Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 42 for “"Surge arresters"”

  1. On-Load Tap-Changer with Surge Arresters

    … therefore a safety device so-called surge arrester can be used to protect the OLTC from over-voltages from the grid that may occur and direct them to ground. However, another tap-changer model in Hitachi Energy’s product range lacks this feature due to space limitations within the …

    chalmers Repository record for On-Load Tap-Changer with Surge Arresters (opens in a new tab)

  2. Early Time (E1) High Altitude Electromagnetic Pulse Effects on Lightning Surge Arresters and Trip Coils

    … of this effort are Trip Coils and Lightning Surge Arresters (LSA). Existing data on HEMP, existing standards, and a previous analysis, were used to determine the wave shape, rise time, and pulse width characteristics of the transient to be replicated. The estimated rise time of the conducted …

    unm Repository record for Early Time (E1) High Altitude Electromagnetic Pulse Effects on Lightning Surge Arresters and Trip Coils (opens in a new tab)

  3. The use of surge arresters in parallel for the lightning protection of pole mounted distribution transformers in Eskom.

    … specification of the Eskom distribution class surge arresters was inadequate to offer sufficient lightning protection of the pole mounted transformers. Practical measures were implemented on existing Eskom 11 kV networks in the Glencoe area as part of an Eskom research project to reduce the …

    ukzn Repository record for The use of surge arresters in parallel for the lightning protection of pole mounted distribution transformers in Eskom. (opens in a new tab)

  4. In-service condition monitoring of polymer housed surge arrester within eThekwini Electricity

    … the failures occurring in the family of surge arresters used within EThekwini Electricity, making use of different diagnostic methods, such as leakage current testing (LC), infrared scanning (IR), and partial discharge (PD) measurements. The different diagnostic tests were used to assess …

    dut Repository record for In-service condition monitoring of polymer housed surge arrester within eThekwini Electricity (opens in a new tab)

  5. Protection of transmission lines against switching over voltages

    … be limited to a safe value by the application surge arresters of the metal oxide type. However, surge arresters are expensive, an optimal location for these should be found so as to minimise the number of surge arresters used.

    metu Repository record for Protection of transmission lines against switching over voltages (opens in a new tab)

  6. Overvoltage protection of low voltage systems

    … be limited to a safe value by the application surge arresters of the metal oxide type. However, surge arresters are expensive, an optimal location for these should be found so as to minimise the number of surge arresters used.

    metu Repository record for Overvoltage protection of low voltage systems (opens in a new tab)

  7. Συμβολή στη μελέτη των καθοδικών αλεξικέραυνων

    … Thesis is the study of the metal oxide gapless surge arresters. Surge arresters are installed between phase and earth and protect the electrical installations against overvoltages. Simulations were performed for high voltage transmission lines, in order to compute the arresters failure …

    greece Repository record for Συμβολή στη μελέτη των καθοδικών αλεξικέραυνων (opens in a new tab)

  8. Posicionamento ótimo de para-raios em linhas de transmissão

    … found to improve line performance is the use of surge arresters. However, so that there is not an excessive expenditure of resources, it is necessary to identify the places where such equipment should be installed. Thus, this work proposes the development of a computer application that allows the …

    brazil-ufmg Repository record for Posicionamento ótimo de para-raios em linhas de transmissão (opens in a new tab)

  9. Estudo da absorção de energia de para-raios de ZnO instalados em linhas de transmissão de 138 kV

    Zinc Oxide (ZnO) line arresters are usually installed along overhead transmission lines to improve their lightning performance, particularly in areas with very high soil resistivity and intense lightning activity. For lines rated below 230 kV, this technique has proven to be very effective. …

    brazil-ufmg Repository record for Estudo da absorção de energia de para-raios de ZnO instalados em linhas de transmissão de 138 kV (opens in a new tab)

  10. Análise de desempenho de linhas de transmissão frente a descargas atmosféricas: estudo comparativo de alternativas para melhoria de desempenho de LTs de 230 e 500 kv

    … in counterpoise wires, the installation of surge arresters and underbuilt wires were used. The technical analysis of this work was based on computer simulations using ATP software, which obtained the resulting overvoltages across insulator string of 230 kV and 500 kV transmission lines, …

    brazil-ufmg Repository record for Análise de desempenho de linhas de transmissão frente a descargas atmosféricas: estudo comparativo de alternativas para melhoria de desempenho de LTs de 230 e 500 kv (opens in a new tab)

  11. Cálculo de sobretensões causadas por descargas atmosféricas indiretas em linhas de distribuição aéreas considerando falhas de isolamento

    … distribution line containing transformers, surge arresters, and consumer loads was implemented. Sensitivityanalyses were performed to evaluate the effect of different parameters on the resulting overvoltages, namely the lightning current waveform, the insulator model, the stroke location, …

    brazil-ufmg Repository record for Cálculo de sobretensões causadas por descargas atmosféricas indiretas em linhas de distribuição aéreas considerando falhas de isolamento (opens in a new tab)

  12. Análise de malhas de aterramento compostas por eletrodos verticais profundos em torres de linhas de transmissão

    … to the installation of transmission line surge arresters. For a critical path of the evaluated transmission line, the lightning performance of the deep vertical electrodes seems to be very suitable, in addition to being three times cheaper than the surge arresters’ option. Other advantages …

    brazil-ufmg Repository record for Análise de malhas de aterramento compostas por eletrodos verticais profundos em torres de linhas de transmissão (opens in a new tab)

  13. The use of an auxiliary spark gap placed across the surge arrester of a medium voltage transformer.

    … lower cost alternative to medium voltage line arresters and parallel-connected surge arresters is the use of parallel-connected spark gaps across a metal oxide surge arrester. The function of the spark gap is to protect the transformer when the surge arrester fails. Clearly the breakdown …

    ukzn Repository record for The use of an auxiliary spark gap placed across the surge arrester of a medium voltage transformer. (opens in a new tab)

  14. Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation

    … stress and the performance of different surge protection schemes to mitigate the lightning overvoltages. A full-scale experimental set-up is established to investigate the nature of lightning-initiated flashover faults in MV lines. The flashover voltage of the overhead line is determined …

    aalto Repository record for Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation (opens in a new tab)

  15. Devices Related to Electrical Fast-Transient Protection and Detection

    … to the development of devices such as lightning surge arresters (LSAs). These devices are critical for the protection of the electrical power grid from lightning induced EFT, however electromagnetic pulses (EMP) and other high-power radio frequency (RF) sources can generate much higher frequency …

    unm Repository record for Devices Related to Electrical Fast-Transient Protection and Detection (opens in a new tab)

  16. Effect of valve element characteristics, stray capacitance and voltage harmonics on surge arrester diagnostics

    Metal Oxide Surge Arresters (MOSA) degrade in service under the influence of constant working voltage, internal partial discharges, non-uniform voltage distribution, possible moisture ingress and the occurrence of transient or sustained over-voltage; all of the above result in an increased value of …

    manitoba Repository record for Effect of valve element characteristics, stray capacitance and voltage harmonics on surge arrester diagnostics (opens in a new tab)

  17. Novo modelo eletromagnético no domínio do tempo para cálculo da resposta de sistemas elétricos frente a descargas atmosféricas

    … ionization, the corona effect and the use of surge-arrester in transmission lines. For electrical groundings, the formulation in the time domain characterizes the fundamental parameters, notably concerning the propagation velocity of current and their attenuation along grounding electrodes. …

    brazil-ufmg Repository record for Novo modelo eletromagnético no domínio do tempo para cálculo da resposta de sistemas elétricos frente a descargas atmosféricas (opens in a new tab)

  18. Monitoramento autônomo de para-raios de ZnO

    … state of degradation. In particular, the surge arrester appears as a protective device against overvoltages, preventing surges from reaching assets that are sensitive or of great importance to the system. Thermography and leakage current analysis are the techniques adopted for monitoring …

    brazil-ufmg Repository record for Monitoramento autônomo de para-raios de ZnO (opens in a new tab)

Page 1 of 3