Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 60 for “"Sub-Nyquist"”.

  1. Wideband spectrum sensing using sub–Nyquist sampling

    … even though the signals are sampled at sub-Nyquist rates using Compressive Sampling (CS), the recovery algorithms used by them are different from that of CS. In WCRR, a simple correlation function is used for the detection of carrier frequencies and in a mixed analog digital system, a …

    nwu-za Repository record for Wideband spectrum sensing using sub–Nyquist sampling (opens in a new tab)

  2. Leveraging waveform structure for sub-Nyquist signal processing in mmWave applications

    … Power consumption by ADCs scales linearly with sub-GHz sampling speeds and quadratically with above GHz sampling speeds. In our solution, we leverage the waveform structure of the systematically and cooperatively designed pilot signals transmitted by multiple sources. We develop AoA estimation …

    texas Repository record for Leveraging waveform structure for sub-Nyquist signal processing in mmWave applications (opens in a new tab)

  3. Sub-Nyquist Rate Sampling Data Acquisition Systems Based on Compressive Sensing

    … fundamental theory and design procedure of the sub-Nyquist rate sampling receiver front-end that exploits signal sparsity by employing Compressive Sensing (CS) techniques. The CS receiver serves as an Analog-to-Information Conversion (AIC) system that works at sampling rates much lower than the …

    tamu Repository record for Sub-Nyquist Rate Sampling Data Acquisition Systems Based on Compressive Sensing (opens in a new tab)

  4. K-t-sub-Nyquist sampled parallel echo planar imaging in MRI

    With k-t-sub-Nyquist sampling, dynamic magnetic resonance imaging (MRI) measurements become more efficient, since time-consuming gradient encoding steps are omitted. Efficiency is yet only guaranteed, if the imaging information can be reconstructed without compromising the spatio-temporal …

    freiburg-diss Repository record for K-t-sub-Nyquist sampled parallel echo planar imaging in MRI (opens in a new tab)

  5. SUB-NYQUIST SENSING AND SPARSE RECOVERY OF WIDE-BAND INTENSITY MODULATED OPTICAL SIGNALS

    … below those dictated by the traditional Shannon-Nyquist sampling theorem, it is possible to make more efficient use of the samples collected and detect a limited number of reflecting targets using specialized recovery algorithms without reducing system resolution. Through theoretical derivations, …

    maryland Repository record for SUB-NYQUIST SENSING AND SPARSE RECOVERY OF WIDE-BAND INTENSITY MODULATED OPTICAL SIGNALS (opens in a new tab)

  6. Sub -Nyquist Multicoset and MIMO Sampling: Perfect Reconstruction, Performance Analysis, and Necessary Density Conditions

    We then study the MIMO sampling problem, where a set of multiband input signals is passed through a MIMO channel and the outputs are sampled nonuniformly. MIMO sampling is motivated from applications like multiuser communications and multiple source separation. MIMO sampling encompasses several …

    uiuc Repository record for Sub -Nyquist Multicoset and MIMO Sampling: Perfect Reconstruction, Performance Analysis, and Necessary Density Conditions (opens in a new tab)

  7. The Dynamic Sub-Nyquist Sampling Model for Compressive Sampling Based Music Information Retrieval-Design, Analysis and Implementations

    … signal-to-information converter to acquire the sub-Nyquist sampling data. Thirdly, we identify efficient features, which are invariant to time and frequency distortions, and test different data search algorithms to optimise search efficiency. Finally, we conduct various simulations to establish …

    kings Repository record for The Dynamic Sub-Nyquist Sampling Model for Compressive Sampling Based Music Information Retrieval-Design, Analysis and Implementations (opens in a new tab) Download PDF for The Dynamic Sub-Nyquist Sampling Model for Compressive Sampling Based Music Information Retrieval-Design, Analysis and Implementations (opens in a new tab)

  8. Compressive techniques for sub-Nyquist data acquisition & processing in vibration-based structural health monitoring of engineering structures

    … is to resolve the above issues by considering sub-Nyquist data acquisition and processing techniques that involve simultaneous signal acquisition and compression before transmission. This drastically reduces the sampling and transmission requirements leading to reduced power consumptions up to …

    city-london Download PDF for Compressive techniques for sub-Nyquist data acquisition & processing in vibration-based structural health monitoring of engineering structures (opens in a new tab)

  9. Low-cost sub-Nyquist sampling hardware and algorithm co-design for wideband and high-speed signal characterization and measurement

    … that shows that characterizing signals with sub-Nyqusit sampling rate is feasible. Chapter 3 introduces a low-cost time-domain waveform reconstruction technique, which requires no mutual synchronization mechanisms. This brings down cost significantly and enables the implementation of systems …

    gatech Repository record for Low-cost sub-Nyquist sampling hardware and algorithm co-design for wideband and high-speed signal characterization and measurement (opens in a new tab)

  10. Resolving frequency ambiguities in step: frequency compressive receivers

    … that a stepped-frequency digital design using sub-Nyquist sampling mitigates many of the limitations. An algorithm that implements the Chinese Remainder Theorem to solve the frequency ambiguities that occur in the design due to sub-Nyquist sampling with high resolutions is investigated. …

    nps Repository record for Resolving frequency ambiguities in step: frequency compressive receivers (opens in a new tab)

  11. Sampling and reconstruction of seismic wavefields in the curvelet domain

    … problem, namely a sparsifying transform, a sub-Nyquist sampling strategy that subdues coherent aliases in the sparsifying domain, and a data-consistent sparsity-promoting program. After a brief overview of the curvelet transform and our seismic-oriented extension to the fast discrete …

    ubc Repository record for Sampling and reconstruction of seismic wavefields in the curvelet domain (opens in a new tab) Download PDF for Sampling and reconstruction of seismic wavefields in the curvelet domain (opens in a new tab)

  12. Non-Null Interferometer for Testing of Aspheric Surfaces

    … in the manufacturing of soft contact lenses. Sub-Nyquist interferometry was used to allow for large wavefront departures which generate high fringe frequency interferograms to be both captured and unwrapped. The sparse array sensor at the heart of the Sub-Nyquist technique sets limits on both …

    arizona-thes Repository record for Non-Null Interferometer for Testing of Aspheric Surfaces (opens in a new tab)

  13. DSP algorithm and system design for UWB communication systems

    … Analog-to-Digital Converter (ADC) working at sub-Nyquist sampling rate. The closed form bit error rate (BER) performance analysis is provided. Extensive simulations have been carried out which verified the theoretical analysis.

    nus Repository record for DSP algorithm and system design for UWB communication systems (opens in a new tab) Download file for DSP algorithm and system design for UWB communication systems (opens in a new tab)

  14. Improved Wideband Spectrum Sensing Methods for Cognitive Radio

    … DFT (SDFT) is proposed for use in CR. Then, a sub-Nyquist rate A to D converter is introduced to reduce energy consumption. Finally, a novel multi-resolution PSD estimation based on expectation-maximization algorithm is introduced that can obtain a more accurate PSD within a specified sensing …

    ottawa-retro Repository record for Improved Wideband Spectrum Sensing Methods for Cognitive Radio (opens in a new tab)

  15. Low Latency Compressive Sensing using Multi-Resolution Analysis In Radar Signal Processing

    … speeds and a wider signal bandwidth. The Shannon/Nyquist sampling theorem states, the ADC must sample the signal at a rate two times faster than the signal bandwidth in order to avoid data loss. However, the advances of ADC cannot always meet these demands. Considerable research has been done to …

    carleton Repository record for Low Latency Compressive Sensing using Multi-Resolution Analysis In Radar Signal Processing (opens in a new tab)

  16. Intermodulation in channelized digital ESM receivers

    … Second, by using a narrow bandwidth sub-Nyquist sampling rate with high dynamic range ADCs it is possible to increase the spurious free dynamic range of the digital receiver. The first method is a simple approach but the ability to increase the SFDR is limited. The second method is …

    nps Repository record for Intermodulation in channelized digital ESM receivers (opens in a new tab)

  17. Sparsity-Aware Low-Power ADC Architecture with Advanced Reconstruction Algorithms

    … sensing (CS) technique enables a universal sub-Nyquist sampling of sparse and compressible signals, while still guaranteeing the reliable signal recovery. Its potential lies in the reduced analog-to-digital conversion rate in sampling broadband and/or multi-channel sparse signals, where …

    tamu Repository record for Sparsity-Aware Low-Power ADC Architecture with Advanced Reconstruction Algorithms (opens in a new tab)

  18. Characterization and Linearization of 5G mm-Wave Power Amplifiers Using Reduced-Sampling Observation Receiver

    … a targeted linearization bandwidth, when only sub-Nyquist (aliased) samples are available. A new approach is then devised to apply a direct learning algorithm along with the proposed receiver calibration routine, and thus linearize a millimeter wave power amplifier (PA), driven by a modulated …

    waterloo Repository record for Characterization and Linearization of 5G mm-Wave Power Amplifiers Using Reduced-Sampling Observation Receiver (opens in a new tab)

  19. Compressed Sensing for Imaging Applications

    … theory which allows reconstructing signals using sub-Nyquist measurements. This can significantly reduce the computation re­quired for both image and video whether during acquisition or encoding, especially at the sensor. Compressed sensing works on the assumption of sparsity of the sig­nal in …

    rice Repository record for Compressed Sensing for Imaging Applications (opens in a new tab)

  20. HIGH- SPEED WIRELESS INTERFERENCE SEPARATION BASED ON PHOTONIC DEEP LEARNING ACCELERATORS AND THREE-DIMENSIONAL IMAGE RECONSTRUCTION FOR MEDICAL APPLICATIONS

    … (BSS) to recover wideband signals from their sub-Nyquist samples. With the use of ultra-short optical pulses to obtain statistically representative samples, this method retains important statistical properties of the signals while significantly reducing constraints imposed by analog to digital …

    rowan Repository record for HIGH- SPEED WIRELESS INTERFERENCE SEPARATION BASED ON PHOTONIC DEEP LEARNING ACCELERATORS AND THREE-DIMENSIONAL IMAGE RECONSTRUCTION FOR MEDICAL APPLICATIONS (opens in a new tab)

Page 1 of 3