Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"Swept Source Optical Coherence Tomography"”.
-
Spatially multiplexed swept source optical coherence tomography
A novel spectral-domain technique in optical coherence tomography (OCT) using a broadband frequency-tunable laser is presented for high-speed, high-resolution, depth-resolved imaging of tissue microstructure. Spectral domain techniques in OCT have become the focus of investigation in recent times …
-
Towards high-speed Swept Source Optical Coherence Tomography
Optical coherence tomography (OCT) has evolved into an impactful biomedical imaging modality, with swept-source OCT (SS-OCT) emerging as a key technology for pushing axial scan rates from hundreds of Hz to tens of MHz. However, achieving these high speeds introduces critical challenges: (i) …
-
Highly Efficient Spectral Calibration Methods for Swept-Source Optical Coherence Tomography
Recent techniques in optical coherence tomography (OCT) make use of specialized light sources that sweep across a broad optical bandwidth, allowing for longer depth ranges at higher resolutions. The produced light source signal can be described as a gaussian damped sinusoid that non-uniformly …
-
Swept-source optical coherence tomography for ageing assessment of high voltage cellulose insulation
… about the samples than those obtained from optical methods such as microscopy. This could allow a continuous estimation of the operational age of the transformer insulation, beyond only classifying it as belonging to a broad age group. In this thesis, optical coherence tomography (OCT), a …
-
Optimising a Polygon Mirror-based Spectral Filter for Swept Source Optical Coherence Tomography
Optical Coherence Tomography (OCT) is a non-invasive, depth-scan imaging modality with proven applications in medical physics. The benefits of this modality, combined with the range of possible techniques that can be employed, continue to stimulate research and development within this field. One …
-
DEVELOPMENT OF PHASE STABILIZED SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY FOR BIOMEDICAL IMAGING AND SENSING
… various diseases. The developed system utilizes optical coherence tomography (OCT) and is capable of 3D imaging of tissues with near cellular resolution noninvasively. It is also capable of sensing minute changes in tissue refractive index or surface displacement via phase-sensitive measurements. …
-
Dispersion-tuned mode-locking and multi-harmonic operation for swept-source optical coherence tomography
Swept sources are central to optical coherence tomography (OCT), which enabled not only high speeds but also longer imaging depths than in the spectrometer-based OCT methods. Among the various types, dispersion-tuned mode-locked (DTML) lasers offer simplified and cost-effective swept source …
-
Systems and Methods for the Spectral Calibration of Swept Source Optical Coherence Tomography Systems
… to the transition of the state of the art of swept source optical coherence tomography (SS-OCT) systems to a new realm in which the image acquisition speed is improved by an order of magnitude. With the aid of a better quality imaging technology, the speed-up factor will considerably shorten …
-
Measurement of tissue optical properties during mechanical compression using swept source optical coherence tomography
… dog skin during mechanical compression using a swept-source optical coherence tomography (OCT) device built in our lab. The Lorentz-Lorenz rule of mixtures was applied to evaluate the water and protein weight fraction of tissue simultaneously. Results show that the refractive index of skin …
-
Development and Application of High-speed and Wide-field Functional Swept Source Optical Coherence Tomography
Recent advances in optical coherence tomography (OCT) have significantly broadened their utility in biomedical imaging, particularly for the diagnosis and monitoring of vascular-related and microstructural diseases. However, clinical OCT systems remain constrained by limited imaging speed, shallow …
-
Macular Choroidal Thickness and Volume of Eyes With Reticular Pseudodrusen Using Swept-Source Optical Coherence Tomography
Final publication is available at http://www.sciencedirect.com/science/article/pii/S0002939414000488
-
Development of Swept Source Optical Coherence Tomography and Adaptive Optics Scanning Laser Ophthalmoscopy: Improved Imaging Speed and Handheld Applications
<p>Optical coherence tomography (OCT) is a noninvasive three-dimensional interferometric imaging technique capable of achieving micrometer scale resolution. It is now a standard of care in ophthalmology, where it is used to improve the accuracy of early diagnosis, to better understand the source of …
-
Development of Extended-Depth Swept Source Optical Coherence Tomography for Applications in Ophthalmic Imaging of the Anterior and Posterior Eye
<p>Optical coherence tomography (OCT) is a non-invasive optical imaging modality that provides micron-scale resolution of tissue micro-structure over depth ranges of several millimeters. This imaging technique has had a profound effect on the field of ophthalmology, wherein it has become the …
-
Characterization of Two Vernier-Tuned Distributed Bragg Reflector (VT-DBR) Lasers Used in Swept Source Optical Coherence Tomography (SS-OCT)
… wavelength, power, and sweep pattern of the optical output. To validate the laser’s fast tuning response time necessary for its use in SS-OCT, a circuit model of each tuning section is created; each laser section is modeled as a diode with a significant lead inductance. The dynamic …
-
Multimodal photoacoustic remote sensing (PARS) microscopy combined with swept-source optical coherence tomography (SS-OCT) for in-vivo, non-contact, functional and structural ophthalmic imaging applications
… ophthalmic imaging instruments are primarily optical-based, including slit-lamp microscopy, fundus photography, confocal microscopy, scanning laser ophthalmoscopy, and optical coherence tomography (OCT). The development of these imaging instruments has greatly extended our ability to evaluate …
-
Development of a Dual Modality Swept Source Optical Coherence Tomography and Novel Frequency Domain Fluorescence Lifetime Imaging System Using Field Programmable Gate Arrays for Real Time Imaging of Ex-Vivo Human Coronary Artery Atherosclerotic Plaques
… understanding of plaque development in-vivo. Optical coherence tomography (OCT) and fluorescence lifetime imaging (FLIM) are optical imaging modalities that have the potential to extract complimentary morphological and biochemical information, respectively, from plaques without exogenous …
-
On exploring 1600-nm optical coherence tomo-graphy for imaging and analysis of biological tissue
Optical Coherence Tomography (OCT) is a growing field of research in medical imaging, as it allows for imaging of tissue in depth. This research contributes by building a pioneering system for biomedical tissue analysis, using higher wavelengths then currently used, in order to increase penetration …