Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 32 for “"Surgical guide"”.
-
Assessment of Surgical Guide Accuracy Utilizing a Digital Workflow
… across an edentulous ridge, and impact of the surgical guide requiring adjustment to fully seat. Furthermore, two methods of post-operative assessment were compared to evaluate consistency of each approach.;Methods: A typical work up for digital implant planning was performed on a sectioned pig …
-
Contact Simulation for Evaluating Patient Specific Surgical Guide Stability
… a novel computational method to quantify guide stability for Patient Specific Instrumentation (PSI) guides. A finite element contact model was used to analyze the final position of PSI guides on a femur across a range of loading parameters representing forces applied by a surgeon during …
-
3D Printed Patient Specific Surgical Guide for Spine Registration During Minimally Invasive Surgery
… automatically generates patient-specific digital guides, which will then be manufactured, to align the patient’s intraoperative and preoperative body position. By aligning the patient’s positions, the 3D printed surgical guide serves as a shared feature between the preoperative digital image and …
-
The effect of surgical guide design and surgeon’s experience on the experience on the accuracy of implant placement.
… preparation, surgeon’s experience and use of a surgical guide. The combined effect of surgical guide design, surgeon’s experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteer surgeons were recruited to …
-
Comparison of DLP printers: surgical guide internal tolerance when designing & manufacturing custom 3D-printed guides for IANB anesthesia
… trial. Due to the unique bite plate, horizontal guide tubes’ angulation and size, full arch span, lingual height of contour exclusion, and no windows; experimentation to determine which DLP 3D printer had the most accurate and precise internal tolerance reproduction and where the highest accuracy …
-
The Effect of the Incorporation of Heavy Metal Zeolites into 3-D Printed Surgical Guide Resin on the Surface Stability of SARS-CoV-2
… heavy metal zeolites integrated into 3-D printed surgical grade resin (SGR). Data were collected using virus plaque assays and luminescent assays to determine the amount of infectious virus present at designated time points. The collected data were analyzed by GraphPad Prism 9 software. When …
-
Influence of metal sleeves in the accuracy of dental implant placement using guided implant surgery
The fabrication of implant surgical guides through stereolithographic 3D printing has become a staple in dental implant guided surgery over the last couple decades. These surgical guides have typically utilized metal sleeves to assist in guidance of the drills during osteotome preparation. The …
-
Accuracy of Implant Placement Comparing a Tissue Level Static Guide vs. Dynamic Navigation Using the X-Mark Protocol on Edentulous Mandibles: A Laboratory Study
… tomography (CBCT), clinicians can have a static surgical guide fabricated to aid in the placement of implants. Dynamic navigation forgoes the step of fabricating a static surgical guide. A new software and protocol have been created for dynamic navigation surgery. Data for the accuracy of this …
-
The Influence of the Digitization Method on the Assessment of Accuracy and Reliability of Implant Placements
… In total, n=40 implants were placed either fully guided (n=20) or free-handed (n=20) in standardized mandible replicas. A static surgical guide was planned for the fully guided surgery group (FG) for an implant at the lower right first molar site and 3D printed. In the free-hand group (FH) the …
-
Accuracy of BLX and BLT guided implants in the edentulous maxilla: an in vivo study
… protocol with a SLA 3D printed mucosa supported surgical guide using a flapless surgical approach with regard to sleeve position, type of implant, and regional location in the maxillary arch. Methods: Nine patients received 4 dental implants utilizing a fully guided, flapless approach with a …
-
Effect of Print Orientation, Storage Conditions, and Time on the Intaglio Surface Accuracy of Additively Manufactured Implant Surgical Guides
… accuracy of additively manufactured (AM) implant surgical guides can be affected by several factors that negatively impact the pre-planned implant position. How the print orientation and storage time and conditions influence manufacturing accuracy remains uncertain. Purpose. The purpose of the …
-
Accuracy, Prosthetic Outcomes, and Patient-related Outcomes with Immediate Loading of 4-Guided Implants Supporting an Unsplinted Maxillary Implant-Retained Overdenture
… of implant placement using a mucosa-supported surgical guide relative to the planned implant position and examine patient-related outcomes associated with immediately-loaded Mx IOD using a single-attachment abutment system. The secondary aim of the study is to examine the prosthetic …
-
STUDIO PILOTA SULL'ACCURATEZZA DELLA METODICA DI IMPLANTOLOGIA ZIGOMATICA GUIDATA
… operational challenge is to perform accurate presurgical diagnostics to plan ZI/PI receptor sites. Further research on guided ZI/PI surgery is highly encouraged, in order to reduce errors and complications in free hand surgeries.The purpose of this study is to introduce a novel protocol for the …
-
The Effect of Surgical Guides on Heat Generation During Guided Implant Surgery: An in Vitro Study
… one implant drill system with and without using surgical drill guides. Temperature elevation during guided surgery was compared to that of conventional drilling in bovine femur specimens. Significant differences in temperature elevation between conventional osteotomy and guided surgical osteotomy …
-
ACCURACY OF SPLINT VS SPLINTLESS TECHNIQUE FOR VIRTUALLY PLANNED ORTHOGNATHIC SURGERY: A VOXEL BASED THREE-DIMENSIONAL ANALYSIS
… planning duration when compared to conventional surgical planning. One of the main concerns regarding virtual planning is the method that is used to transfer the virtual surgical plan into the operation theater. With the many transferring methods proposed, the evidence is confusion regarding the …
-
Comparison of clinically projected and radiographically optimal implant fixture placement.
… with edentulous mandibles scanned with a surgical guide was completed. A total of 218 potential implant sites in 77 patients were evaluated utilizing an implant planning software package (EZ Guide V1.3; Aspen Dental, Burlington, MA). Projections were found to deviate from optimal placement …
-
Comparison of Heat Generated During Twist Drilling Protocol by Guided and Non-Guided Implant Surgery
Introduction: Guided implant surgery is becoming more prevalent among clinicians and is crucial for cases in which there are concerns about the proximity of the implant to vital anatomical structures, esthetic concerns, and the amount/quality of bone available. Surgical guides help with the …
-
Effect of Bone Segementation Data of the Maxilla and Mandible on the Accuracy of Bone-Supported Surgical Guides
… effect on the accuracy of bone-supported guides and whether there is a minimum number of slices that can be identified as being needed to produce a surface model of the mandible and the maxilla that will yield an accurate bone-supported guide. Materials and Methods: Dried human edentulous …
-
Implant prosthodontic rehabilitation in a digital workflow
… 2020. For accurate implant installation, a surgical guide can be used. In Manuscripts 3 and 4, a protocol to create economic and sterilizable surgical guides by ME was described. Comparable results in terms of the trueness of the final implant position to market-available surgical guides …
-
Μελέτη της εφαρμογής ναρθήκων υπολογιστικής καθοδήγησης στην οδοντιατρική αναισθησία
… beam computed tomography (CBCT) with digital surgical guide 3d printing offers the possibility of converting this demanding technique into a standardized and reproducible protocol. The aim of the present thesis was to evaluate the feasibility, accuracy, anesthetic effectiveness, patient …