Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"Sustained-load"”.

  1. Chloride Ingress into Submerged Concrete Under Sustained Load

    … date does not take into account the effects of sustained loading on chloride transport properties. Therefore, the objectives of this study were to investigate the influence of sustained compressive and tensile stresses on chloride ingress into concrete, and ultimately to understand what the …

    ottawa-retro Repository record for Chloride Ingress into Submerged Concrete Under Sustained Load (opens in a new tab)

  2. On Short-term and Sustained-load Analysis of Concrete Frames

    … concrete frames subjected to short term or sustained loads. To check the applicability of the analytical method, two large scale concrete frames were tested under short-term loads and sustained-loads respectively. In addition, data for twenty-two frame tests from other sources has also been …

    mcmaster Repository record for On Short-term and Sustained-load Analysis of Concrete Frames (opens in a new tab)

  3. Time-dependent response of flat plate structures under high sustained load

    … (RC) structures may be exposed to high levels of sustained stresses resulting from errors in construction or design, abnormal loading, and material degradation. Although most RC structures are designed to withstand service level load with a large safety factor, errors may cause failure or …

    missouri Repository record for Time-dependent response of flat plate structures under high sustained load (opens in a new tab)

  4. Freeze-Thaw and Sustained Load Durability of Near Surface Mounted FRP Strengthened Concrete

    … condition (room temperature, freeze-thaw, sustained load, or freeze-thaw under sustained load) are examined. The results indicate no discernable negative impacts on the performance of the grout strengthened members after exposure to freeze-thaw cycles and/or sustained load. The slab strips …

    queens Repository record for Freeze-Thaw and Sustained Load Durability of Near Surface Mounted FRP Strengthened Concrete (opens in a new tab)

  5. Creep Behaviour of Post-Installed Adhesive Anchors under Various Sustained Load Levels and Environmental Exposures

    … creep behaviour of adhesive anchors under sustained tensile loads in combination with different environmental exposures. A comprehensive background and literature review is presented, focusing on various bond stress models for adhesive anchors, factors affecting their bond behavior, and an …

    waterloo Repository record for Creep Behaviour of Post-Installed Adhesive Anchors under Various Sustained Load Levels and Environmental Exposures (opens in a new tab)

  6. Durability of glass-fiber-reinforced polymer composites in an alkaline environment

    … were exposed to alkaline solution with sustained load for six months. The sustained load on each sample was approximately 34.5 MPa or 16--20 percent of their tensile strength. The second experiment exposed both types of GFRP to alkaline solution without load for six months. The final …

    wvu Repository record for Durability of glass-fiber-reinforced polymer composites in an alkaline environment (opens in a new tab)

  7. Combined sustained and short term load testing of geosynthetics

    … elasto-visco-plastic strain response under load. To date, most of the designs are based on the assumption that the loads applied to the structure are of a sustained nature. Field conditions, however, often consist of a sustained load (due to self-weight) and transient loads (due to traffic) …

    strathclyde Repository record for Combined sustained and short term load testing of geosynthetics (opens in a new tab)

  8. The time-dependent response of concrete bond to steel under high sustained loads

    … concrete members being subjected to levels of sustained stresses higher than their expected service loads. These high levels of sustained stress have led to catastrophic RC building collapses around the world. Loading a member greater than 0.75fc' is referred to as high sustained loading and is …

    missouri Repository record for The time-dependent response of concrete bond to steel under high sustained loads (opens in a new tab)

  9. Durability of E-glass fiber reinforced vinyl ester polymer composites with nanoclay in an alkaline environment

    … in alkaline solution of pH 13.2 with and without sustained load. The load was 1335 N or 18.75% of the tensile strength of the composite samples. The aging was evaluated by measuring the reduction in tensile strength after 6 months. Also, absorption of alkaline solution into the plain and nano-GFRP …

    wvu Repository record for Durability of E-glass fiber reinforced vinyl ester polymer composites with nanoclay in an alkaline environment (opens in a new tab)

  10. The effects of environmental aging on the durability of glass/epoxy composites.

    … subjected to a combination of temperature and sustained load at room temperature and at 60°C. The glass transition temperature (Tg), storage modulus, tensile strength, and strain at failure were measured. The fracture surface of samples used in the tensile test were examined using a SEM. …

    wvu Repository record for The effects of environmental aging on the durability of glass/epoxy composites. (opens in a new tab)

  11. Behaviour of CFRP-Prestressed Concrete Beams under Sustained Loading and High-Cycle Fatigue at Low Temperature

    … concrete beams in two studies: (a) under sustained loading at low temperature, and (b) under high-cycle fatigue at low temperature. Seven 13 year old, 4.4 m long precast concrete T beams were tested, of which five were prestressed to various levels with CFRP tendons and two with …

    queens Repository record for Behaviour of CFRP-Prestressed Concrete Beams under Sustained Loading and High-Cycle Fatigue at Low Temperature (opens in a new tab)

  12. Micromechanics of Hydrogen-Induced Crack Initiation in Pipeline Steels and Subcritical Crack Growth

    … of hydrogen on ductile fracture, we model sustained-load cracking in the iron-base superalloy 1N903 at hydrogen pressures at which fracture is governed by plasticity. Through a micromechanics analysis, we quantify the void growth dependence on stress triaxiality and hydrogen-induced …

    uiuc Repository record for Micromechanics of Hydrogen-Induced Crack Initiation in Pipeline Steels and Subcritical Crack Growth (opens in a new tab)

  13. Time-dependent response of reinforced concrete elements near collapse

    … may experience collapse under high levels of sustained gravity load. High levels of load are possibly due to errors in design and construction, material degradation, and abnormal loading. The evolution from local damage to large-scale collapse is time-dependent, and there is a lack of …

    missouri Repository record for Time-dependent response of reinforced concrete elements near collapse (opens in a new tab)

  14. Alkaline durability tests for E-glass/vinyl ester-reinforced polymer with nanoclay

    … (800-lbs), 2225N (500-lbs) and 885N (200-lbs) of sustained load, which were 50%, 31% and 12.5% of the tensile strength, respectively. Time to failure or tensile strength reduction was measured and used to determine durability of the samples in terms of Aging Index, which was proposed as the …

    wvu Repository record for Alkaline durability tests for E-glass/vinyl ester-reinforced polymer with nanoclay (opens in a new tab)

  15. Internal hydrogen-induced subcritical crack growth in stainless steels

    … salt electrolyte. Constant strain rate tests and sustained load tests were performed in air at temperatures from 0 to 50$\sp\circ$C with hydrogen contents up to 41 wt. ppm. The electrical potential drop method with optical calibration was used to monitor the crack growth position, continuously.

    uiuc Repository record for Internal hydrogen-induced subcritical crack growth in stainless steels (opens in a new tab)

  16. Design of Reinforced Concrete Columns

    … design of column cross sections for known axial loads and moments has reached the stage where practical methods give results which agree very closely with tests and with accurate analyses. However considerable uncertainty exists with regard to methods employed to take into account the effects of …

    mcmaster Repository record for Design of Reinforced Concrete Columns (opens in a new tab)

  17. Shear strengthening of reinforced concrete beams with carbon fiber reinforced polymer (CFRP) under fatigue and sustained loading applications

    … laminates and CFRP anchors under fatigue and sustained loading applications. The specimens consisted of 24-in. deep T-beams that were constructed and tested at Phil M. Ferguson Structural Engineering Laboratory at the University of Texas at Austin. The specimens were strengthened in shear with …

    texas Repository record for Shear strengthening of reinforced concrete beams with carbon fiber reinforced polymer (CFRP) under fatigue and sustained loading applications (opens in a new tab)

  18. Multi-scale investigation on durability and long-term behaviour of concrete elements strengthened with CFRP laminates according to the EBR and NSM techniques

    … in flexure with CFRP laminates under sustained load. Four natural environments were selected to induce ageing mainly by carbonation, freeze-thaw cycles, elevated temperatures, and airborne chlorides from seawater. Additionally, a control and a water immersion environment were …

    minho-thes Repository record for Multi-scale investigation on durability and long-term behaviour of concrete elements strengthened with CFRP laminates according to the EBR and NSM techniques (opens in a new tab)

Page 1 of 4