Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"Sub-Synchronous Oscillations"”.

  1. Consequences on Ringhals Operation from Introduction of Adjacent Offshore Wind Power

    … literature review was conducted which indicated subjects of interest, four key subjects were chosen to study further, namely harmonic emission, sub-synchronous oscillations, behavior during fault and abnormal grid states, and finally, inter-area oscillations. Through further literature analysis, …

    chalmers Repository record for Consequences on Ringhals Operation from Introduction of Adjacent Offshore Wind Power (opens in a new tab)

  2. Sub-Synchronous Oscillation Damping Through Grid-Forming Integration

    … face increasing stability challenges, including sub-synchronous oscillations (SSOs) caused by interactions between grid-following (GFL) converters and weak grids, as well as reduced system inertia. This dissertation investigates how grid-forming (GFM) converter integration can improve damping, …

    cau-kiel Repository record for Sub-Synchronous Oscillation Damping Through Grid-Forming Integration (opens in a new tab)

  3. Multi-Band Subsynchronous Damping Controller for Type III DFIG Wind Turbines with Single Mass and Multi-Mass Rotor Models

    Sub-Synchronous Interactions (SSI), are a family of issues involving the exchange of energy between the generation system and the transmission system, most often found in situations involving series compensated transmission lines. These sub-synchronous oscillations present a hazard to generation …

    sask Repository record for Multi-Band Subsynchronous Damping Controller for Type III DFIG Wind Turbines with Single Mass and Multi-Mass Rotor Models (opens in a new tab)

  4. Oscillatory Stability Monitoring and Control of the Power Grid With a High Penetration of Renewable Energy Sources

    … the stable operation of the power grid. Emerging sub synchronous oscillations (SSOs) in inverter-based resources (IBR) will be the focus of this thesis. Although extensive research has been conducted on SSO incidents related to synchronous generators, HVDC and flexible AC transmission systems …

    auckland-tech Repository record for Oscillatory Stability Monitoring and Control of the Power Grid With a High Penetration of Renewable Energy Sources (opens in a new tab) Embargoed until 2028-10-14

  5. Participation Factor-Based Model Reduction and Partitioning for Accelerating Power System Simulations

    … (IBRs) introduces fast dynamics such as sub-synchronous oscillations (SSOs), fault ride-through events, and stability challenges that are often inadequately captured by traditional phasor-domain simulators. Accurate representation of these dynamics necessitates computationally intensive …

    utk-theses Repository record for Participation Factor-Based Model Reduction and Partitioning for Accelerating Power System Simulations (opens in a new tab)

  6. Experimental Testing of an Electrical Submersible Pump Undergoing Abrasive Slurry Erosion

    The Electrical Submersible Pump (ESP) manufactured by Baker Hughes, model no. WJE-1000 is designed for wells that are expected to have a high content of abrasive solids. It is a mixed flow, tandem compression type pump. Although the erosion of the pump diffuser and impeller stages are significant, …

    tamu Repository record for Experimental Testing of an Electrical Submersible Pump Undergoing Abrasive Slurry Erosion (opens in a new tab)

  7. Sub-synchronous controller interaction (SSCI) of series-compensated DFIG wind farms

    … conditions) to experience unstable resonant oscillations at the subsynchronous frequency range. This thesis studies the sub-synchronous controller interaction (SSCI) of DFIG-based wind-farms with series-compensated transmission lines and suggests a STATCOM solution to damp the resulting …

    chalmers Repository record for Sub-synchronous controller interaction (SSCI) of series-compensated DFIG wind farms (opens in a new tab)

  8. Role of thyristor controlled series compensators in damping sub-synchronous resonance in power systems

    Sub-Synchronous Oscillations (SSOs) pose significant challenges to both conventional and modern power grids. For years, the power industry has relied on Fixed Series Compensators (FSCs) for long-distance AC power transmission, but heavily compensated lines are a major cause for SSOs. Most Thyristor …

    manitoba Repository record for Role of thyristor controlled series compensators in damping sub-synchronous resonance in power systems (opens in a new tab)

  9. Physics-Based and Data-Driven Analytics for Enhanced Planning and Operations in Power Systems with Deep Renewable Penetration

    … is presented to identify the root causes of the sub-synchronous oscillations induced by the wind farm integration. The above problems and proposed solutions are discussed in detail in Section 2 through Section 5. The results of this work can be integrated to address practical problems in modern …

    tamu Repository record for Physics-Based and Data-Driven Analytics for Enhanced Planning and Operations in Power Systems with Deep Renewable Penetration (opens in a new tab)

  10. Stability Analysis of Three-Phase AC Power Systems Based on Measured D-Q Frame Impedances

    … grid synchronization stability issue and sub-synchronous oscillations between grid-tied inverter and its nearby rectifier under weak grid condition are reported and analyzed using characteristic equation of the system. This research proposes a more design oriented analysis approach based …

    vt Repository record for Stability Analysis of Three-Phase AC Power Systems Based on Measured D-Q Frame Impedances (opens in a new tab)

  11. Stability analysis of virtual synchronous machine control strategy in power system

    … In order to deal with this issue, virtual synchronous machine (VSM) control is proposed. Associated with such a solution, it is of great interest to know the impacts of VSM on power system stability, in particular, power system oscillations. Hence, the focus of this doctoral research work …

    birmingham Download PDF for Stability analysis of virtual synchronous machine control strategy in power system (opens in a new tab)

  12. Dynamic Phasor Modeling of Type 3 Wind Farm including Multi-mass and LVRT Effects

    … power electronic switching, control actions, sub-synchronous oscillations, etc., influence the response of wind farms to short circuit conditions, and that makes short circuit modelling of wind farms an interesting, complex, and challenging task. Power electronics-based converters are very …

    sask Repository record for Dynamic Phasor Modeling of Type 3 Wind Farm including Multi-mass and LVRT Effects (opens in a new tab)

  13. Analysis of converter small signal model limitations and oscillation propagation in medium voltage and high voltage DC systems

    … electricity grids of the past with fossil fuel synchronous generation are being replaced with renewable based generation. The increasing penetration of inverter based resources (IBR) has resulted in the modern grid experiencing changes in dynamic characteristics caused by new devices, controls …

    strathclyde Repository record for Analysis of converter small signal model limitations and oscillation propagation in medium voltage and high voltage DC systems (opens in a new tab)