Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 41 for “"Sub-synchronous"”.

  1. Sub-Synchronous Oscillation Damping Through Grid-Forming Integration

    … face increasing stability challenges, including sub-synchronous oscillations (SSOs) caused by interactions between grid-following (GFL) converters and weak grids, as well as reduced system inertia. This dissertation investigates how grid-forming (GFM) converter integration can improve damping, …

    cau-kiel Repository record for Sub-Synchronous Oscillation Damping Through Grid-Forming Integration (opens in a new tab)

  2. Sub-synchronous interactions in a wind integrated power system

    … presents a comprehensive procedure to study sub-synchronous interactions in wind integrated power systems effectively and efficiently. The proposed procedure involves a screening phase and a detailed analysis phase. The screening is performed using a frequency scan and the detailed analysis …

    manitoba Repository record for Sub-synchronous interactions in a wind integrated power system (opens in a new tab)

  3. Sub-synchronous controller interaction (SSCI) of series-compensated DFIG wind farms

    … experience unstable resonant oscillations at the subsynchronous frequency range. This thesis studies the sub-synchronous controller interaction (SSCI) of DFIG-based wind-farms with series-compensated transmission lines and suggests a STATCOM solution to damp the resulting oscillations. This is …

    chalmers Repository record for Sub-synchronous controller interaction (SSCI) of series-compensated DFIG wind farms (opens in a new tab)

  4. Role of thyristor controlled series compensators in damping sub-synchronous resonance in power systems

    Sub-Synchronous Oscillations (SSOs) pose significant challenges to both conventional and modern power grids. For years, the power industry has relied on Fixed Series Compensators (FSCs) for long-distance AC power transmission, but heavily compensated lines are a major cause for SSOs. Most Thyristor …

    manitoba Repository record for Role of thyristor controlled series compensators in damping sub-synchronous resonance in power systems (opens in a new tab)

  5. Suppression of Sub-Synchronous Resonance and Torsional Oscillations in Doubly Fed Induction Generator Based Wind Turbines

    … thesis proposes novel approaches for mitigating Sub-Synchronous Resonance (SSR) and torsional vibrations in Doubly Fed Induction Generator (DFIG) based wind turbines. The control approach proposed for SSR mitigation is based on the mechanism of SSR which is identified as being due to the unstable …

    unsw Repository record for Suppression of Sub-Synchronous Resonance and Torsional Oscillations in Doubly Fed Induction Generator Based Wind Turbines (opens in a new tab)

  6. Multi-Band Subsynchronous Damping Controller for Type III DFIG Wind Turbines with Single Mass and Multi-Mass Rotor Models

    Sub-Synchronous Interactions (SSI), are a family of issues involving the exchange of energy between the generation system and the transmission system, most often found in situations involving series compensated transmission lines. These sub-synchronous oscillations present a hazard to generation …

    sask Repository record for Multi-Band Subsynchronous Damping Controller for Type III DFIG Wind Turbines with Single Mass and Multi-Mass Rotor Models (opens in a new tab)

  7. Rotordynamics/discharge water-hammer coupling via seals in pump rotordynamics

    … pump rotordynamics, in order to investigate the sub-synchronous instability problem observed in a field pump. Seal flow-rate perturbations due to eccentricity are calculated from Soulas and San Andres's seal code. A complete transfer function matrix between rotor motion and reaction force due to …

    tamu Repository record for Rotordynamics/discharge water-hammer coupling via seals in pump rotordynamics (opens in a new tab)

  8. Stability analysis of virtual synchronous machine control strategy in power system

    … In order to deal with this issue, virtual synchronous machine (VSM) control is proposed. Associated with such a solution, it is of great interest to know the impacts of VSM on power system stability, in particular, power system oscillations. Hence, the focus of this doctoral research work …

    birmingham Repository record for Stability analysis of virtual synchronous machine control strategy in power system (opens in a new tab)

  9. Dynamic Phasor Modeling of Type 3 Wind Farm including Multi-mass and LVRT Effects

    … power electronic switching, control actions, sub-synchronous oscillations, etc., influence the response of wind farms to short circuit conditions, and that makes short circuit modelling of wind farms an interesting, complex, and challenging task. Power electronics-based converters are very …

    sask Repository record for Dynamic Phasor Modeling of Type 3 Wind Farm including Multi-mass and LVRT Effects (opens in a new tab)

  10. Dynamic behavior of fluid film bearings, applications in the flexible rotor instability analysis

    … of such rotating machinery suffer from excessive sub-synchronous whirl motion when rotating speed of the shaft exceeds “threshold speed of instability”. In this situation the rotor-bearing system experiences sub-synchronous whirling known as “oil whirl/whip” which is the most common type of rotor …

    ubc Repository record for Dynamic behavior of fluid film bearings, applications in the flexible rotor instability analysis (opens in a new tab)

  11. Identification of the fluid induced instability phenomenon in journal bearings

    … Many of such compressors suffer from violent sub-synchronous whirl. If the spin-speed of the rotors exceed the “threshold speed of instability,” the rotor-bearing system experiences sub-synchronous whirling known as oil whirl/whip. For rotors supported on journal bearings, oil whirl is the …

    ubc Repository record for Identification of the fluid induced instability phenomenon in journal bearings (opens in a new tab)

  12. Short circuit modeling of wind turbine generators

    … controllers has led to phenomena such as sub-synchronous control interactions (SSCI) in series compensated Type 3 wind farms which are characterized by non-fundamental frequency oscillations. SSCI affects fault current magnitude significantly and is a crucial factor that cannot be ignored …

    sask Repository record for Short circuit modeling of wind turbine generators (opens in a new tab)

  13. Subsynchronous Resonance

    … However, series capacitors may excite the sub-synchronous resonance and tend to amplify the shaft stress during major network transient event. A power system model is successfully designed and simulated to emulate subsynchronous oscillation. This modeling includes hardware and software …

    calgary Repository record for Subsynchronous Resonance (opens in a new tab)

  14. A frequency-dependent virtual impedance approach to improving stability with grid-forming inverters

    … explores their potential in mitigating Wind Sub-Synchronous Control Oscillations (W-SSCI) in series-compensated systems with Type-3 wind plants when a grid-forming configured battery plant is co-located with the wind plant. A novel frequency-dependent virtual impedance (FDVI) controller is …

    manitoba Repository record for A frequency-dependent virtual impedance approach to improving stability with grid-forming inverters (opens in a new tab)

  15. A Comparison of EMT, Dynamic Phasor, and Traditional Transient Stability Models

    … be used to investigate low frequency (<5Hz) and sub-synchronous frequency (5Hz-60Hz) oscillations. It has major advantages as compared to traditional transient stability method and EMT method. It allows modeling of higher-frequency oscillation possible using time domain simulations, which is not …

    manitoba Repository record for A Comparison of EMT, Dynamic Phasor, and Traditional Transient Stability Models (opens in a new tab)

  16. Experimental Testing of an Electrical Submersible Pump Undergoing Abrasive Slurry Erosion

    The Electrical Submersible Pump (ESP) manufactured by Baker Hughes, model no. WJE-1000 is designed for wells that are expected to have a high content of abrasive solids. It is a mixed flow, tandem compression type pump. Although the erosion of the pump diffuser and impeller stages are significant, …

    tamu Repository record for Experimental Testing of an Electrical Submersible Pump Undergoing Abrasive Slurry Erosion (opens in a new tab)

  17. Consequences on Ringhals Operation from Introduction of Adjacent Offshore Wind Power

    … literature review was conducted which indicated subjects of interest, four key subjects were chosen to study further, namely harmonic emission, sub-synchronous oscillations, behavior during fault and abnormal grid states, and finally, inter-area oscillations. Through further literature analysis, …

    chalmers Repository record for Consequences on Ringhals Operation from Introduction of Adjacent Offshore Wind Power (opens in a new tab)

  18. Development of a Rotordynamic Signal Processing MATLAB Interface and a Two-Disk Rotor Model

    … by this application are slow roll compensation, synchronous and sub-synchronous filtering, and true three dimensional plotting. The verification of this program was done by comparing the results to the ones acquired with Bently Nevada’s “Automated Diagnostics for Rotating Equipment” (ADRE) …

    calpoly Repository record for Development of a Rotordynamic Signal Processing MATLAB Interface and a Two-Disk Rotor Model (opens in a new tab)

  19. Oscillatory Stability Monitoring and Control of the Power Grid With a High Penetration of Renewable Energy Sources

    … the stable operation of the power grid. Emerging sub synchronous oscillations (SSOs) in inverter-based resources (IBR) will be the focus of this thesis. Although extensive research has been conducted on SSO incidents related to synchronous generators, HVDC and flexible AC transmission systems …

    auckland-tech Repository record for Oscillatory Stability Monitoring and Control of the Power Grid With a High Penetration of Renewable Energy Sources (opens in a new tab) Embargoed until 2028-10-14

  20. Modelling and Simulation of DFIG for wind energy applications using PWM converters

    … transmission, and smooth transition between sub-synchronous, synchronous and super-synchronous zones, even during disturbances like a three-phase fault.

    washington Repository record for Modelling and Simulation of DFIG for wind energy applications using PWM converters (opens in a new tab)

Page 1 of 3