Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"Susceptibility artifacts"”.
-
FMRI In Patients With Implanted Electrodes: Mitigating Imaging Artifacts
… with implanted electrodes, aiming to mitigate susceptibility artifacts in the resulting fMRI images and thus enhance diagnostic accuracy. Epilepsy is a complex disorder requiring precise identification of epileptogenic zones for successful treatment, particularly in drug-resistant cases. The …
-
Determining optimum imaging parameters for SWIFT: application to superparamagnetic iron oxides and magnetized objects.
… to imaging of superparamagnetic iron oxides. Susceptibility artifacts distort images around metal objects. In SWIFT images the susceptibility artifacts manifest as signal voids surrounded by pileup artifacts. This work develops predictive equations for the pileup artifacts around metallic …
-
Effects of biopsy clips on pharmacokinetic analysis of DCE-MRI data in breast cancer
… or no discomfort from the patient. However, the susceptibility difference will induce significant artifacts in MRI. Currently, radiologists are trained to ignore these distortions in traditional MRI scans. However, with the increased use of quantitative imaging methods such as dynamic contrast …
-
Development Of Multi-Modal Techniques For The Investigation Of Brain Energetics
… recording in the MR scanner with minimal susceptibility artifacts. We apply these techniques to investigate metabolic trends resulting from a whole brain occlusion in the rat and to study neuronal, hemodynamic, and network responses to changes in anesthesia depth. Lastly, we show the first …
-
Examination of susceptibility effects on functional and dynamic magnetic resonance imaging
… field is not present it can cause imaging artifacts and misestimation of tissue structures, flow, and brain function. However, magnetic field inhomogeneity also drives certain contrast mechanisms including blood oxygenation level dependent fMRI. The two projects in this work look at the …
-
Fractal-based magnetic resonance imaging coils for 3T Xenon imaging
… due to low proton density and air-tissue susceptibility artifacts. New imaging techniques using inhaled xenon gas can overcome these challenges at the cost of lower signal to noise ratio. The signal to noise ratio determines reconstructed image quality and is an essential parameter in …
-
Prostate volume delineation and seed localization using a 3-T magnetic resonance spectrometer
… anatomical delineation, but suffer from broad susceptibility artifacts that make determination of seed locations difficult. Proton density-weighted images clearly show seed locations and tissue margins. The selection of a 1 mm slice thickness and a 4 mm interstice gap allowed maximum seed …
-
IMAGING BRAIN FUNCTION AND CEREBRAL BLOOD AND LYMPHATIC VESSELS USING ADVANCED MRI TECHNIQUES
… fMRI method can provide fMRI images with minimal susceptibility artifacts, improving signal detection in regions prone to signal dropouts and distortion. The hemodynamic response functions (HRFs) measured using T2prep BOLD fMRI are compared with the widely used gradient-echo (GRE) and spin-echo …
-
Advancements in Magnetic Resonance Image Guided Radiotherapy
… control over the gradient systems. Banding artifacts appear in the resulting images if these stipulations are violated and intravoxel dephasing approaches an odd multiple of π. Rotation of the radiation therapy gantry also results electromagnetic interference (EMI). The gantry-related EMI …
-
K-t-sub-Nyquist sampled parallel echo planar imaging in MRI
… the spatio-temporal resolution by image artifacts, noise or spatial blurring. In this work, the topic of k-t-sub-Nyquist sampling with time-resolved parallel imaging reconstruction is investigated from two ends: from the theoretical and the practical end. <br><br>A signal and noise …
-
Registration of Total Hip Replacement Implants from Subjects Imaged with 1.5 and 3 Tesla MRI Scanners Using Mavric
… images of a metal implants are susceptible to artifacts. Aim 1 of this study was to register the THAs imaged at 3T to 1.5T images; Aim 2 was to validate that metal susceptibility artifacts increase with field strength.Methods: 21 subjects with a total of 29 hip prosthetics that had coronal …
-
Development of Multi-Shot PARSE MRI Techniques
… as Echo Planar Imaging (EPI) often suffer from artifacts such as signal dropouts, geometric distortions and susceptibility artifacts due to background gradients. Parameter Assessment by Retrieval from Signal Encoding (PARSE) was introduced as a single shot, inverse estimation technique that …
-
Suszeptibilitätsartefakte bei pädiatrischen dentalen konfektionierten Edelstahlkronen in der Magnetresonanztomografie
Die dezidierte Evaluation konfektionierter Edelstahlkronen und ihrer Suszeptibilitätsartefakte in der Magnet-Resonanz-Tomografie (MRT) inklusive der Fragestellung unter welchen Voraussetzungen und in welchem Kontext diese Artefakte zur Notwendigkeit des Entfernens dieser Kronen vor einer MRT- …
-
Neural Correlates of Semantic Memory: from Neuropsychology to Neuroimaging
… (ATL) is a challenging region for fMRI due to susceptibility artifacts, especially at high fields. For these reasons we established an optimized fMRI protocol (described in the second Chapter) by adjusting key acquisition parameters like phase-encoding gradient polarity, slice thickness, echo …
-
Interaktionen zwischen MR-Bildgebung und zahnärztlich - kieferchirurgischen Metallobjekten aus werkstoffkundlicher Sicht
Interaktionen zwischen den im Zuge der zahnärztlichen und kieferchirurgischen Therapie im Mund oder am Schädel fixierten Metallprodukten und der Magnetresonanz-Tomographie sind seit Jahrzehnten Gegenstand verschiedenster Studien sowohl von radiologischen als auch zahnmedizinischen Autoren. Trotzdem …