiffness configurations that offer …

    wlv Repository record for The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems (opens in a new tab) Download file for The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems (opens in a new tab)

  13. The Strain Distribution in the Proximal Femur: A Method for Evaluation of New Femoral Component

    … many researchers that disuse atrophy caused by stress shielding of the upper femur after implantation of the femoral component is the primary cause of bone resorption in the calcar region. The purpose of this study was to evaluate the effectiveness of a prototype prosthesis, that incorporates a …

    clemson Repository record for The Strain Distribution in the Proximal Femur: A Method for Evaluation of New Femoral Component (opens in a new tab)

  14. Analyse numérique de la technique de resurfaçage de la hanche métal-métal : effet du positionnement et de la fixation de la composante fémorale sur les contraintes dans l'os

    … de la masse osseuse dans la tête fémorale due au stress shielding. But: La présente étude concerne le positionnement de la composante fémorale et sa fixation. L'influence de l'alignement vams-valgus sur les contraintes dans l'os est d'abord investiguée. Ensuite, l'épaisseur du manteau de ciment …

    ets-quebec Download PDF for Analyse numérique de la technique de resurfaçage de la hanche métal-métal : effet du positionnement et de la fixation de la composante fémorale sur les contraintes dans l'os (opens in a new tab)

  15. Imaging-based customization of lattice structures for biomedical applications

    … with young active patients. Bone cement and stress shielding have been identified as the major reasons for premature artificial joint failures. A breakdown of the cement may happen and revision surgery may be needed because of the aseptic loosening. The stress shielding problem is caused by …

    missouri Repository record for Imaging-based customization of lattice structures for biomedical applications (opens in a new tab)

  16. Processing, surface integrity, and performance of biodegradable magnesium-calcium implants by laser shock peening

    … stainless steel, or cobalt-chromium alloys cause stress shielding when left permanently in place. Stress shielding arises when metal implants carry the majority of stress because of their much higher Young's modulus than that of bone. As a consequence, bones are in a reduced stress state which …

    alabama Repository record for Processing, surface integrity, and performance of biodegradable magnesium-calcium implants by laser shock peening (opens in a new tab)

  17. Computational design of functionally graded hip implants by means of additively manufactured porous materials

    … the bone resorption due to the reduction of the stresses in the bone caused by the presence of the implant (stress shielding), and the interfacial failure caused by inadequate stress distribution at the bone-implant interface. While stiff implants increase stress shielding, flexible implants …

    ets-quebec Download PDF for Computational design of functionally graded hip implants by means of additively manufactured porous materials (opens in a new tab)

  18. Topology Optimization for Additive Manufacturing: from Mechanical Components to Orthopaedic Implants

    … to alleviate the existing clinical issue of “stress shielding” , pertinent to current state-of-the-art implants, through new designs using topology optimization. We propose a novel topology optimization formulation that is capable of addressing regional stress levels in bone by manipulating …

    jhu Repository record for Topology Optimization for Additive Manufacturing: from Mechanical Components to Orthopaedic Implants (opens in a new tab)

  19. Accounting for parameter uncertainties in the prediction of porous femoral stem reliability

    … loosening is reported to occur mainly due to stress shielding. Revision surgery can greatly hamper the standard and quality of life of those affected. To improve the reliability of the porous femoral stems, a probabilistic analysis has been performed on porous femoral stem designs …

    ttu Repository record for Accounting for parameter uncertainties in the prediction of porous femoral stem reliability (opens in a new tab)

  20. Finite element analysis of total knee replacement considering gait cycle load and malalignment

    … developed using MSC/ADAMS and MSC/MARC software. Stress shielding was found in the distal femur in the implanted knee joint. The stresses and strains in the distal femur were found to increase with body weight, especially during the stance phase. Serious stress shielding and more bone loss appear …

    wlv Repository record for Finite element analysis of total knee replacement considering gait cycle load and malalignment (opens in a new tab) Download file for Finite element analysis of total knee replacement considering gait cycle load and malalignment (opens in a new tab)

Page 1 of 5