Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Surface electromyogram"”.

  1. Wavelet Frequency-Temporal Relative Phase Pattern of the Surface Electromyogram for Investigation of Intramuscular Synchronization

    … The technique was tested on simulated data and surface electromyographic (sEMG) data recorded from upper limb muscles in human subjects as they performed a series of dynamic push and pull tasks. Selected sEMG channel pairs are compared against each other using the WFT-RPP technique to extract …

    queens Repository record for Wavelet Frequency-Temporal Relative Phase Pattern of the Surface Electromyogram for Investigation of Intramuscular Synchronization (opens in a new tab)

  2. Deep Learning Methods for Hand Gesture Recognition via High-Density Surface Electromyogram (HD-sEMG) Signals

    Hand Gesture Recognition (HGR) using surface Electromyogram (sEMG) signals can be considered as one of the most important technologies in making efficient Human Machine Interface (HMI) systems. In particular, sEMG-based hand gesture has been a topic of growing interest for development of assistive …

    concordia Download PDF for Deep Learning Methods for Hand Gesture Recognition via High-Density Surface Electromyogram (HD-sEMG) Signals (opens in a new tab)

  3. Age-Sensitive Features for Detection of Muscle Fatigue using the High-Density Electromyogram

    … the amplitude and spectral characteristics of a surface electromyogram (sEMG), or the variability of torque signals recorded throughout a sustained contraction. However, the behaviour of these parameters with the generation of fatigue depends on a variety of factors. One major factor is age, …

    waterloo Repository record for Age-Sensitive Features for Detection of Muscle Fatigue using the High-Density Electromyogram (opens in a new tab)

  4. Modifying Muscle Properties in a Leading Neuromuscular Model: The Fuglevand Model Revisited

    … them, and observe their effects on the simulated surface electromyogram (EMG) and muscle force. The first was regionalization, the tendency of different motor unit (MU) types to predominantly reside in different regions of the muscle. We found that preferentially placing slow MUs deep and fast MUs …

    calgary Repository record for Modifying Muscle Properties in a Leading Neuromuscular Model: The Fuglevand Model Revisited (opens in a new tab)

  5. Ευφυής λήψη και επεξεργασία βιοσημάτων για την αυτοματοποιημένη αναγνώριση χειρομορφών νοηματικής γλώσσας

    … Sign Language (GSL) recognition using data from surface electromyogram and accelerometer. In this context, the requirements of the acquisition system, such as the type, number and position of the electromyogram electrodes as well as the proposed position of the triaxial accelerometer are …

    greece Repository record for Ευφυής λήψη και επεξεργασία βιοσημάτων για την αυτοματοποιημένη αναγνώριση χειρομορφών νοηματικής γλώσσας (opens in a new tab)

  6. Automatic analysis of surface electromyography of reflexes for central nervous system inhibition during pregnancy

    … (DTR) during pregnancy. We quantified the surface electromyogram (EMG) at the knee and ankle of DTRs in 279 subjects. The signals were analyzed in the time, frequency and time-frequency domains, including normalization to patient characteristics. We uncovered two new phenomena. The first …

    rowan Repository record for Automatic analysis of surface electromyography of reflexes for central nervous system inhibition during pregnancy (opens in a new tab)

  7. Η εκτίμηση της επανεκπαίδευσης των μυών του πυελικού εδάφους σε γυναίκες με ακράτεια ούρων απο προσπάθεια

    … study of their PFM by recording the integrated surface electromyogram (i-sEMG) at rest (1sec) and the maximum contraction (1 and 4 sec). The evaluation of the therapeutic effect of PFMT program was made by using the scales mentioned above, after the first month and when the PFMT program was …

    greece Repository record for Η εκτίμηση της επανεκπαίδευσης των μυών του πυελικού εδάφους σε γυναίκες με ακράτεια ούρων απο προσπάθεια (opens in a new tab)

  8. The effect of the manipulation of blood lactate on the integrated EMG of the vastus lateralis muscle during incremental exercise

    … These results indicate that changes in the surface electromyogram are highly related to changes in power output. However the surface electromyogram changes are not driven by changes in lactate concentration under the conditions of this investigation and may not be a sensitive enough …

    ubc Repository record for The effect of the manipulation of blood lactate on the integrated EMG of the vastus lateralis muscle during incremental exercise (opens in a new tab) Download PDF for The effect of the manipulation of blood lactate on the integrated EMG of the vastus lateralis muscle during incremental exercise (opens in a new tab)

  9. Loss of muscle strength and power in older women and adaptation to resistance training

    … time and frequency-domain characteristics of the surface electromyogram measuredo n the biceps-brachii muscle during constant-force sustained-isometric contractions. Older women responded to the same training programme with a lower increase in strength than the young women. This was accompanied by …

    strathclyde Repository record for Loss of muscle strength and power in older women and adaptation to resistance training (opens in a new tab)

  10. Generalized Force Estimation using Machine Learning and Deep Learning with EMG and Motion Data

    … as robotics, prosthesis control, and sports. The surface electromyogram (EMG) has been widely used for estimating force since the 1950s. However, EMG-force relationship is nonlinear and dynamically changing, and thus the development of an accurate model is a challenging problem for static, and …

    queens Repository record for Generalized Force Estimation using Machine Learning and Deep Learning with EMG and Motion Data (opens in a new tab)

  11. Functionally Adaptive Myosite Selection using conformable HD sEMG electrodes for movement-pattern classification

    … of the forearm, are used for acquisition of surface electromyogram (sEMG) for tran-radial amputee subjects. We propose a novel system, consisting of a hardware and software component. We built the hardware component in the form of a flexible and conformable high-density sEMG array. We tested …

    jhu Repository record for Functionally Adaptive Myosite Selection using conformable HD sEMG electrodes for movement-pattern classification (opens in a new tab)

  12. Investigating neural mechanisms of hand movements in virtual reality

    … system (ANT Neuro). Index finger kinematics and surface Electromyogram (EMG) of the right First Dorsal Interosseous (FDI) muscle were synchronized with the EEG signals to explore the timing of MVF effects on cortical activity. In all four conditions, pronounced decrease in power of beta-band …

    njit Repository record for Investigating neural mechanisms of hand movements in virtual reality (opens in a new tab)

  13. Improving Physical Human-Robot Interaction Using Variable Stiffness Actuators and Electromyography

    … and with lesser collisions between the peg and surface of the hole. Moreover, the average effort required for performing the task significantly reduces in the presence of VSA. We also demonstrate that the VSA can suppress human tremor to an extent and thus enable people with tremor to operate …

    buffalo Repository record for Improving Physical Human-Robot Interaction Using Variable Stiffness Actuators and Electromyography (opens in a new tab)

  14. Cutaneomuscular Reflexes in the Lower Limbs in Man

    … the lateral border of the foot, the plantar surface of the foot and the shank at intensities up to three times perceptual threshold. The reflexes were identified as modulations in the averaged rectified surface electromyogram of the muscles under study. Cutaneomuscular reflexes were recorded …

    glasgow Download PDF for Cutaneomuscular Reflexes in the Lower Limbs in Man (opens in a new tab)

  15. Hybrid Wearable Signal Processing/Learning via Deep Neural Networks

    … (ECG), Photoplethysmogram (PPG), and surface Electromyogram (sEMG), are the most widely non-intrusive monitored signals. Utilizing these widely used non-intrusive signals, the primary emphasis of the proposed dissertation is on the development of advanced Machine Learning (ML), in …

    concordia Download PDF for Hybrid Wearable Signal Processing/Learning via Deep Neural Networks (opens in a new tab)

  16. Neuromuscular dysfunction: characterization and rehabilitation

    … one of which triggered the stimulation by surface electromyogram activity at the first dorsal interosseous while the second group received transcranial magnetic stimulation passively. Results similar to those in Experiment #3 were noted in that the triggered stimulation proved to increase …

    colostate Repository record for Neuromuscular dysfunction: characterization and rehabilitation (opens in a new tab)

  17. Development of a Semantic Model and Synthetic Dataset for Multi-Grasp Affordance Detection for Application to Vision-Based Upper-Limb Prosthetic Grasping

    … methods are predominately myoelectric, where surface electromyogram (sEMG) pattern recognition is used to predict a grasp type for a prosthetic hand to grasp objects. The sEMG patterns also simultaneously detect the action intent of a grasping action and overall movements of the prosthetic …

    waterloo Repository record for Development of a Semantic Model and Synthetic Dataset for Multi-Grasp Affordance Detection for Application to Vision-Based Upper-Limb Prosthetic Grasping (opens in a new tab)

  18. LUMBAR SPINE MOBILIZATION: MEASUREMENT AND EFFECTS

    … muscle was investigated. Ultrasound imaging and surface electromyogram (EMG) were used to measure LM contraction and activity of ES respectively at low isometric contraction (arm lift task). In chapter two, the effect of lumbar mobilization on both LM and ES muscles in healthy subjects was …

    ku Repository record for LUMBAR SPINE MOBILIZATION: MEASUREMENT AND EFFECTS (opens in a new tab)

Page 1 of 2