Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 311 for “"Sub-millimeter"”.

  1. A Sub-Millimeter Parallel-Plate Test of Gravity

    … test of the gravitational inverse-square law at sub-millimeter distances. Using a tantalum/titanium torsion balance locked in electrostatic feedback, we performed a null search for deviations from uniformity of the gravitational field of a planar tantalum/aluminum mass. Key innovations include an …

    washington Repository record for A Sub-Millimeter Parallel-Plate Test of Gravity (opens in a new tab)

  2. Sub-millimeter tests of the gravitational inverse-square law

    The Newtonian Law of Universal Gravitation states that the strength of the gravitational force between point test bodies falls as the inverse-square of the distance between them. Recently, novel new theoretical scenario, inspired by string or M theory, predict possible violations of this …

    washington Repository record for Sub-millimeter tests of the gravitational inverse-square law (opens in a new tab)

  3. Sub-millimeter Acoustic Tracking for Medical and VR Applications

    … it is challenging toreliably track motion with millimeter or even sub-millimeter resolution, which hinders theirapplications.My dissertation introduces algorithms and systems to achieve millimeter and sub-millimeteracoustic tracking given the constraints of existing commodity devices. Towards …

    washington Repository record for Sub-millimeter Acoustic Tracking for Medical and VR Applications (opens in a new tab)

  4. Effects of superbubbles on Near-IR and sub-millimeter polarization

    Associations of young, massive stars can collectively energize the interstellar medium through stellar winds and SNII. The energy injected into the ISM can produce large regions of hot, diffuse gas surrounded by a swept-up dense shell of gas, dust and magnetic fields. Such structures are often …

    umn Repository record for Effects of superbubbles on Near-IR and sub-millimeter polarization (opens in a new tab)

  5. Detection of Sub-Millimeter Surface Cracks using Complementary Split-Ring Resonator

    … resonator (CSRR) that is used to detect sub-millimeter surface cracks. The sensing mechanism is based on perturbing the electromagnetic eld around an electrically small resonator, thus initiating a shift in the resonance frequency. Investigation of the current distribution on a CSRR at …

    waterloo Repository record for Detection of Sub-Millimeter Surface Cracks using Complementary Split-Ring Resonator (opens in a new tab)

  6. UNDERSTANDING GALAXY EVOLUTION AND LARGE-SCALE STRUCTURE FORMATION THROUGH (SUB-)MILLIMETER EYES

    … has led to a series of new observations in the (sub-)millimeter, of which I am the PI, that have the potential to lead to truly ground-breaking results in galaxy evolution, and I summarize that progress at the end.

    jhu Repository record for UNDERSTANDING GALAXY EVOLUTION AND LARGE-SCALE STRUCTURE FORMATION THROUGH (SUB-)MILLIMETER EYES (opens in a new tab)

  7. Combustion Behavior Of Sub-Millimeter Sized Oxygenated And N-Alkane Fuel Droplets

    … direct initiation of cool flame combustion for submillimeter-sized higher n-alkane droplets (n-heptane and n-decane) for possible terrestrial experiments without the necessity of radiative extinction as frequently encountered onboard the ISS experiments. It has been found that the dimensionality …

    south-carolina Repository record for Combustion Behavior Of Sub-Millimeter Sized Oxygenated And N-Alkane Fuel Droplets (opens in a new tab)

  8. Development of Microcombustors and Characterization of Confined Sub-Millimeter Laminar Diffusion Flames

    … simple, robust, high endurance, high efficiency sub-millimeter hydrocarbon microscale combustor capable of producing an estimated 400W-cm-3 was built by reducing heterogeneous reactions in the combustor, tailoring the flow pattern of the fuel and oxidizer, and properly insulating the combustor to …

    uiuc Repository record for Development of Microcombustors and Characterization of Confined Sub-Millimeter Laminar Diffusion Flames (opens in a new tab)

  9. Observations of protostellar systems across sub/millimeter wavelengths in nearby molecular clouds

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-03-28 without embargo terms

    uiuc Repository record for Observations of protostellar systems across sub/millimeter wavelengths in nearby molecular clouds (opens in a new tab)

  10. Initiation and detonation in lead azide and silver azide at sub-millimeter geometries

    … charges of both lead azide and silver azide in sub-millimeter geometries has been demonstrated. Results discussed include reaction velocity, observation of an accelerative reaction, observation of retonation waves, and the reaction of a lead azide charge as small as 10 µm in diameter.

    ttu Repository record for Initiation and detonation in lead azide and silver azide at sub-millimeter geometries (opens in a new tab)

  11. Inferring Ice Cloud Properties from Polarized Sub-Millimeter Microwave and Infrared Spaceborne Observations

    … sensitivity and could potentially be filled by sub-millimeter (sub-mm) wave measurements. We present a retrieval algorithm based on the optimal estimation framework designed to retrieve ice cloud properties, which combines sub-mm and infrared (IR) radiometric and polarimetric measurements. …

    tamu Repository record for Inferring Ice Cloud Properties from Polarized Sub-Millimeter Microwave and Infrared Spaceborne Observations (opens in a new tab)

  12. Millimeter and sub-millimeter wave radiometers for atmospheric remote sensing from CubeSat platforms

    To view the abstract, please see the full text of the document.

    colostate Repository record for Millimeter and sub-millimeter wave radiometers for atmospheric remote sensing from CubeSat platforms (opens in a new tab)

  13. Development of differential absorption spectroscopy techniques for a sub-millimeter wave radar system

    … resolution in time and space. In contrast, a sub-millimeter wave radar may be a suitable tool to resolve particle concentrations and velocities. Furthermore, the existence of water absorption lines within the radars frequency range can facilities even water vapor content extraction. In this …

    chalmers Repository record for Development of differential absorption spectroscopy techniques for a sub-millimeter wave radar system (opens in a new tab)

  14. Contribution to imaging focusing techniques using synthetic aperture radars in millimeter and sub-millimeter bands

    [SPA] Esta tesis doctoral se presenta bajo la modalidad de compendio de publicaciones. Las frecuencias de ondas milimétricas (mmW) y terahercios ofrecen características únicas para obtener simultáneamente una buena resolución espacial y penetrabilidad. Los radares de onda continua de frecuencia …

    upc-spain Repository record for Contribution to imaging focusing techniques using synthetic aperture radars in millimeter and sub-millimeter bands (opens in a new tab)

  15. Design and fabrication of sub-millimeter scale gas bearings with tungsten-containing diamond like carbon coatings

    Micro gas bearings of sub millimeter size (diameter of 500µm and length of 300µm) with micron clearances were designed and fabricated through X-ray lithography and Ni electroplating. Details of the fabrication processes for the micro gas bearings are described. Procedures to make X-ray mask and …

    texas Repository record for Design and fabrication of sub-millimeter scale gas bearings with tungsten-containing diamond like carbon coatings (opens in a new tab)

  16. Dynamic range characterization of indium-phosphide double-heterojunction bipolar transistors for ultralinear sub-millimeter wave applications

    Dynamic range characterization of double-heterojunction bipolar transistors is examined. The measurement procedures are detailed, along with a novel procedure for calibrating load-pull measurements using all on-chip calibration standards. The use of all on-chip calibration standards can reduce …

    uiuc Repository record for Dynamic range characterization of indium-phosphide double-heterojunction bipolar transistors for ultralinear sub-millimeter wave applications (opens in a new tab)

  17. THE DESIGN AND STUDY OF THE SUB-MILLIMETER WAVE LENGTH GYROTRON AND FUNDAMENTAL AND SECOND CYCLOTRON HARMONICS

    … high efficiency gyrotrons to operate in the sub-millimeter wavelength region. The gyrotron is to produce pulsed RF power at 670 GHz, with possible application to a novel scheme for detecting concealed radioactive materials. High efficiency is to be achieved by designing a cavity resonator in …

    maryland Repository record for THE DESIGN AND STUDY OF THE SUB-MILLIMETER WAVE LENGTH GYROTRON AND FUNDAMENTAL AND SECOND CYCLOTRON HARMONICS (opens in a new tab)

  18. Design, Fabrication, and Modeling of Indium Phosphide Double-Heterojunction Bipolar Transistors With Sub-Millimeter Wave Cutoff Frequency

    The subject of this work is the design and fabrication of heterojunction bipolar transistors based on InP and the III-V compounds compatible with epitaxial growth on this substrate. Scaling and compositional variations of the transistor material layers are studied with the goal of improving device …

    uiuc Repository record for Design, Fabrication, and Modeling of Indium Phosphide Double-Heterojunction Bipolar Transistors With Sub-Millimeter Wave Cutoff Frequency (opens in a new tab)

Page 1 of 16