Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 151 for “"Subcooling"”.
-
Potential of controlling subcooling in residential air conditioning system
… (RAC) system performance by controlling subcooling. Instead of conventional superheat control at evaporator outlet, condenser subcooling is monitored and controlled and the corresponding effects on vapor-compression system performance as well as the sensitivity of subcooling control to …
-
Subcooling control to maximize efficiency in reversible A/C-H/P systems
Submission published under a 24 month embargo labeled 'Closed Access', the embargo will last until 2024-12-01
-
A study of binary mixture boiling : boiling site density and subcooling boiling
Thesis (M.S.)--Michigan State University. Department of Mechanical Engineering, 1983
-
CO2 TRANSCRITICAL REFRIGERATION WITH MECHANICAL SUBCOOLING: ENERGY EFFICIENCY, DEMAND RESPONSE AND THERMAL STORAGE
… concerns is the use of dedicated mechanical subcooling. Laboratory testing was performed on a transcritical booster system with mechanical subcooling to quantify the system performance with and without the subcooler. Data was used to develop and validate transient models, which in turn were …
-
The Influence of Water Purity and Subcooling on the Minimum Film Boiling Temperature
Made available in DSpace on 2017-07-06T18:42:11Z (GMT). No. of bitstreams: 2 Adler_Mark_R_MS.pdf: 31275816 bytes, checksum: 99c2040effaee627b9d35beede8dc348 (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) Previous issue date: 1979
-
Laser Interferometric Investigation of Microlayer Evaporation for Various Levels of Subcooling and Heat Flux
… flux (8000 Btu/hr ft² - 20,000 Btu/hr ft²) and subcooling (0ºF - 13.5ºF) upon the rates of growth and evaporation, have been studied using laser interferometry and high speed photography through the glass heater surface on which bubbles were nucleated. The results presented indicate that the …
-
Subcooling Effects for Flooding Experiments with Steam and Water in a Large Diameter Vertical Tube
… flooding conditions for varying degrees of subcooling using steam and water. The findings can be used in reactor safety codes to provide an improved model of flooding during accident analysis. The test section is a stainless steel tube which is approximately a 5/16 scale version of a …
-
Pool boiling heat transfer from porous-coated surfaces in FC-72, the effects of subcooling and non-boiling immersion time
Thesis (M.S.)--Michigan State University. Department of Mechanical Engineering, 2005
-
High capacity heat pump development for sanitary hot water production
… On the other hand, for the subcritical systems, subcooling seems to be critical for the heat pump performance when working at high temperature lifts, but there is not any published work that optimizes subcooling in the SHW application for these systems. Therefore, the subcritical cycle should …
-
Potentials for COP increase in vapor compression systems
… systems: work recovery ejectors, condenser subcooling and increase of relative size of heat exchangers (HXs). Regarding work recovery ejectors, experimental results showed that the COP of the ejector system increased between 8.2% and 14.8% when compared to a conventional expansion valve …
-
Pool boiling studies on nanotextured surfaces under highly subcooled conditions
… study. Experiments are carried out under low subcooling (5 °C and 10 °C) and high subcooling conditions (20°C to ~ 38°C). At approximately 38°C, a non-departing bubble configuration is obtained on a bare silicon wafer. Increase in subcooling is found to enhance the critical heat flux (CHF) and …
-
Theoretical and Experimental Analysis of Strategies to Improve the Performance of Transcritical CO2 Condensing Units for Low Temperature Refrigeration Applications
… the work explores the integration of dedicated subcooling strategies as a means to reduce throttling losses and improve system efficiency. A semi-empirical assessment is conducted for a Dedicated Ejector Subcooling (DES) concept, in which compressor waste heat is recovered to drive a thermally …
-
Quiescent Condensation Heat Transfer on Vertical CICNT Structured Superhydrophobic Surfaces
… experimentally investigates the impact of the subcooling magnitude, the carbon-infiltrated carbon nanotube (CICNT) diameter, the time duration of condensation, and amount of non-condensable gases on the nature of dropwise condensation and condensate removal, and heat flux and heat transfer …
-
TEMPERATURE PROFILES IN SUBCOOLED NUCLEATE BOILING
… 100,000 BTU/HRFT2 respectively. Four levels of subcooling were achieved in each series in the range of 0F < 0sub < 105F. Using the superheat-layer thickness as defined by Han and Griffith, results are reported indicating an increase in superheat-layer thickness for an increase in the degree of …
-
Spatial Distribution of Active Sites and Bubble Flux Density
… at different levels of heat flux and subcooling. The results obtained indicated that the active sites were distributed randomly on the heating surface, since the distribution of active sites followed the Poisson distribution.</p> <p>Changes in heat flux and subcooling did not affect …
-
Transient Response Of A Packed Bed For Both Sensible And Latent Thermal Energy Storage
… <p>Both analytical models accommodate ·subcooling and superheating for PCM melting and freezing situations, respectively, as well as supercooling of the PCM in the computer simulation. The significance of subcooling or superheating depends upon the magnitude of the subcooling or …
-
An Experimental Investigation On The Dynamics Of Bubbles Utilizing Refrigerant R134a Under Pressurized Flow Boiling Conditions
… ranged from 167.2 to 672.1 kW/m2 , the inlet subcooling ranged from 0.35°C to 16.55 °C, the system pressure ranged from 621 kPa to 1034 kPa. At high mass flux, the wall heat flux ranged from 329.8 kW/m2 to 744 kW/m2 , the iv inlet subcooling from 0.16°C to 17.21 °C, and the system pressure …
-
Interaction of the Nucleation Phenomena at Adjacent Sites in Nucleate Boiling
… flux (92.21 kW/m2), three different levels of subcooling (0, 6.5, 12°C) were studied and for the higher level of heat flux (192.11 kW/m2), two different levels of subcooling (0, 7.5°C) were studied as well. </p> <p> The cross-spectral density function ·and the crosscorrelation function were …
-
An experimental evaluation of capillary tube-suction line heat exchanger performance with alternative refrigerants HFC-134a and HFC-152a
… effect, commonly referred to as effective subcooling;Capillary tube-suction line heat exchanger performance was experimentally evaluated with alternative refrigerants HFC-134a and HFC-152a. In accomplishing this task, a test facility simulating a household refrigerator was designed and …
Page 1 of 8